{"title":"iSMA Range","description":"","products":[{"product_id":"isma-d-pd10c-b1-eu","title":"iSMA-D-PD10C-B1-EU","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eSay hello to the new iSMA HDMI display.\u003cbr\u003e\u003cbr\u003eNiagara 4 has impressive graphics capabilities, and now we have a new solution that will enhance your user interface even further. \u003cbr\u003e\u003cbr\u003eThe iSMA HDMI display is the world's first Niagara 4 BMS touchscreen that works directly with an HDMI connection. It is optimised to work seamlessly with the MAC36NL \u003cbr\u003e\u003cbr\u003eNo IP address required, no kiosk mode and no setup wizard. You plug in the HDMI cable, and the MAC36NL will automatically render the graphics onto the iSMA touchscreen.\u003cbr\u003e\u003cbr\u003eThen you connect the USB cable to the MAC36NL, and the controller will capture all your touch functions.\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003eThis module is fully compatible with any model of MAC36NL, first and second generation.\u003c\/span\u003e\u003cspan data-sheets-userformat='{\"2\":17153,\"3\":{\"1\":0},\"11\":4,\"12\":0,\"17\":1}' data-sheets-value='{\"1\":2,\"2\":\"Distech\"}'\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ch3\u003eDisplay\u003c\/h3\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cul\u003e\n\u003cli\u003eSize 10,1‚Äô‚Äô\u003c\/li\u003e\n\u003cli\u003eAspect Ratio 16:9\u003c\/li\u003e\n\u003cli\u003eResolution 1366x768\u003c\/li\u003e\n\u003cli\u003eContrast 800:1\u003c\/li\u003e\n\u003cli\u003eLuminance 300 nit, up to 800 nit\u003c\/li\u003e\n\u003cli\u003eResponse time 5 ms\u003c\/li\u003e\n\u003cli\u003eActive Area (mm) 222.7x125.2\u003c\/li\u003e\n\u003cli\u003eDisplay Colours 16,7 M (8-bit)\u003c\/li\u003e\n\u003cli\u003eView angle 75\/75\/75\/75\u003c\/li\u003e\n\u003cli\u003e10-point capacitive touch screen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eI\/O Interface\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHDMI\u003c\/li\u003e\n\u003cli\u003eVGA\u003c\/li\u003e\n\u003cli\u003eDVI\u003c\/li\u003e\n\u003cli\u003eI\/O Audio\u003c\/li\u003e\n\u003cli\u003eRJ45-USB for touch input\u003c\/li\u003e\n\u003cli\u003eDC 12-24 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eInterface\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt-in 7 languages - English, French, German, Spanish,\u003cbr\u003eChinese, Italian, Russian\u003c\/li\u003e\n\u003cli\u003eMenu for changing image settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003ePower\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower supply: AC 110-240 V, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003ePanel power input: DC 12 V-24 V\u003c\/li\u003e\n\u003cli\u003ePower consumption: ‚â§ 30 W\u003c\/li\u003e\n\u003cli\u003ePower standby: ‚â§ 1.5 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with VESA\u003c\/li\u003e\n\u003cli\u003eFor embedding\u003c\/li\u003e\n\u003cli\u003eWall Mount\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003ch3\u003eHousing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDimension: 293,6x193,6x48,5 mm (11.560x7.622x1.909\u003cbr\u003ein)\u003c\/li\u003e\n\u003cli\u003eConstruction: Aluminum alloy enclosure, colour black\u003c\/li\u003e\n\u003cli\u003eBezel thickness 3 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ch3\u003eEnvironment\u003c\/h3\u003e\n\u003cspan\u003e\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature: -10¬∞C to 60¬∞C (14¬∞F to 140¬∞F)\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -10¬∞C to 60¬∞C (14¬∞F to 140¬∞F)\u003c\/li\u003e\n\u003cli\u003eOperation humidity: 10% to 80%\u003c\/li\u003e\n\u003cli\u003eStorage humidity: 10% to 90%\u003c\/li\u003e\n\u003cli\u003eIngress Protection Rating: IP65 ‚Äì for front panel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cbr\u003e\u003ca title=\"IO Module Calculator\" href=\"https:\/\/www.innon.com\/pages\/io-calculator\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"\/\/cdn.shopify.com\/s\/files\/1\/1144\/2302\/files\/savetime_iomodulecalculator_befcd269-34ad-4c89-9af0-0abd90d65a73_grande.png?v=1526993647\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-PD-10-TB\" title=\"Documentation \u0026amp; Downloads for iSMA-D-PD10C-B1-EU\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-D-PD10C-B1-EUstyle=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-D-PD10C-B1-EU\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-PD-10-TB\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321528148123,"sku":"iSMA-D-PD10C-B1-EU","price":1000.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/files\/isma-d-pa10-1.png?v=1737467256"},{"product_id":"isma-d-pa10c-b1-eu","title":"iSMA-D-PA10C-B1-EU","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eiSMA-D-PA10C-B1-UK is 10'' Industrial PC Panel with Android 7.1 operating system and UK power adaptor.\u003c\/p\u003e\n\u003cp\u003eIf you are looking for a fast, robust and sharp industrial display then this is it.¬†Set it up in minutes with the¬†help¬†of dedicated apps:\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eAutologin function for any Niagara 4 system: MAC36NL, JACE8000, N4 Supervisor.¬†\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSetup Wizard¬†\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e Kiosk mode.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYou can connect it to iSMA-B-MAC36NL, JACE or other supervisor powered by Niagara 4 to display graphics by the web page from the Niagara system.\u003cbr\u003eAs a Panel PC with Android, it can be also used as User\u003cbr\u003eInterface. You can install a dedicated application that will\u003cbr\u003eallow communication with other devices in BMS\u003cbr\u003ethe system, for example, our Android application designed for connectivity with Niagara station. The Aspect Ratio 16:9 with resolution 1366x768 allows\u003cbr\u003efor displaying graphics clearly. The panel can be built into the wall, it is compatible with VESA. The panel has an extensive menu in 7 languages, in which we can customize the displayed image.\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ch3\u003eDisplay\u003c\/h3\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cul\u003e\n\u003cli\u003eSize 10,1‚Äô‚Äô\u003c\/li\u003e\n\u003cli\u003eAspect Ratio 16:9\u003c\/li\u003e\n\u003cli\u003eResolution 1366x768\u003c\/li\u003e\n\u003cli\u003eContrast 800:1\u003c\/li\u003e\n\u003cli\u003eLuminance 300 nit, up to 800 nit\u003c\/li\u003e\n\u003cli\u003eResponse time 5 ms\u003c\/li\u003e\n\u003cli\u003eActive Area (mm) 222.7x125.2\u003c\/li\u003e\n\u003cli\u003eDisplay colours 16,7 M (8-bit)\u003c\/li\u003e\n\u003cli\u003eView angle 75\/75\/75\/75\u003c\/li\u003e\n\u003cli\u003e10-point capacitive touch screen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-D-PA\/\" title=\"Documentation \u0026amp; Downloads for iSMA-D-PA10C-B1-EU\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-D-PA10C-B1-EU style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-D-PA10C-B1-EU\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-D-PA\/\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321550364827,"sku":"iSMA-D-PA10C-B1-EU","price":1398.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/files\/isma-d-pa10-1.png?v=1737467256"},{"product_id":"isma-b-mac36nl-m-replace","title":"iSMA-B-MAC36NL-M-REPLACE","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAbout the product¬†\u003c\/h5\u003e\n\u003cp\u003eThe¬†iSMA-B-MAC36NL-M-REPLACE is the hardware only version of the MAC36NL-M. It comes \u003cstrong\u003ewithout\u003c\/strong\u003e SD card and no license. This is particularly useful if you¬†need the hardware beforehand and license it only when you need to, thus reducing any risks of ordering a bigger license.¬†\u003c\/p\u003e\n\u003cp\u003eThe iSMA-B-MAC36NL is a compact Master Application Controller with built-in different types of I\/O and operating in Niagara Framework environment. Using the specific local I\/O set 16x UI, 8x AO, 4xDI and 8x DO allows to use the device in different applications. The controller provides control, data logging, alarming, scheduling, integration and visualisation.\u003c\/p\u003e\n\u003cp\u003eTo allow IP connectivity there are 2x Fast Ethernet ports which can operate as two independent ports. Built-in 1x RS485 can be used to expand number of I\/O by connecting MINI or MIX series I\/O modules or to integrate with other subsystems.\u003cbr\u003eiSMA-B-MAC36NL provides rich graphical interface displaying on a standard Web browser or on external display connected to built-in HDMI and USB port (touch-screen support).\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eThere are two more hardware versions of the controller available: standard\u003c\/span\u003e\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003eiSMA-B-MAC36NL\u003c\/strong\u003e\u003cspan\u003e¬†and with the¬†\u003c\/span\u003e\u003cstrong\u003esecond RS485\u003c\/strong\u003e\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003eport\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003eThe Niagara versions available for this controller in the latest\u003cspan\u003e¬†\u003c\/span\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/\"\u003eInstaller\u003c\/a\u003e\u003cspan\u003e¬†\u003c\/span\u003eversion:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNiagara 4.4.73 (not recommended)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.4.92 (not recommended)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.6.96.28 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.7.109.20 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.8.0.110 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.9.0.198 (Use the installer v1.4)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.9.1.30 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.0.154 (Use the installer v1.5)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.1.36 (Use the installer v1.7)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.3.20  (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.11.1.16 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.12.0.156 (Use the installer v1.8)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.12.2.16 (Use the installer v1.9)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.7.42.1\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.9.14.1\u003c\/li\u003e\n\u003cli\u003eNiagara 4.13.2.18\u003c\/li\u003e\n\u003cli\u003eNiagara 4.14.0.162\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBACnet MSTP, Data Recovery Service, Web Service Ports fix and HDMI function are now available for N4.6 and higher.\u003c\/li\u003e\n\u003cli\u003eThe Mbus interface will work only if commissioned with Niagara 4.8.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eFor all new features and improvements, please see the¬†\u003c\/span\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Release_Note\/iSMA-B-MAC36NL_Release_Notes.pdf\" target=\"_blank\"\u003eRelease Notes\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMain features\u003cbr\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-6\" style=\"text-align: justify;\"\u003e\n\u003cstrong\u003e16x Universal Inputs (16UI)\u003c\/strong\u003e\n\u003cp\u003eAll Universal Inputs have 16-bit ADC which support the following types of inputs:\u003cbr\u003eTemperature input supports the following types of sensors:\u003cbr\u003e10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1, Pt1000, Ni1000\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFor sensors Pt1000 and Ni1000 use only 16-bit resolution!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage input 0-10 V DC: input resistance 100 kŒ© accuracy ¬±0,1%, measurement resolution 3 mV @ 12-bit\u003cbr\u003eand 1 mV @ 16-bit\u003c\/li\u003e\n\u003cli\u003eCurrent input 0-20 mA (external resistor¬†200 Œ© required)\u003c\/li\u003e\n\u003cli\u003eResistive input 0-1000 kŒ©: measurement resolution\u003cbr\u003efor 20 kŒ© load: 20 Œ© @ 12-bit and 1 Œ© @ 16-bit\u003c\/li\u003e\n\u003cli\u003eDry contact input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e4x Digital Inputs (4DI)\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eDry contact inputs\u003c\/li\u003e\n\u003cli\u003eFast pulse counter up to 100 Hz saved in SD Card\u003c\/li\u003e\n\u003c\/ul\u003e\n8x Analog Outputs (8AO)\n\u003cp\u003eAll Analog Outputs are equipped with 12-bit ADC provides 10 mV resolution and accuracy less than ¬±0,5%. They support the following output types:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage: 0-10 V DC max. load up to 20 mA\u003c\/li\u003e\n\u003cli\u003ePWM: 0,01 Hz, 0,1 Hz, 1 Hz, 10 Hz, 100 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e8x Digital Outputs (8DO) \u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eRelay output (NO): max. 3 A @ 30 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-6\"\u003e\n\u003cstrong\u003ePlatform\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eMulticore Cortex-A Series ARM Processor\u003c\/li\u003e\n\u003cli\u003e1GB DDR3 SDRAM\u003c\/li\u003e\n\u003cli\u003eRemovable micro-SD card ‚Äì 4 GB\u003cbr\u003e(2 GB system reserved \/ 2 GB user storage)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eCommunication \u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003eRS485 half-duplex, opto-isolated\u003c\/li\u003e\n\u003cli\u003eBaud rate from 2400 to 115200\u003c\/li\u003e\n\u003cli\u003e2x Fast Ethernet (independent)\u003c\/li\u003e\n\u003cli\u003e2x USB (1x OTG, 1x Host)\u003c\/li\u003e\n\u003cli\u003eHDMI type A (standard)\u003c\/li\u003e\n\u003cli\u003eMicro SD card slot\u003c\/li\u003e\n\u003cli\u003eModbus RTU\/ASCII\/IP, BACnet MSTP\/IP, oBIX, SNMP,\u003cbr\u003eLON\/IP, KNX\/IP\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eM-bus interface (on Niagara 4.8)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003ePower supply \u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003e24 V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eHousing\u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003eDimensions: 160x110x62 mm.\u003c\/li\u003e\n\u003cli\u003eConstruction: UL approved,\u003cbr\u003eself-extinguishing plastic (PC\/ABS)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting DIN (DIN EN 50022 norm)\u003c\/li\u003e\n\u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: justify;\"\u003eOperating temperature: -10¬∞C to 50¬∞C\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eStorage temperature: -40¬∞C to 85¬∞C\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eRelative humidity: 5% to 95%, no condensation\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eIngress Protection Rating: IP40 ‚Äì for indoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\n\u003cstrong\u003e\u003c\/strong\u003e¬†\u003c\/h5\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003cdiv\u003e\n\u003ch4\u003eProduct Informations\u003c\/h4\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat is the default IP of the device?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe default IP is : 192.168.1.123.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat Niagara version is needed to connect to this controller?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eAt the moment the¬†default Niagara version is N4.4 (4.4.73.24).\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat should I do if I need to use Niagara 4.4.92.2?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eTo install dist you can either copy the \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/iSMA-MAC36_nre_4.4.92.2\/\"\u003eDIST FILES \u003c\/a\u003eto your¬†\u003cbr\u003e%HOMEPATH%\\Niagara4.4\\sw\\inbox folder and use commisioning wizard, or use Platform‚ÜíDistribution File Installer, choose file and install.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat should I do if I need to use Niagara 4.6 and 4.7?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e¬†Please download the 4.6 and 4.7 update files¬†\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/iSMA-MAC36_nre_4.6%264.7\/\" style=\"color: #0000ff;\"\u003eHERE\u003c\/a\u003e\u003c\/span\u003e, into the zipfile you will find a file named ‚ÄúiSMA_MAC36_files_installer_v1.0.945‚Äù, this will copy for you all the DIST files into the relevant folders.After this procedure you will need to restart the Workplace and commission your MAC36NL with the 4.6 or 4.7 version.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat¬†are the¬†improvements for the MAC36NL¬†with¬†Niagara 4.6 and 4.7?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eWith the release of N4.6 and N4.7 for the MAC36NL you some new features:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eBACnet MSTP\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eData Recovery Service\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWeb Service Port Fix\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\nPlease see read the \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Release_Note\/iSMA-B-MAC36NL_Release_Notes.pdf\"\u003eRelease Notes\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat are the default platform Credentials?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe default credentials are the same as to the Tridium controllers:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003eUser: tridium\u003c\/p\u003e\n\u003cp\u003ePassword:niagara\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat communication networks are available?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eIn this stage the Networks that work are:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e- Modbus RS485\u003c\/p\u003e\n\u003cp\u003e- Modbus TCP\u003c\/p\u003e\n\u003cp\u003e- BACnet TCP\u003c\/p\u003e\n\u003cp\u003e- BACnet MSTP available for version N4.6 and N4.7.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e-¬†Mbus TCP\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e- Niagara Network\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat features are implemented into this controller compared to the Tridium Jace?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe iSMA has the same features as a Tridium N4 controller:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e-Alarm\u003c\/p\u003e\n\u003cp\u003e-Histories\u003c\/p\u003e\n\u003cp\u003e-PX pages (web User Interface pages) HTML 5 web viewing\u003c\/p\u003e\n\u003cp\u003e-Communication with Niagara controllers and Supervisors through Niagara Network\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhen commissioning I see this message: there is no Core software found that can be installed, what should I do?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe core software is installed from the factoryfor version 4.4.73, you just need to press Next.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eAfter using the commissioning wizard to install the Station and modules, I can see into the Application Directory that there are errors regarding the Web Server and I cannot access the controller from the webpage. How do I resolve that error and access the controller through the web page?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eAt this stage the Web server works with the TCP port above 1024, so you will need to go and change the HTTP and HTTPs ports to be above 1024 (ex: HTTP port - 8080, HTTPs port 8443).\u003cspan\u003e¬†After setting this up please restart the station. \u003cstrong\u003eThis issue was resolved in N4.6 and N4.7 release.\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow does the Local IOs work?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe Local IO driver it is still at an early stage and you will need to Download the¬†\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/iSMAIO.zip\" style=\"color: #0000ff; text-decoration: underline;\"\u003eJar file.\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e¬†Put it into the Modules folder and restart the Workbench. Go and find the iSMA IO into the Palette.\u003c\/div\u003e\n\u003cdiv class=\"qs-content\"\u003eInto the Drivers add from the iSMA_IO Palette the iSMA IO Network, after that open the Property Sheet of the Drivers to see the recently added Network. Under it add the Local IO Device and under that add the points from the palette.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow do I change the Universal Input type?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eOpen the property sheet of the UI and you will see the Input type property, by default it is set to Voltage.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow do I change the Analog Output type?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eOpen the property sheet of the AO and you will see the Output type property, by default it is set to Voltage.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow can I use the HDMI function?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe manufacturer is currently testing the HDMI function and will release it in the next software update.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e¬†Do you have a question about this product?\u003c\/strong\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\" target=\"_blank\" title=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-M-REPLACE\" rel=\"noopener\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-M-REPLACE style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-M-REPLACE\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\"\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"position: absolute; left: 146px; top: 631.75px;\" id=\"gtx-trans\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321565569179,"sku":"iSMA-B-MAC36NL-M","price":1466.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-B-MAC36NL-M-600x600_220eb807-ece8-4b87-9485-bc828ee2cb18.png?v=1737467227"},{"product_id":"isma-b-mac36nl-rs-replace","title":"iSMA-B-MAC36NL-RS-REPLACE","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAbout the product¬†\u003c\/h5\u003e\n\u003cp\u003eThe¬†iSMA-B-MAC36NL-RS-REPLACE is the hardware only version of the MAC36NL-RS. It comes \u003cstrong\u003ewithout\u003c\/strong\u003e SD card and no license. This is particularly useful if you¬†need the hardware beforehand and license it only when you need to, thus reducing any risks of ordering a bigger license.¬†\u003c\/p\u003e\n\u003cp\u003eThe iSMA-B-MAC36NL is a compact Master Application Controller with built-in different types of I\/O and operating in Niagara Framework environment. Using the specific local I\/O set 16x UI, 8x AO, 4xDI and 8x DO allows to use the device in different applications. The controller provides control, data logging, alarming, scheduling, integration and visualisation.\u003c\/p\u003e\n\u003cp\u003eTo allow IP connectivity there are 2x Fast Ethernet ports which can operate as two independent ports. Built-in 1x RS485 can be used to expand number of I\/O by connecting MINI or MIX series I\/O modules or to integrate with other subsystems.\u003cbr\u003eiSMA-B-MAC36NL provides rich graphical interface displaying on a standard Web browser or on external display connected to built-in HDMI and USB port (touch-screen support).\u003cbr\u003e\u003cspan\u003eThere are two more hardware versions of the controller available: standard¬†\u003c\/span\u003e\u003cstrong\u003eiSMA-B-MAC36NL\u003c\/strong\u003e\u003cspan\u003e¬†and with¬†\u003c\/span\u003e\u003cstrong\u003eM-Bus interface\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003eThe Niagara versions available for this controller in the latest\u003cspan\u003e¬†\u003c\/span\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/\"\u003eInstaller\u003c\/a\u003e\u003cspan\u003e¬†\u003c\/span\u003eversion:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNiagara 4.4.73 (not recommended)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.4.92 (not recommended)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.6.96.28 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.7.109.20 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.8.0.110 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.9.0.198 (Use the installer v1.4)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.9.1.30 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.0.154 (Use the installer v1.5)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.1.36 (Use the installer v1.7)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.3.20  (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.11.1.16 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.12.0.156 (Use the installer v1.8)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.12.2.16 (Use the installer v1.9)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.7.42.1\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.9.14.1\u003c\/li\u003e\n\u003cli\u003eNiagara 4.13.2.18\u003c\/li\u003e\n\u003cli\u003eNiagara 4.14.0.162\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBACnet MSTP, Data Recovery Service, Web Service Ports fix and HDMI function are now available for N4.6 and higher.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eFor all new features and improvements, please see the¬†\u003c\/span\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Release_Note\/iSMA-B-MAC36NL_Release_Notes.pdf\" target=\"_blank\"\u003eRelease Notes\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMain features\u003cbr\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-6\" style=\"text-align: justify;\"\u003e\n\u003cstrong\u003e16x Universal Inputs (16UI)\u003c\/strong\u003e\n\u003cp\u003eAll Universal Inputs have 16-bit ADC which support the following types of inputs:\u003cbr\u003eTemperature input supports the following types of sensors:\u003cbr\u003e10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1, Pt1000, Ni1000\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFor sensors Pt1000 and Ni1000 use only 16-bit resolution!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage input 0-10 V DC: input resistance 100 kŒ© accuracy ¬±0,1%, measurement resolution 3 mV @ 12-bit\u003cbr\u003eand 1 mV @ 16-bit\u003c\/li\u003e\n\u003cli\u003eCurrent input 0-20 mA (external resistor¬†200 Œ© required)\u003c\/li\u003e\n\u003cli\u003eResistive input 0-1000 kŒ©: measurement resolution\u003cbr\u003efor 20 kŒ© load: 20 Œ© @ 12-bit and 1 Œ© @ 16-bit\u003c\/li\u003e\n\u003cli\u003eDry contact input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e4x Digital Inputs (4DI)\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eDry contact inputs\u003c\/li\u003e\n\u003cli\u003eFast pulse counter up to 100 Hz saved in SD Card\u003c\/li\u003e\n\u003c\/ul\u003e\n8x Analog Outputs (8AO)\n\u003cp\u003eAll Analog Outputs are equipped with 12-bit ADC provides 10 mV resolution and accuracy less than ¬±0,5%. They support the following output types:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage: 0-10 V DC max. load up to 20 mA\u003c\/li\u003e\n\u003cli\u003ePWM: 0,01 Hz, 0,1 Hz, 1 Hz, 10 Hz, 100 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e8x Digital Outputs (8DO) \u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eRelay output (NO): max. 3 A @ 30 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-6\"\u003e\n\u003cstrong\u003ePlatform\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eMulticore Cortex-A Series ARM Processor\u003c\/li\u003e\n\u003cli\u003e1GB DDR3 SDRAM\u003c\/li\u003e\n\u003cli\u003eRemovable micro-SD card ‚Äì 4 GB\u003cbr\u003e(2 GB system reserved \/ 2 GB user storage)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eCommunication \u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003eRS485 half-duplex, opto-isolated\u003c\/li\u003e\n\u003cli\u003eBaud rate from 2400 to 115200\u003c\/li\u003e\n\u003cli\u003e2x Fast Ethernet (independent)\u003c\/li\u003e\n\u003cli\u003e2x USB (1x OTG, 1x Host)\u003c\/li\u003e\n\u003cli\u003eHDMI type A (standard)\u003c\/li\u003e\n\u003cli\u003eMicro SD card slot\u003c\/li\u003e\n\u003cli\u003eModbus RTU\/ASCII\/IP, BACnet MSTP\/IP, oBIX, SNMP,\u003cbr\u003eLON\/IP, KNX\/IP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003ePower supply \u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003e24 V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eHousing\u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003eDimensions: 160x110x62 mm.\u003c\/li\u003e\n\u003cli\u003eConstruction: UL approved,\u003cbr\u003eself-extinguishing plastic (PC\/ABS)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting DIN (DIN EN 50022 norm)\u003c\/li\u003e\n\u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: justify;\"\u003eOperating temperature: -10¬∞C to 50¬∞C\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eStorage temperature: -40¬∞C to 85¬∞C\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eRelative humidity: 5% to 95%, no condensation\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eIngress Protection Rating: IP40 ‚Äì for indoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\n\u003cstrong\u003e\u003c\/strong\u003e¬†\u003c\/h5\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003cdiv\u003e\n\u003ch4\u003eProduct Information\u003c\/h4\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat is the default IP of the device?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe default IP is : 192.168.1.123.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat Niagara version is needed to connect to this controller?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eAt the moment the¬†default Niagara version is N4.4 (4.4.73.24).\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat should I do if I need to use Niagara 4.4.92.2?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eTo install dist you can either copy the \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/iSMA-MAC36_nre_4.4.92.2\/\"\u003eDIST FILES \u003c\/a\u003eto your¬†\u003cbr\u003e%HOMEPATH%\\Niagara4.4\\sw\\inbox folder and use commisioning wizard, or use Platform‚ÜíDistribution File Installer, choose file and install.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat should I do if I need to use Niagara 4.6 and 4.7?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e¬†Please download the 4.6 and 4.7 update files¬†\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/iSMA-MAC36_nre_4.6%264.7\/\" style=\"color: #0000ff;\"\u003eHERE\u003c\/a\u003e\u003c\/span\u003e, into the zipfile you will find a file named ‚ÄúiSMA_MAC36_files_installer_v1.0.945‚Äù, this will copy for you all the DIST files into the relevant folders.After this procedure you will need to restart the Workplace and commission your MAC36NL with the 4.6 or 4.7 version.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat¬†are the¬†improvements for the MAC36NL¬†with¬†Niagara 4.6 and 4.7?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eWith the release of N4.6 and N4.7 for the MAC36NL you some new features:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eBACnet MSTP\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eData Recovery Service\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWeb Service Port Fix\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\nPlease see read the \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Release_Note\/iSMA-B-MAC36NL_Release_Notes.pdf\"\u003eRelease Notes\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat are the default platform Credentials?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe default credentials are the same as to the Tridium controllers:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003eUser: tridium\u003c\/p\u003e\n\u003cp\u003ePassword:niagara\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat communication networks are available?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eIn this stage the Networks that work are:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e- Modbus RS485\u003c\/p\u003e\n\u003cp\u003e- Modbus TCP\u003c\/p\u003e\n\u003cp\u003e- BACnet TCP\u003c\/p\u003e\n\u003cp\u003e- BACnet MSTP available for version N4.6 and N4.7.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e-¬†Mbus TCP\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e- Niagara Network\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat features are implemented into this controller compared to the Tridium Jace?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe iSMA has the same features as a Tridium N4 controller:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e-Alarm\u003c\/p\u003e\n\u003cp\u003e-Histories\u003c\/p\u003e\n\u003cp\u003e-PX pages (web User Interface pages) HTML 5 web viewing\u003c\/p\u003e\n\u003cp\u003e-Communication with Niagara controllers and Supervisors through Niagara Network\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhen commissioning I see this message: there is no Core software found that can be installed, what should I do?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe core software is installed from the factoryfor version 4.4.73, you just need to press Next.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eAfter using the commissioning wizard to install the Station and modules, I can see into the Application Directory that there are errors regarding the Web Server and I cannot access the controller from the webpage. How do I resolve that error and access the controller through the web page?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eAt this stage the Web server works with the TCP port above 1024, so you will need to go and change the HTTP and HTTPs ports to be above 1024 (ex: HTTP port - 8080, HTTPs port 8443).\u003cspan\u003e¬†After setting this up please restart the station. \u003cstrong\u003eThis issue was resolved in N4.6 and N4.7 release.\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow does the Local IOs work?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe Local IO driver it is still at an early stage and you will need to Download the¬†\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/iSMAIO.zip\" style=\"color: #0000ff; text-decoration: underline;\"\u003eJar file.\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e¬†Put it into the Modules folder and restart the Workbench. Go and find the iSMA IO into the Palette.\u003c\/div\u003e\n\u003cdiv class=\"qs-content\"\u003eInto the Drivers add from the iSMA_IO Palette the iSMA IO Network, after that open the Property Sheet of the Drivers to see the recently added Network. Under it add the Local IO Device and under that add the points from the palette.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow do I change the Universal Input type?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eOpen the property sheet of the UI and you will see the Input type property, by default it is set to Voltage.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow do I change the Analog Output type?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eOpen the property sheet of the AO and you will see the Output type property, by default it is set to Voltage.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow can I use the HDMI function?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe manufacturer is currently testing the HDMI function and will release it in the next software update.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\" target=\"_blank\" title=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-RS-REPLACE\" rel=\"noopener\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-RS-REPLACE style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-RS-REPLACE\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\"\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"position: absolute; left: 146px; top: 612.156px;\" id=\"gtx-trans\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321566584987,"sku":"iSMA-B-MAC36NL-RS","price":1432.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-B-MAC36-RS-600x600_5f835ef5-6e6a-43ea-912e-07953edf95fe.png?v=1737467226"},{"product_id":"isma-b-mac36nl-m-ho","title":"iSMA-B-MAC36NL-M-HO","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAbout the product¬†\u003c\/h5\u003e\n\u003cp\u003eThe¬†iSMA-B-MAC36NL-M-HO is the hardware only version of the MAC36NL-M. It comes \u003cstrong\u003ewith\u003c\/strong\u003e SD card and no license. This is particularly useful if you¬†need the hardware beforehand and license it only when you need to, thus reducing any risks of ordering a bigger license.¬†\u003c\/p\u003e\n\u003cp\u003eThe iSMA-B-MAC36NL is a compact Master Application Controller with built-in different types of I\/O and operating in Niagara Framework environment. Using the specific local I\/O set 16x UI, 8x AO, 4xDI and 8x DO allows to use the device in different applications. The controller provides control, data logging, alarming, scheduling, integration and visualisation.\u003c\/p\u003e\n\u003cp\u003eTo allow IP connectivity there are 2x Fast Ethernet ports which can operate as two independent ports. Built-in 1x RS485 can be used to expand number of I\/O by connecting MINI or MIX series I\/O modules or to integrate with other subsystems.\u003cbr\u003eiSMA-B-MAC36NL provides rich graphical interface displaying on a standard Web browser or on external display connected to built-in HDMI and USB port (touch-screen support).\u003cbr\u003e\u003cspan\u003eThere are two more hardware versions of the controller available: standard\u003c\/span\u003e\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003eiSMA-B-MAC36NL\u003c\/strong\u003e\u003cspan\u003e¬†and with the¬†\u003c\/span\u003e\u003cstrong\u003esecond RS485\u003c\/strong\u003e\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003eport\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003eThe Niagara versions available for this controller in the latest \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\/Niagara\/\"\u003eInstaller\u003c\/a\u003e version:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNiagara 4.4.73 (not recommended)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.4.92 (not recommended)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.6.96.28 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.7.109.20 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.8.0.110 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.9.0.198 (Use the installer v1.4)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.9.1.30 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.0.154 (Use the installer v1.5)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.1.36 (Use the installer v1.7)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.3.20  (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.11.1.16 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.12.0.156 (Use the installer v1.8)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.12.2.16 (Use the installer v1.9)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.7.42.1\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.9.14.1\u003c\/li\u003e\n\u003cli\u003eNiagara 4.13.2.18\u003c\/li\u003e\n\u003cli\u003eNiagara 4.14.0.162\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBACnet MSTP, Data Recovery Service, Web Service Ports fix and HDMI function are now available for N4.6 and higher.\u003c\/li\u003e\n\u003cli\u003eThe Mbus interface will work only if commissioned with Niagara 4.8 or above.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eFor all new features and improvements, please see the \u003c\/span\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\/Release_Note\"\u003eRelease Notes\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMain features\u003cbr\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-6\" style=\"text-align: justify;\"\u003e\n\u003cstrong\u003e16x Universal Inputs (16UI)\u003c\/strong\u003e\n\u003cp\u003eAll Universal Inputs have 16-bit ADC which support the following types of inputs:\u003cbr\u003eTemperature input supports the following types of sensors:\u003cbr\u003e10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1, Pt1000, Ni1000\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFor sensors Pt1000 and Ni1000 use only 16-bit resolution!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage input 0-10 V DC: input resistance 100 kŒ© accuracy ¬±0,1%, measurement resolution 3 mV @ 12-bit\u003cbr\u003eand 1 mV @ 16-bit\u003c\/li\u003e\n\u003cli\u003eCurrent input 0-20 mA (external resistor¬†200 Œ© required)\u003c\/li\u003e\n\u003cli\u003eResistive input 0-1000 kŒ©: measurement resolution\u003cbr\u003efor 20 kŒ© load: 20 Œ© @ 12-bit and 1 Œ© @ 16-bit\u003c\/li\u003e\n\u003cli\u003eDry contact input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e4x Digital Inputs (4DI)\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eDry contact inputs\u003c\/li\u003e\n\u003cli\u003eFast pulse counter up to 100 Hz saved in SD Card\u003c\/li\u003e\n\u003c\/ul\u003e\n8x Analog Outputs (8AO)\n\u003cp\u003eAll Analog Outputs are equipped with 12-bit ADC provides 10 mV resolution and accuracy less than ¬±0,5%. They support the following output types:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage: 0-10 V DC max. load up to 20 mA\u003c\/li\u003e\n\u003cli\u003ePWM: 0,01 Hz, 0,1 Hz, 1 Hz, 10 Hz, 100 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e8x Digital Outputs (8DO) \u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eRelay output (NO): max. 3 A @ 30 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-6\"\u003e\n\u003cstrong\u003ePlatform\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eMulticore Cortex-A Series ARM Processor\u003c\/li\u003e\n\u003cli\u003e1GB DDR3 SDRAM\u003c\/li\u003e\n\u003cli\u003eRemovable micro-SD card ‚Äì 4 GB\u003cbr\u003e(2 GB system reserved \/ 2 GB user storage)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eCommunication \u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003eRS485 half-duplex, opto-isolated\u003c\/li\u003e\n\u003cli\u003eBaud rate from 2400 to 115200\u003c\/li\u003e\n\u003cli\u003e2x Fast Ethernet (independent)\u003c\/li\u003e\n\u003cli\u003e2x USB (1x OTG, 1x Host)\u003c\/li\u003e\n\u003cli\u003eHDMI type A (standard)\u003c\/li\u003e\n\u003cli\u003eMicro SD card slot\u003c\/li\u003e\n\u003cli\u003eModbus RTU\/ASCII\/IP, BACnet MSTP\/IP, oBIX, SNMP,\u003cbr\u003eLON\/IP, KNX\/IP\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eM-bus interface (on Niagara 4.8)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003ePower supply \u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003e24 V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eHousing\u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003eDimensions: 160x110x62 mm.\u003c\/li\u003e\n\u003cli\u003eConstruction: UL approved,\u003cbr\u003eself-extinguishing plastic (PC\/ABS)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting DIN (DIN EN 50022 norm)\u003c\/li\u003e\n\u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: justify;\"\u003eOperating temperature: -10¬∞C to 50¬∞C\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eStorage temperature: -40¬∞C to 85¬∞C\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eRelative humidity: 5% to 95%, no condensation\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eIngress Protection Rating: IP40 ‚Äì for indoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\n\u003cstrong\u003e\u003c\/strong\u003e¬†\u003c\/h5\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003cdiv\u003e\n\u003ch4\u003eProduct Informations\u003c\/h4\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat is the default IP of the device?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe default IP is : 192.168.1.123.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat Niagara version is needed to connect to this controller?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eAt the moment the¬†default Niagara version is N4.4 (4.4.73.24).\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat should I do if I need to use Niagara 4.4.92.2?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eTo install dist you can either copy the \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/iSMA-MAC36_nre_4.4.92.2\/\"\u003eDIST FILES \u003c\/a\u003eto your¬†\u003cbr\u003e%HOMEPATH%\\Niagara4.4\\sw\\inbox folder and use commisioning wizard, or use Platform‚ÜíDistribution File Installer, choose file and install.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat should I do if I need to use Niagara 4.6 and 4.7?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e¬†Please download the 4.6 and 4.7 update files¬†\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/iSMA-MAC36_nre_4.6%264.7\/\" style=\"color: #0000ff;\"\u003eHERE\u003c\/a\u003e\u003c\/span\u003e, into the zipfile you will find a file named ‚ÄúiSMA_MAC36_files_installer_v1.0.945‚Äù, this will copy for you all the DIST files into the relevant folders.After this procedure you will need to restart the Workplace and commission your MAC36NL with the 4.6 or 4.7 version.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat¬†are the¬†improvements for the MAC36NL¬†with¬†Niagara 4.6 and 4.7?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eWith the release of N4.6 and N4.7 for the MAC36NL you some new features:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eBACnet MSTP\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eData Recovery Service\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWeb Service Port Fix\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\nPlease see read the \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Release_Note\/iSMA-B-MAC36NL_Release_Notes.pdf\"\u003eRelease Notes\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat are the default platform Credentials?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe default credentials are the same as to the Tridium controllers:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003eUser: tridium\u003c\/p\u003e\n\u003cp\u003ePassword:niagara\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat communication networks are available?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eIn this stage the Networks that work are:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e- Modbus RS485\u003c\/p\u003e\n\u003cp\u003e- Modbus TCP\u003c\/p\u003e\n\u003cp\u003e- BACnet TCP\u003c\/p\u003e\n\u003cp\u003e- BACnet MSTP available for version N4.6 and N4.7.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e-¬†Mbus TCP\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e- Niagara Network\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat features are implemented into this controller compared to the Tridium Jace?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe iSMA has the same features as a Tridium N4 controller:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e-Alarm\u003c\/p\u003e\n\u003cp\u003e-Histories\u003c\/p\u003e\n\u003cp\u003e-PX pages (web User Interface pages) HTML 5 web viewing\u003c\/p\u003e\n\u003cp\u003e-Communication with Niagara controllers and Supervisors through Niagara Network\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhen commissioning I see this message: there is no Core software found that can be installed, what should I do?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe core software is installed from the factoryfor version 4.4.73, you just need to press Next.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eAfter using the commissioning wizard to install the Station and modules, I can see into the Application Directory that there are errors regarding the Web Server and I cannot access the controller from the webpage. How do I resolve that error and access the controller through the web page?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eAt this stage the Web server works with the TCP port above 1024, so you will need to go and change the HTTP and HTTPs ports to be above 1024 (ex: HTTP port - 8080, HTTPs port 8443).\u003cspan\u003e¬†After setting this up please restart the station. \u003cstrong\u003eThis issue was resolved in N4.6 and N4.7 release.\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow does the Local IOs work?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe Local IO driver it is still at an early stage and you will need to Download the¬†\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/iSMAIO.zip\" style=\"color: #0000ff; text-decoration: underline;\"\u003eJar file.\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e¬†Put it into the Modules folder and restart the Workbench. Go and find the iSMA IO into the Palette.\u003c\/div\u003e\n\u003cdiv class=\"qs-content\"\u003eInto the Drivers add from the iSMA_IO Palette the iSMA IO Network, after that open the Property Sheet of the Drivers to see the recently added Network. Under it add the Local IO Device and under that add the points from the palette.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow do I change the Universal Input type?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eOpen the property sheet of the UI and you will see the Input type property, by default it is set to Voltage.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow do I change the Analog Output type?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eOpen the property sheet of the AO and you will see the Output type property, by default it is set to Voltage.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow can I use the HDMI function?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe manufacturer is currently testing the HDMI function and will release it in the next software update.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003ca rel=\"noopener\" title=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-M-HO\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" alt=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-M-HO style=\"\u003e\u003c\/a\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\" title=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-M-HO\"\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"position: absolute; left: 147px; top: 612.156px;\" id=\"gtx-trans\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321571106971,"sku":"iSMA-B-MAC36NL-M;iSMA-B-SD-NL","price":1537.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-B-MAC36NL-M-600x600_f57dc9d2-cf37-41aa-9388-59f001939f21.png?v=1737467225"},{"product_id":"isma-b-mac36nl-m-1250","title":"iSMA-B-MAC36NL-M-1250","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eThe iSMA-B-MAC36NL is Niagara controller with 36 onboard IO and license of 1250 points,¬†one RS485 port and one Mbus port. If more points are needed then you can upgrade in 50 points increment.\u003c\/p\u003e\n\u003cp\u003eThe MAC (Master Application Controller) with built-in different types of I\/O and operating in the Niagara Framework environment. Using the specific local I\/O set 16x UI, 8x AO, 4xDI and 8x DO allow to use the device in different applications. The controller provides control, data logging, alarming, scheduling, integration and visualisation.\u003c\/p\u003e\n\u003cp\u003eTo allow IP connectivity there are 2x Fast Ethernet ports which can operate as two independent ports. Built-in 1x RS485 can be used to expand number of I\/O by connecting MINI or MIX series I\/O modules or to integrate with other subsystems.\u003cbr\u003eiSMA-B-MAC36NL provides rich graphical interface displaying on a standard Web browser or on external display connected to built-in HDMI and USB port (touch-screen support).\u003cbr\u003e\u003cspan\u003eThere are two more hardware versions of the controller available: standard\u003c\/span\u003e\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003eiSMA-B-MAC36NL\u003c\/strong\u003e\u003cspan\u003e¬†and with the¬†\u003c\/span\u003e\u003cstrong\u003esecond RS485\u003c\/strong\u003e\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003eport\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003eThe Niagara versions available for this controller in the latest \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\/Niagara\/\"\u003eInstaller\u003c\/a\u003e version:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNiagara 4.4.73 (not recommended)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.4.92 (not recommended)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.6.96.28 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.7.109.20 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.8.0.110 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.9.0.198 (Use the installer v1.4)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.9.1.30 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.0.154 (Use the installer v1.5)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.1.36 (Use the installer v1.7)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.3.20  (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.11.1.16 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.12.0.156 (Use the installer v1.8)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.12.2.16 (Use the installer v1.9)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.7.42.1\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.9.14.1\u003c\/li\u003e\n\u003cli\u003eNiagara 4.13.2.18\u003c\/li\u003e\n\u003cli\u003eNiagara 4.14.0.162\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBACnet MSTP, Data Recovery Service, Web Service Ports fix and HDMI function are now available for N4.6 and higher.\u003c\/li\u003e\n\u003cli\u003eThe Mbus interface will work only if commissioned with Niagara 4.8 or above.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eFor all new features and improvements, please see the \u003c\/span\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\/Release_Note\"\u003eRelease Notes\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMain features\u003cbr\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-6\" style=\"text-align: justify;\"\u003e\n\u003cstrong\u003e16x Universal Inputs (16UI)\u003c\/strong\u003e\n\u003cp\u003eAll Universal Inputs have 16-bit ADC which support the following types of inputs:\u003cbr\u003eTemperature input supports the following types of sensors:\u003cbr\u003e10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1, Pt1000, Ni1000\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFor sensors Pt1000 and Ni1000 use only 16-bit resolution!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage input 0-10 V DC: input resistance 100 kŒ© accuracy ¬±0,1%, measurement resolution 3 mV @ 12-bit\u003cbr\u003eand 1 mV @ 16-bit\u003c\/li\u003e\n\u003cli\u003eCurrent input 0-20 mA (external resistor¬†200 Œ© required)\u003c\/li\u003e\n\u003cli\u003eResistive input 0-1000 kŒ©: measurement resolution\u003cbr\u003efor 20 kŒ© load: 20 Œ© @ 12-bit and 1 Œ© @ 16-bit\u003c\/li\u003e\n\u003cli\u003eDry contact input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e4x Digital Inputs (4DI)\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eDry contact inputs\u003c\/li\u003e\n\u003cli\u003eFast pulse counter up to 100 Hz saved in SD Card\u003c\/li\u003e\n\u003c\/ul\u003e\n8x Analog Outputs (8AO)\n\u003cp\u003eAll Analog Outputs are equipped with 12-bit ADC provides 10 mV resolution and accuracy less than ¬±0,5%. They support the following output types:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage: 0-10 V DC max. load up to 20 mA\u003c\/li\u003e\n\u003cli\u003ePWM: 0,01 Hz, 0,1 Hz, 1 Hz, 10 Hz, 100 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e8x Digital Outputs (8DO) \u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eRelay output (NO): max. 3 A @ 30 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-6\"\u003e\n\u003cstrong\u003ePlatform\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eMulticore Cortex-A Series ARM Processor\u003c\/li\u003e\n\u003cli\u003e1GB DDR3 SDRAM\u003c\/li\u003e\n\u003cli\u003eRemovable micro-SD card ‚Äì 4 GB\u003cbr\u003e(2 GB system reserved \/ 2 GB user storage)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eCommunication \u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003eRS485 half-duplex, opto-isolated\u003c\/li\u003e\n\u003cli\u003eBaud rate from 2400 to 115200\u003c\/li\u003e\n\u003cli\u003e2x Fast Ethernet (independent)\u003c\/li\u003e\n\u003cli\u003e2x USB (1x OTG, 1x Host)\u003c\/li\u003e\n\u003cli\u003eHDMI type A (standard)\u003c\/li\u003e\n\u003cli\u003eMicro SD card slot\u003c\/li\u003e\n\u003cli\u003eModbus RTU\/ASCII\/IP, BACnet MSTP\/IP, oBIX, SNMP,\u003cbr\u003eLON\/IP, KNX\/IP\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eM-bus interface (on Niagara 4.8)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003ePower supply \u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003e24 V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eHousing\u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003eDimensions: 160x110x62 mm.\u003c\/li\u003e\n\u003cli\u003eConstruction: UL approved,\u003cbr\u003eself-extinguishing plastic (PC\/ABS)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting DIN (DIN EN 50022 norm)\u003c\/li\u003e\n\u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: justify;\"\u003eOperating temperature: -10¬∞C to 50¬∞C\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eStorage temperature: -40¬∞C to 85¬∞C\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eRelative humidity: 5% to 95%, no condensation\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eIngress Protection Rating: IP40 ‚Äì for indoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\n\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/a\u003e¬†\u003c\/h5\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003cdiv\u003e\n\u003ch4\u003eProduct Information¬†\u003c\/h4\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat is the default IP of the device?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe default IP is : 192.168.1.123.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e¬†What Niagara version is needed to connect to this controller?\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003cdiv class=\"qs-content\"\u003eAt the moment the¬†default Niagara version is N4.4 (4.4.73.24).\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat should I do if I need to use Niagara 4.4.92.2?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eTo install dist you can either copy the \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/Precious%20Versions\/iSMA-MAC36_nre_4.4.92.2\/\"\u003eDIST FILES\u003c\/a\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/iSMA-MAC36_nre_4.4.92.2\/\"\u003e \u003c\/a\u003eto your¬†\u003cbr\u003e%HOMEPATH%\\Niagara4.4\\sw\\inbox folder and use commisioning wizard, or use Platform‚ÜíDistribution File Installer, choose file and install.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat should I do if I need to use Niagara 4.6, 4.7 or 4.8?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e¬†Please download the¬†latest update files¬†\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eHERE\u003c\/span\u003e\u003c\/a\u003e, into the zipfile, which contains the DIST files for version 4.6, 4.7 and 4.8. You will find a file named ‚ÄúiSMA_MAC36_files_installer_v1.0.1152.bat‚Äù, this will copy for you all the DIST files into the relevant folders. After this procedure you will need to restart the Workplace and commission your MAC36NL with the 4.6, 4.7 or 4.8 version.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf you need to upgrade to 4.8\u003c\/span\u003e\u003cspan\u003e¬†and¬†\u003c\/span\u003e\u003cspan\u003ethe controller is already running on¬†lower versions (4.4, 4.6¬†or 4.7) the first step you will need\u003c\/span\u003e\u003cspan\u003e¬†to do is¬†\u003c\/span\u003e\u003cspan\u003eto clean the controller¬†by installing the CleanDist file using the Distribution¬†\u003c\/span\u003e\u003cspan\u003eF\u003c\/span\u003e\u003cspan\u003eile¬†\u003c\/span\u003e\u003cspan\u003eI\u003c\/span\u003e\u003cspan\u003enstaller from the controller's platform and after that commission the MAC36NL controller with the 4.8.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat¬†are the¬†improvements for the MAC36NL¬†with¬†Niagara 4.6 and 4.7?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eWith the release of N4.6 and N4.7 for the MAC36NL you some new features:\u003c\/span\u003e\u003c\/p\u003e\n¬†- BACnet MSTP¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† -¬†HDMI\u003cbr\u003e¬†-¬†Data Recovery Service¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬†-¬†¬†\u003cspan\u003eWeb Service Port Fix\u003c\/span\u003e\u003cbr\u003ePlease see read the \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Release_Note\/iSMA-B-MAC36NL_Release_Notes.pdf\"\u003eRelease Notes\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\n\u003cspan style=\"color: #ff0000;\"\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row row-1\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat are the default platform Credentials?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe default credentials are the same as to the Tridium controllers:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003eUser: tridium\u003c\/p\u003e\n\u003cp\u003ePassword:niagara\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat communication networks are available?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eIn this stage the Networks that work are:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e- Modbus RS485\u003c\/p\u003e\n\u003cp\u003e- Modbus TCP\u003c\/p\u003e\n\u003cp\u003e- BACnet TCP\u003c\/p\u003e\n\u003cp\u003e- BACnet MSTP available for version N4.6 and N4.7.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e-¬†Mbus TCP\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e- Niagara Network\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat features are implemented into this controller compared to the Tridium Jace?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe iSMA has the same features as a Tridium N4 controller:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e-Alarm\u003c\/p\u003e\n\u003cp\u003e-Histories\u003c\/p\u003e\n\u003cp\u003e-PX pages (web User Interface pages) HTML 5 web viewing\u003c\/p\u003e\n\u003cp\u003e-Communication with Niagara controllers and Supervisors through Niagara Network\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhen commissioning I see this message: there is no Core software found that can be installed, what should I do?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe core software is installed from the factoryfor version 4.4.73, you just need to press Next.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eAfter using the commissioning wizard to install the Station and modules, I can see into the Application Directory that there are errors regarding the Web Server and I cannot access the controller from the webpage. How do I resolve that error and access the controller through the web page?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eAt this stage the Web server works with the TCP port above 1024, so you will need to go and change the HTTP and HTTPs ports to be above 1024 (ex: HTTP port - 8080, HTTPs port 8443).\u003cspan\u003e¬†After setting this up please restart the station. \u003cstrong\u003eThis issue was resolved in N4.6 and N4.7 release.\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow does the Local IOs work?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe Local IO driver it is still at an early stage and you will need to Download the¬†\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/iSMAIO.zip\" style=\"color: #0000ff; text-decoration: underline;\"\u003eJar file.\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e¬†Put it into the Modules folder and restart the Workbench. Go and find the iSMA IO into the Palette.\u003c\/div\u003e\n\u003cdiv class=\"qs-content\"\u003eInto the Drivers add from the iSMA_IO Palette the iSMA IO Network, after that open the Property Sheet of the Drivers to see the recently added Network. Under it add the Local IO Device and under that add the points from the palette.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow do I change the Universal Input type?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eOpen the property sheet of the UI and you will see the Input type property, by default it is set to Voltage.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow do I change the Analog Output type?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eOpen the property sheet of the AO and you will see the Output type property, by default it is set to Voltage.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow can I use the HDMI function?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003e\n\u003cdiv class=\"qs-content\"\u003eAfter you have commissioned the controller on your N4.6 or N4.7¬† and install the iSMA_HDMI jar file, copy the HDMI service from the iSMA_HDMI pallette to the Service folder and you will need to go to the WEB service and activate the HTTP port and disable HTTPS Only. After you make those settings please reboot the controller.¬†\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e¬†Do you have a question about this product?\u003c\/strong\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\" target=\"_blank\" title=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-M-1250\" rel=\"noopener\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-M-1250 style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-M-1250\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\"\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"position: absolute; left: 143px; top: 572.969px;\" id=\"gtx-trans\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321572352155,"sku":"iSMA-B-MAC36NL-M;iSMA-B-SD-NL","price":3384.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-B-MAC36NL-M-600x600_7cf1c039-f8f9-4e80-bdd4-5f254acbbfe8.png?v=1737467224"},{"product_id":"isma-b-mac36nl-m-500","title":"iSMA-B-MAC36NL-M-500","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eThe iSMA-B-MAC36NL is Niagara controller with 36 onboard IO and license of 500 points,¬†one RS485 port and one Mbus port. If more points are needed then you can upgrade in 50 points increment.\u003c\/p\u003e\n\u003cp\u003eThe MAC (Master Application Controller) with built-in different types of I\/O and operating in the Niagara Framework environment. Using the specific local I\/O set 16x UI, 8x AO, 4xDI and 8x DO allow to use the device in different applications. The controller provides control, data logging, alarming, scheduling, integration and visualisation.\u003c\/p\u003e\n\u003cp\u003eTo allow IP connectivity there are 2x Fast Ethernet ports which can operate as two independent ports. Built-in 1x RS485 can be used to expand number of I\/O by connecting MINI or MIX series I\/O modules or to integrate with other subsystems.\u003cbr\u003eiSMA-B-MAC36NL provides rich graphical interface displaying on a standard Web browser or on external display connected to built-in HDMI and USB port (touch-screen support).\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eThere are two more hardware versions of the controller available: standard\u003c\/span\u003e\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003eiSMA-B-MAC36NL\u003c\/strong\u003e\u003cspan\u003e¬†and with the¬†\u003c\/span\u003e\u003cstrong\u003esecond RS485\u003c\/strong\u003e\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003eport\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003eThe Niagara versions available for this controller in the latest \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\/Niagara\/\"\u003eInstaller\u003c\/a\u003e version:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNiagara 4.4.73 (not recommended)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.4.92 (not recommended)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.6.96.28 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.7.109.20 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.8.0.110 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.9.0.198 (Use the installer v1.4)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.9.1.30 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.0.154 (Use the installer v1.5)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.1.36 (Use the installer v1.7)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.3.20  (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.11.1.16 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.12.0.156 (Use the installer v1.8)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.12.2.16 (Use the installer v1.9)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.7.42.1\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.9.14.1\u003c\/li\u003e\n\u003cli\u003eNiagara 4.13.2.18\u003c\/li\u003e\n\u003cli\u003eNiagara 4.14.0.162\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBACnet MSTP, Data Recovery Service, Web Service Ports fix and HDMI function are now available for N4.6 and higher.\u003c\/li\u003e\n\u003cli\u003eThe Mbus interface will work only if commissioned with Niagara 4.8 or above.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eFor all new features and improvements, please see the \u003c\/span\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\/Release_Note\"\u003eRelease Notes\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMain features\u003cbr\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-6\" style=\"text-align: justify;\"\u003e\n\u003cstrong\u003e16x Universal Inputs (16UI)\u003c\/strong\u003e\n\u003cp\u003eAll Universal Inputs have 16-bit ADC which support the following types of inputs:\u003cbr\u003eTemperature input supports the following types of sensors:\u003cbr\u003e10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1, Pt1000, Ni1000\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFor sensors Pt1000 and Ni1000 use only 16-bit resolution!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage input 0-10 V DC: input resistance 100 kŒ© accuracy ¬±0,1%, measurement resolution 3 mV @ 12-bit\u003cbr\u003eand 1 mV @ 16-bit\u003c\/li\u003e\n\u003cli\u003eCurrent input 0-20 mA (external resistor¬†200 Œ© required)\u003c\/li\u003e\n\u003cli\u003eResistive input 0-1000 kŒ©: measurement resolution\u003cbr\u003efor 20 kŒ© load: 20 Œ© @ 12-bit and 1 Œ© @ 16-bit\u003c\/li\u003e\n\u003cli\u003eDry contact input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e4x Digital Inputs (4DI)\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eDry contact inputs\u003c\/li\u003e\n\u003cli\u003eFast pulse counter up to 100 Hz saved in SD Card\u003c\/li\u003e\n\u003c\/ul\u003e\n8x Analog Outputs (8AO)\n\u003cp\u003eAll Analog Outputs are equipped with 12-bit ADC provides 10 mV resolution and accuracy less than ¬±0,5%. They support the following output types:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage: 0-10 V DC max. load up to 20 mA\u003c\/li\u003e\n\u003cli\u003ePWM: 0,01 Hz, 0,1 Hz, 1 Hz, 10 Hz, 100 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e8x Digital Outputs (8DO) \u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eRelay output (NO): max. 3 A @ 30 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-6\"\u003e\n\u003cstrong\u003ePlatform\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eMulticore Cortex-A Series ARM Processor\u003c\/li\u003e\n\u003cli\u003e1GB DDR3 SDRAM\u003c\/li\u003e\n\u003cli\u003eRemovable micro-SD card ‚Äì 4 GB\u003cbr\u003e(2 GB system reserved \/ 2 GB user storage)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eCommunication \u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003eRS485 half-duplex, opto-isolated\u003c\/li\u003e\n\u003cli\u003eBaud rate from 2400 to 115200\u003c\/li\u003e\n\u003cli\u003e2x Fast Ethernet (independent)\u003c\/li\u003e\n\u003cli\u003e2x USB (1x OTG, 1x Host)\u003c\/li\u003e\n\u003cli\u003eHDMI type A (standard)\u003c\/li\u003e\n\u003cli\u003eMicro SD card slot\u003c\/li\u003e\n\u003cli\u003eModbus RTU\/ASCII\/IP, BACnet MSTP\/IP, oBIX, SNMP,\u003cbr\u003eLON\/IP, KNX\/IP\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eM-bus interface (on Niagara 4.8)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003ePower supply \u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003e24 V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eHousing\u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003eDimensions: 160x110x62 mm.\u003c\/li\u003e\n\u003cli\u003eConstruction: UL approved,\u003cbr\u003eself-extinguishing plastic (PC\/ABS)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting DIN (DIN EN 50022 norm)\u003c\/li\u003e\n\u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: justify;\"\u003eOperating temperature: -10¬∞C to 50¬∞C\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eStorage temperature: -40¬∞C to 85¬∞C\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eRelative humidity: 5% to 95%, no condensation\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eIngress Protection Rating: IP40 ‚Äì for indoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\n\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/\"\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/a\u003eProduct Information\u003c\/h5\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003cdiv\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat is the default IP of the device?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe default IP is : 192.168.1.123.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat Niagara version is needed to connect to this controller?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eAt the moment the¬†default Niagara version is N4.4 (4.4.73.24).\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat should I do if I need to use Niagara 4.4.92.2?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eTo install dist you can either copy the \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/Precious%20Versions\/iSMA-MAC36_nre_4.4.92.2\/\"\u003eDIST FILES\u003c\/a\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/iSMA-MAC36_nre_4.4.92.2\/\"\u003e \u003c\/a\u003eto your¬†\u003cbr\u003e%HOMEPATH%\\Niagara4.4\\sw\\inbox folder and use commisioning wizard, or use Platform‚ÜíDistribution File Installer, choose file and install.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat should I do if I need to use Niagara 4.6, 4.7 or 4.8?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e¬†Please download the¬†latest update files¬†\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eHERE\u003c\/span\u003e\u003c\/a\u003e, into the zipfile, which contains the DIST files for version 4.6, 4.7 and 4.8. You will find a file named ‚ÄúiSMA_MAC36_files_installer_v1.0.1152.bat‚Äù, this will copy for you all the DIST files into the relevant folders. After this procedure you will need to restart the Workplace and commission your MAC36NL with the 4.6, 4.7 or 4.8 version.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf you need to upgrade to 4.8\u003c\/span\u003e\u003cspan\u003e¬†and¬†\u003c\/span\u003e\u003cspan\u003ethe controller is already running on¬†lower versions (4.4, 4.6¬†or 4.7) the first step you will need\u003c\/span\u003e\u003cspan\u003e¬†to do is¬†\u003c\/span\u003e\u003cspan\u003eto clean the controller¬†by installing the CleanDist file using the Distribution¬†\u003c\/span\u003e\u003cspan\u003eF\u003c\/span\u003e\u003cspan\u003eile¬†\u003c\/span\u003e\u003cspan\u003eI\u003c\/span\u003e\u003cspan\u003enstaller from the controller's platform and after that commission the MAC36NL controller with the 4.8.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat¬†are the¬†improvements for the MAC36NL¬†with¬†Niagara 4.6 and 4.7?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eWith the release of N4.6 and N4.7 for the MAC36NL you some new features:\u003c\/span\u003e\u003c\/p\u003e\n¬†- BACnet MSTP¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† -¬†HDMI\u003cbr\u003e¬†-¬†Data Recovery Service¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬†-¬†¬†\u003cspan\u003eWeb Service Port Fix\u003c\/span\u003e\u003cbr\u003ePlease see read the \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Release_Note\/iSMA-B-MAC36NL_Release_Notes.pdf\"\u003eRelease Notes\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\n\u003cspan style=\"color: #ff0000;\"\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row row-1\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat are the default platform Credentials?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe default credentials are the same as to the Tridium controllers:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003eUser: tridium\u003c\/p\u003e\n\u003cp\u003ePassword:niagara\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat communication networks are available?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eIn this stage the Networks that work are:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e- Modbus RS485\u003c\/p\u003e\n\u003cp\u003e- Modbus TCP\u003c\/p\u003e\n\u003cp\u003e- BACnet TCP\u003c\/p\u003e\n\u003cp\u003e- BACnet MSTP available for version N4.6 and N4.7.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e-¬†Mbus TCP\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e- Niagara Network\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat features are implemented into this controller compared to the Tridium Jace?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe iSMA has the same features as a Tridium N4 controller:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e-Alarm\u003c\/p\u003e\n\u003cp\u003e-Histories\u003c\/p\u003e\n\u003cp\u003e-PX pages (web User Interface pages) HTML 5 web viewing\u003c\/p\u003e\n\u003cp\u003e-Communication with Niagara controllers and Supervisors through Niagara Network\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhen commissioning I see this message: there is no Core software found that can be installed, what should I do?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe core software is installed from the factoryfor version 4.4.73, you just need to press Next.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eAfter using the commissioning wizard to install the Station and modules, I can see into the Application Directory that there are errors regarding the Web Server and I cannot access the controller from the webpage. How do I resolve that error and access the controller through the web page?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eAt this stage the Web server works with the TCP port above 1024, so you will need to go and change the HTTP and HTTPs ports to be above 1024 (ex: HTTP port - 8080, HTTPs port 8443).\u003cspan\u003e¬†After setting this up please restart the station. \u003cstrong\u003eThis issue was resolved in N4.6 and N4.7 release.\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow does the Local IOs work?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe Local IO driver it is still at an early stage and you will need to Download the¬†\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/iSMAIO.zip\" style=\"color: #0000ff; text-decoration: underline;\"\u003eJar file.\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e¬†Put it into the Modules folder and restart the Workbench. Go and find the iSMA IO into the Palette.\u003c\/div\u003e\n\u003cdiv class=\"qs-content\"\u003eInto the Drivers add from the iSMA_IO Palette the iSMA IO Network, after that open the Property Sheet of the Drivers to see the recently added Network. Under it add the Local IO Device and under that add the points from the palette.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow do I change the Universal Input type?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eOpen the property sheet of the UI and you will see the Input type property, by default it is set to Voltage.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow do I change the Analog Output type?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eOpen the property sheet of the AO and you will see the Output type property, by default it is set to Voltage.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow can I use the HDMI function?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003e\n\u003cdiv class=\"qs-content\"\u003eAfter you have commissioned the controller on your N4.6 or N4.7¬† and install the iSMA_HDMI jar file, copy the HDMI service from the iSMA_HDMI pallette to the Service folder and you will need to go to the WEB service and activate the HTTP port and disable HTTPS Only. After you make those settings please reboot the controller.¬†\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\" target=\"_blank\" title=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-M-500\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" alt=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-M-500‚Äù style=\"\u003e\u003c\/a\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\" title=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-M-500\"\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"gtx-trans\" style=\"position: absolute; left: 147px; top: 544.562px;\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321573499035,"sku":"iSMA-B-MAC36NL-M;iSMA-B-SD-NL","price":2672.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-B-MAC36NL-M-600x600_9035ab43-53af-4a4c-9f5f-236eac6f82d3.png?v=1737467223"},{"product_id":"isma-b-mac36nl-m-300","title":"iSMA-B-MAC36NL-M-300","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eThe iSMA-B-MAC36NL is Niagara controller with 36 onboard IO and license of 300 points,¬†one RS485 port and one Mbus port. If more points are needed then you can upgrade in 50 points increment.\u003c\/p\u003e\n\u003cp\u003eThe MAC (Master Application Controller) with built-in different types of I\/O and operating in the Niagara Framework environment. Using the specific local I\/O set 16x UI, 8x AO, 4xDI and 8x DO allow to use the device in different applications. The controller provides control, data logging, alarming, scheduling, integration and visualisation.\u003c\/p\u003e\n\u003cp\u003eTo allow IP connectivity there are 2x Fast Ethernet ports which can operate as two independent ports. Built-in 1x RS485 can be used to expand number of I\/O by connecting MINI or MIX series I\/O modules or to integrate with other subsystems.\u003cbr\u003eiSMA-B-MAC36NL provides rich graphical interface displaying on a standard Web browser or on external display connected to built-in HDMI and USB port (touch-screen support).\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eThere are two more hardware versions of the controller available: standard\u003c\/span\u003e\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003eiSMA-B-MAC36NL\u003c\/strong\u003e\u003cspan\u003e¬†and with the¬†\u003c\/span\u003e\u003cstrong\u003esecond RS485\u003c\/strong\u003e\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003eport\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003eThe Niagara versions available for this controller in the latest \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\/Niagara\/\"\u003eInstaller\u003c\/a\u003e version:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNiagara 4.4.73 (not recommended)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.4.92 (not recommended)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.6.96.28 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.7.109.20 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.8.0.110 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.9.0.198 (Use the installer v1.4)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.9.1.30 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.0.154 (Use the installer v1.5)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.1.36 (Use the installer v1.7)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.3.20  (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.11.1.16 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.12.0.156 (Use the installer v1.8)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.12.2.16 (Use the installer v1.9)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.7.42.1\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.9.14.1\u003c\/li\u003e\n\u003cli\u003eNiagara 4.13.2.18\u003c\/li\u003e\n\u003cli\u003eNiagara 4.14.0.162\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBACnet MSTP, Data Recovery Service, Web Service Ports fix and HDMI function are now available for N4.6 and higher.\u003c\/li\u003e\n\u003cli\u003eThe Mbus interface will work only if commissioned with Niagara 4.8 or above.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eFor all new features and improvements, please see the \u003c\/span\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\/Release_Note\"\u003eRelease Notes\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMain features\u003cbr\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv style=\"text-align: justify;\" class=\"col-sm-6\"\u003e\n\u003cstrong\u003e16x Universal Inputs (16UI)\u003c\/strong\u003e\n\u003cp\u003eAll Universal Inputs have 16-bit ADC which support the following types of inputs:\u003cbr\u003eTemperature input supports the following types of sensors:\u003cbr\u003e10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1, Pt1000, Ni1000\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFor sensors Pt1000 and Ni1000 use only 16-bit resolution!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage input 0-10 V DC: input resistance 100 kŒ© accuracy ¬±0,1%, measurement resolution 3 mV @ 12-bit\u003cbr\u003eand 1 mV @ 16-bit\u003c\/li\u003e\n\u003cli\u003eCurrent input 0-20 mA (external resistor¬†200 Œ© required)\u003c\/li\u003e\n\u003cli\u003eResistive input 0-1000 kŒ©: measurement resolution\u003cbr\u003efor 20 kŒ© load: 20 Œ© @ 12-bit and 1 Œ© @ 16-bit\u003c\/li\u003e\n\u003cli\u003eDry contact input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e4x Digital Inputs (4DI)\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eDry contact inputs\u003c\/li\u003e\n\u003cli\u003eFast pulse counter up to 100 Hz saved in SD Card\u003c\/li\u003e\n\u003c\/ul\u003e\n8x Analog Outputs (8AO)\n\u003cp\u003eAll Analog Outputs are equipped with 12-bit ADC provides 10 mV resolution and accuracy less than ¬±0,5%. They support the following output types:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage: 0-10 V DC max. load up to 20 mA\u003c\/li\u003e\n\u003cli\u003ePWM: 0,01 Hz, 0,1 Hz, 1 Hz, 10 Hz, 100 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e8x Digital Outputs (8DO) \u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eRelay output (NO): max. 3 A @ 30 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-6\"\u003e\n\u003cstrong\u003ePlatform\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eMulticore Cortex-A Series ARM Processor\u003c\/li\u003e\n\u003cli\u003e1GB DDR3 SDRAM\u003c\/li\u003e\n\u003cli\u003eRemovable micro-SD card ‚Äì 4 GB\u003cbr\u003e(2 GB system reserved \/ 2 GB user storage)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eCommunication \u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003eRS485 half-duplex, opto-isolated\u003c\/li\u003e\n\u003cli\u003eBaud rate from 2400 to 115200\u003c\/li\u003e\n\u003cli\u003e2x Fast Ethernet (independent)\u003c\/li\u003e\n\u003cli\u003e2x USB (1x OTG, 1x Host)\u003c\/li\u003e\n\u003cli\u003eHDMI type A (standard)\u003c\/li\u003e\n\u003cli\u003eMicro SD card slot\u003c\/li\u003e\n\u003cli\u003eModbus RTU\/ASCII\/IP, BACnet MSTP\/IP, oBIX, SNMP,\u003cbr\u003eLON\/IP, KNX\/IP\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eM-bus interface (on Niagara 4.8)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003ePower supply \u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003e24 V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eHousing\u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003eDimensions: 160x110x62 mm.\u003c\/li\u003e\n\u003cli\u003eConstruction: UL approved,\u003cbr\u003eself-extinguishing plastic (PC\/ABS)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting DIN (DIN EN 50022 norm)\u003c\/li\u003e\n\u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: justify;\"\u003eOperating temperature: -10¬∞C to 50¬∞C\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eStorage temperature: -40¬∞C to 85¬∞C\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eRelative humidity: 5% to 95%, no condensation\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eIngress Protection Rating: IP40 ‚Äì for indoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\n\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/a\u003e¬†\u003c\/h5\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003cdiv\u003e\n\u003ch4\u003eProduct Information\u003c\/h4\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat is the default IP of the device?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe default IP is : 192.168.1.123.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat Niagara version is needed to connect to this controller?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eAt the moment the¬†default Niagara version is N4.4 (4.4.73.24).\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat should I do if I need to use Niagara 4.4.92.2?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eTo install dist you can either copy the \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/Precious%20Versions\/iSMA-MAC36_nre_4.4.92.2\/\"\u003eDIST FILES\u003c\/a\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/iSMA-MAC36_nre_4.4.92.2\/\"\u003e \u003c\/a\u003eto your¬†\u003cbr\u003e%HOMEPATH%\\Niagara4.4\\sw\\inbox folder and use commisioning wizard, or use Platform‚ÜíDistribution File Installer, choose file and install.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat should I do if I need to use Niagara 4.6, 4.7 or 4.8?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e¬†Please download the¬†latest update files¬†\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eHERE\u003c\/span\u003e\u003c\/a\u003e, into the zipfile, which contains the DIST files for version 4.6, 4.7 and 4.8. You will find a file named ‚ÄúiSMA_MAC36_files_installer_v1.0.1152.bat‚Äù, this will copy for you all the DIST files into the relevant folders. After this procedure you will need to restart the Workplace and commission your MAC36NL with the 4.6, 4.7 or 4.8 version.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf you need to upgrade to 4.8\u003c\/span\u003e\u003cspan\u003e¬†and¬†\u003c\/span\u003e\u003cspan\u003ethe controller is already running on¬†lower versions (4.4, 4.6¬†or 4.7) the first step you will need\u003c\/span\u003e\u003cspan\u003e¬†to do is¬†\u003c\/span\u003e\u003cspan\u003eto clean the controller¬†by installing the CleanDist file using the Distribution¬†\u003c\/span\u003e\u003cspan\u003eF\u003c\/span\u003e\u003cspan\u003eile¬†\u003c\/span\u003e\u003cspan\u003eI\u003c\/span\u003e\u003cspan\u003enstaller from the controller's platform and after that commission the MAC36NL controller with the 4.8.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat¬†are the¬†improvements for the MAC36NL¬†with¬†Niagara 4.6 and 4.7?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eWith the release of N4.6 and N4.7 for the MAC36NL you some new features:\u003c\/span\u003e\u003c\/p\u003e\n¬†- BACnet MSTP¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† -¬†HDMI\u003cbr\u003e¬†-¬†Data Recovery Service¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬†-¬†¬†\u003cspan\u003eWeb Service Port Fix\u003c\/span\u003e\u003cbr\u003ePlease see read the \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Release_Note\/iSMA-B-MAC36NL_Release_Notes.pdf\"\u003eRelease Notes\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\n\u003cspan style=\"color: #ff0000;\"\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row row-1\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat are the default platform Credentials?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe default credentials are the same as to the Tridium controllers:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003eUser: tridium\u003c\/p\u003e\n\u003cp\u003ePassword:niagara\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat communication networks are available?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eIn this stage the Networks that work are:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e- Modbus RS485\u003c\/p\u003e\n\u003cp\u003e- Modbus TCP\u003c\/p\u003e\n\u003cp\u003e- BACnet TCP\u003c\/p\u003e\n\u003cp\u003e- BACnet MSTP available for version N4.6 and N4.7.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e-¬†Mbus TCP\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e- Niagara Network\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat features are implemented into this controller compared to the Tridium Jace?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe iSMA has the same features as a Tridium N4 controller:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e-Alarm\u003c\/p\u003e\n\u003cp\u003e-Histories\u003c\/p\u003e\n\u003cp\u003e-PX pages (web User Interface pages) HTML 5 web viewing\u003c\/p\u003e\n\u003cp\u003e-Communication with Niagara controllers and Supervisors through Niagara Network\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhen commissioning I see this message: there is no Core software found that can be installed, what should I do?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe core software is installed from the factoryfor version 4.4.73, you just need to press Next.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eAfter using the commissioning wizard to install the Station and modules, I can see into the Application Directory that there are errors regarding the Web Server and I cannot access the controller from the webpage. How do I resolve that error and access the controller through the web page?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eAt this stage the Web server works with the TCP port above 1024, so you will need to go and change the HTTP and HTTPs ports to be above 1024 (ex: HTTP port - 8080, HTTPs port 8443).\u003cspan\u003e¬†After setting this up please restart the station. \u003cstrong\u003eThis issue was resolved in N4.6 and N4.7 release.\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow does the Local IOs work?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe Local IO driver it is still at an early stage and you will need to Download the¬†\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca style=\"color: #0000ff; text-decoration: underline;\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/iSMAIO.zip\"\u003eJar file.\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e¬†Put it into the Modules folder and restart the Workbench. Go and find the iSMA IO into the Palette.\u003c\/div\u003e\n\u003cdiv class=\"qs-content\"\u003eInto the Drivers add from the iSMA_IO Palette the iSMA IO Network, after that open the Property Sheet of the Drivers to see the recently added Network. Under it add the Local IO Device and under that add the points from the palette.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow do I change the Universal Input type?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eOpen the property sheet of the UI and you will see the Input type property, by default it is set to Voltage.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow do I change the Analog Output type?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eOpen the property sheet of the AO and you will see the Output type property, by default it is set to Voltage.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow can I use the HDMI function?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003e\n\u003cdiv class=\"qs-content\"\u003eAfter you have commissioned the controller on your N4.6 or N4.7¬† and install the iSMA_HDMI jar file, copy the HDMI service from the iSMA_HDMI pallette to the Service folder and you will need to go to the WEB service and activate the HTTP port and disable HTTPS Only. After you make those settings please reboot the controller.¬†\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\" target=\"_blank\" title=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-M-300\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" alt=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-M-300‚Äù style=\"\u003e\u003c\/a\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\" title=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-M-300\"\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"gtx-trans\" style=\"position: absolute; left: 144px; top: 592.562px;\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321574514843,"sku":"iSMA-B-MAC36NL-M;iSMA-B-SD-NL","price":2528.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-B-MAC36NL-M-600x600_ab18aea3-573b-4309-8e64-d1a5947c323f.png?v=1737467222"},{"product_id":"isma-b-mac36nl-m-250","title":"iSMA-B-MAC36NL-M-250","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eThe iSMA-B-MAC36NL is Niagara controller with 36 onboard IO and license of 250 points,¬†one RS485 port and one Mbus port. If more points are needed then you can upgrade in 50 points increment.\u003c\/p\u003e\n\u003cp\u003eThe MAC (Master Application Controller) with built-in different types of I\/O and operating in the Niagara Framework environment. Using the specific local I\/O set 16x UI, 8x AO, 4xDI and 8x DO allow to use the device in different applications. The controller provides control, data logging, alarming, scheduling, integration and visualisation.\u003c\/p\u003e\n\u003cp\u003eTo allow IP connectivity there are 2x Fast Ethernet ports which can operate as two independent ports. Built-in 1x RS485 can be used to expand number of I\/O by connecting MINI or MIX series I\/O modules or to integrate with other subsystems.\u003cbr\u003eiSMA-B-MAC36NL provides rich graphical interface displaying on a standard Web browser or on external display connected to built-in HDMI and USB port (touch-screen support).\u003cbr\u003e\u003cspan\u003eThere are two more hardware versions of the controller available: standard\u003c\/span\u003e\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003eiSMA-B-MAC36NL\u003c\/strong\u003e\u003cspan\u003e¬†and with the¬†\u003c\/span\u003e\u003cstrong\u003esecond RS485\u003c\/strong\u003e\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003eport\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003eT\u003c\/p\u003e\n\u003cp\u003eThe Niagara versions available for this controller in the latest \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\/Niagara\/\"\u003eInstaller\u003c\/a\u003e version:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNiagara 4.4.73 (not recommended)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.4.92 (not recommended)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.6.96.28 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.7.109.20 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.8.0.110 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.9.0.198 (Use the installer v1.4)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.9.1.30 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.0.154 (Use the installer v1.5)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.1.36 (Use the installer v1.7)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.3.20  (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.11.1.16 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.12.0.156 (Use the installer v1.8)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.12.2.16 (Use the installer v1.9)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.7.42.1\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.9.14.1\u003c\/li\u003e\n\u003cli\u003eNiagara 4.13.2.18\u003c\/li\u003e\n\u003cli\u003eNiagara 4.14.0.162\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBACnet MSTP, Data Recovery Service, Web Service Ports fix and HDMI function are now available for N4.6 and higher.\u003c\/li\u003e\n\u003cli\u003eThe Mbus interface will work only if commissioned with Niagara 4.8 or above.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eFor all new features and improvements, please see the \u003c\/span\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\/Release_Note\"\u003eRelease Notes\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMain features\u003cbr\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-6\" style=\"text-align: justify;\"\u003e\n\u003cstrong\u003e16x Universal Inputs (16UI)\u003c\/strong\u003e\n\u003cp\u003eAll Universal Inputs have 16-bit ADC which support the following types of inputs:\u003cbr\u003eTemperature input supports the following types of sensors:\u003cbr\u003e10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1, Pt1000, Ni1000\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFor sensors Pt1000 and Ni1000 use only 16-bit resolution!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage input 0-10 V DC: input resistance 100 kŒ© accuracy ¬±0,1%, measurement resolution 3 mV @ 12-bit\u003cbr\u003eand 1 mV @ 16-bit\u003c\/li\u003e\n\u003cli\u003eCurrent input 0-20 mA (external resistor¬†200 Œ© required)\u003c\/li\u003e\n\u003cli\u003eResistive input 0-1000 kŒ©: measurement resolution\u003cbr\u003efor 20 kŒ© load: 20 Œ© @ 12-bit and 1 Œ© @ 16-bit\u003c\/li\u003e\n\u003cli\u003eDry contact input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e4x Digital Inputs (4DI)\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eDry contact inputs\u003c\/li\u003e\n\u003cli\u003eFast pulse counter up to 100 Hz saved in SD Card\u003c\/li\u003e\n\u003c\/ul\u003e\n8x Analog Outputs (8AO)\n\u003cp\u003eAll Analog Outputs are equipped with 12-bit ADC provides 10 mV resolution and accuracy less than ¬±0,5%. They support the following output types:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage: 0-10 V DC max. load up to 20 mA\u003c\/li\u003e\n\u003cli\u003ePWM: 0,01 Hz, 0,1 Hz, 1 Hz, 10 Hz, 100 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e8x Digital Outputs (8DO) \u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eRelay output (NO): max. 3 A @ 30 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-6\"\u003e\n\u003cstrong\u003ePlatform\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eMulticore Cortex-A Series ARM Processor\u003c\/li\u003e\n\u003cli\u003e1GB DDR3 SDRAM\u003c\/li\u003e\n\u003cli\u003eRemovable micro-SD card ‚Äì 4 GB\u003cbr\u003e(2 GB system reserved \/ 2 GB user storage)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eCommunication \u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003eRS485 half-duplex, opto-isolated\u003c\/li\u003e\n\u003cli\u003eBaud rate from 2400 to 115200\u003c\/li\u003e\n\u003cli\u003e2x Fast Ethernet (independent)\u003c\/li\u003e\n\u003cli\u003e2x USB (1x OTG, 1x Host)\u003c\/li\u003e\n\u003cli\u003eHDMI type A (standard)\u003c\/li\u003e\n\u003cli\u003eMicro SD card slot\u003c\/li\u003e\n\u003cli\u003eModbus RTU\/ASCII\/IP, BACnet MSTP\/IP, oBIX, SNMP,\u003cbr\u003eLON\/IP, KNX\/IP\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eM-bus interface (on Niagara 4.8)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003ePower supply \u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003e24 V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eHousing\u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003eDimensions: 160x110x62 mm.\u003c\/li\u003e\n\u003cli\u003eConstruction: UL approved,\u003cbr\u003eself-extinguishing plastic (PC\/ABS)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting DIN (DIN EN 50022 norm)\u003c\/li\u003e\n\u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: justify;\"\u003eOperating temperature: -10¬∞C to 50¬∞C\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eStorage temperature: -40¬∞C to 85¬∞C\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eRelative humidity: 5% to 95%, no condensation\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eIngress Protection Rating: IP40 ‚Äì for indoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\n\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/a\u003e¬†\u003c\/h5\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003cdiv\u003e\n\u003ch4\u003eProduct Informations\u003c\/h4\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat is the default IP of the device?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe default IP is : 192.168.1.123.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat Niagara version is needed to connect to this controller?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eAt the moment the¬†default Niagara version is N4.4 (4.4.73.24).\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat should I do if I need to use Niagara 4.4.92.2?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eTo install dist you can either copy the \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/Precious%20Versions\/iSMA-MAC36_nre_4.4.92.2\/\"\u003eDIST FILES\u003c\/a\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/iSMA-MAC36_nre_4.4.92.2\/\"\u003e \u003c\/a\u003eto your¬†\u003cbr\u003e%HOMEPATH%\\Niagara4.4\\sw\\inbox folder and use commisioning wizard, or use Platform‚ÜíDistribution File Installer, choose file and install.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat should I do if I need to use Niagara 4.6, 4.7 or 4.8?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e¬†Please download the¬†latest update files¬†\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eHERE\u003c\/span\u003e\u003c\/a\u003e, into the zipfile, which contains the DIST files for version 4.6, 4.7 and 4.8. You will find a file named ‚ÄúiSMA_MAC36_files_installer_v1.0.1152.bat‚Äù, this will copy for you all the DIST files into the relevant folders. After this procedure you will need to restart the Workplace and commission your MAC36NL with the 4.6, 4.7 or 4.8 version.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf you need to upgrade to 4.8\u003c\/span\u003e\u003cspan\u003e¬†and¬†\u003c\/span\u003e\u003cspan\u003ethe controller is already running on¬†lower versions (4.4, 4.6¬†or 4.7) the first step you will need\u003c\/span\u003e\u003cspan\u003e¬†to do is¬†\u003c\/span\u003e\u003cspan\u003eto clean the controller¬†by installing the CleanDist file using the Distribution¬†\u003c\/span\u003e\u003cspan\u003eF\u003c\/span\u003e\u003cspan\u003eile¬†\u003c\/span\u003e\u003cspan\u003eI\u003c\/span\u003e\u003cspan\u003enstaller from the controller's platform and after that commission the MAC36NL controller with the 4.8.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat¬†are the¬†improvements for the MAC36NL¬†with¬†Niagara 4.6 and 4.7?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eWith the release of N4.6 and N4.7 for the MAC36NL you some new features:\u003c\/span\u003e\u003c\/p\u003e\n¬†- BACnet MSTP¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† -¬†HDMI\u003cbr\u003e¬†-¬†Data Recovery Service¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬†-¬†¬†\u003cspan\u003eWeb Service Port Fix\u003c\/span\u003e\u003cbr\u003ePlease see read the \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Release_Note\/iSMA-B-MAC36NL_Release_Notes.pdf\"\u003eRelease Notes\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\n\u003cspan style=\"color: #ff0000;\"\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row row-1\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat are the default platform Credentials?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe default credentials are the same as to the Tridium controllers:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003eUser: tridium\u003c\/p\u003e\n\u003cp\u003ePassword:niagara\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat communication networks are available?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eIn this stage the Networks that work are:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e- Modbus RS485\u003c\/p\u003e\n\u003cp\u003e- Modbus TCP\u003c\/p\u003e\n\u003cp\u003e- BACnet TCP\u003c\/p\u003e\n\u003cp\u003e- BACnet MSTP available for version N4.6 and N4.7.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e-¬†Mbus TCP\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e- Niagara Network\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat features are implemented into this controller compared to the Tridium Jace?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe iSMA has the same features as a Tridium N4 controller:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e-Alarm\u003c\/p\u003e\n\u003cp\u003e-Histories\u003c\/p\u003e\n\u003cp\u003e-PX pages (web User Interface pages) HTML 5 web viewing\u003c\/p\u003e\n\u003cp\u003e-Communication with Niagara controllers and Supervisors through Niagara Network\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhen commissioning I see this message: there is no Core software found that can be installed, what should I do?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe core software is installed from the factoryfor version 4.4.73, you just need to press Next.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eAfter using the commissioning wizard to install the Station and modules, I can see into the Application Directory that there are errors regarding the Web Server and I cannot access the controller from the webpage. How do I resolve that error and access the controller through the web page?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eAt this stage the Web server works with the TCP port above 1024, so you will need to go and change the HTTP and HTTPs ports to be above 1024 (ex: HTTP port - 8080, HTTPs port 8443).\u003cspan\u003e¬†After setting this up please restart the station. \u003cstrong\u003eThis issue was resolved in N4.6 and N4.7 release.\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow does the Local IOs work?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe Local IO driver it is still at an early stage and you will need to Download the¬†\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/iSMAIO.zip\" style=\"color: #0000ff; text-decoration: underline;\"\u003eJar file.\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e¬†Put it into the Modules folder and restart the Workbench. Go and find the iSMA IO into the Palette.\u003c\/div\u003e\n\u003cdiv class=\"qs-content\"\u003eInto the Drivers add from the iSMA_IO Palette the iSMA IO Network, after that open the Property Sheet of the Drivers to see the recently added Network. Under it add the Local IO Device and under that add the points from the palette.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow do I change the Universal Input type?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eOpen the property sheet of the UI and you will see the Input type property, by default it is set to Voltage.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow do I change the Analog Output type?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eOpen the property sheet of the AO and you will see the Output type property, by default it is set to Voltage.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow can I use the HDMI function?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003e\n\u003cdiv class=\"qs-content\"\u003eAfter you have commissioned the controller on your N4.6 or N4.7¬† and install the iSMA_HDMI jar file, copy the HDMI service from the iSMA_HDMI pallette to the Service folder and you will need to go to the WEB service and activate the HTTP port and disable HTTPS Only. After you make those settings please reboot the controller.¬†\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e¬†Do you have a question about this product?\u003c\/strong\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\" target=\"_blank\" title=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-M-250\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" alt=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-M-250‚Äù style=\"\u003e\u003c\/a\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\" title=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-M-250\"\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"gtx-trans\" style=\"position: absolute; left: 146px; top: 572.969px;\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321576972443,"sku":"iSMA-B-MAC36NL-M;iSMA-B-SD-NL","price":2291.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-B-MAC36NL-M-600x600_bc25411c-cb80-4d5e-852b-bd864d80aa79.png?v=1737467221"},{"product_id":"isma-b-mac36nl-m-150","title":"iSMA-B-MAC36NL-M-150","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eThe iSMA-B-MAC36NL is Niagara controller with 36 onboard IO and license of 150 points and¬†one RS485 port. If more points are needed then you can upgrade in 50 points increment.\u003c\/p\u003e\n\u003cp\u003eThe MAC (Master Application Controller) with built-in different types of I\/O and operating in the Niagara Framework environment. Using the specific local I\/O set 16x UI, 8x AO, 4xDI and 8x DO allow to use the device in different applications. The controller provides control, data logging, alarming, scheduling, integration and visualisation.\u003c\/p\u003e\n\u003cp\u003eTo allow IP connectivity there are 2x Fast Ethernet ports which can operate as two independent ports. Built-in 1x RS485 can be used to expand number of I\/O by connecting MINI or MIX series I\/O modules or to integrate with other subsystems.\u003cbr\u003eiSMA-B-MAC36NL provides rich graphical interface displaying on a standard Web browser or on external display connected to built-in HDMI and USB port (touch-screen support).\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eThere are two more hardware versions of the controller with the¬†\u003c\/span\u003e\u003cstrong\u003esecond RS485\u003c\/strong\u003e\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003eport\u003c\/strong\u003e\u003cspan\u003e¬†and¬†\u003c\/span\u003e\u003cstrong\u003eM-Bus interface\u003c\/strong\u003e\u003cspan\u003e¬†available.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003eThe Niagara versions available for this controller in the latest \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\/Niagara\/\"\u003eInstaller\u003c\/a\u003e version:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNiagara 4.4.73 (not recommended)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.4.92 (not recommended)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.6.96.28 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.7.109.20 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.8.0.110 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.9.0.198 (Use the installer v1.4)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.9.1.30 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.0.154 (Use the installer v1.5)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.1.36 (Use the installer v1.7)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.3.20  (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.11.1.16 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.12.0.156 (Use the installer v1.8)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.12.2.16 (Use the installer v1.9)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.7.42.1\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.9.14.1\u003c\/li\u003e\n\u003cli\u003eNiagara 4.13.2.18\u003c\/li\u003e\n\u003cli\u003eNiagara 4.14.0.162\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBACnet MSTP, Data Recovery Service, Web Service Ports fix and HDMI function are now available for N4.6 and higher.\u003c\/li\u003e\n\u003cli\u003eThe Mbus interface will work only if commissioned with Niagara 4.8 or above.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eFor all new features and improvements, please see the \u003c\/span\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\/Release_Note\"\u003eRelease Notes\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMain features\u003cbr\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv style=\"text-align: justify;\" class=\"col-sm-6\"\u003e\n\u003cstrong\u003e16x Universal Inputs (16UI)\u003c\/strong\u003e\n\u003cp\u003eAll Universal Inputs have 16-bit ADC which support the following types of inputs:\u003cbr\u003eTemperature input supports the following types of sensors:\u003cbr\u003e10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1, Pt1000, Ni1000\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFor sensors Pt1000 and Ni1000 use only 16-bit resolution!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage input 0-10 V DC: input resistance 100 kŒ© accuracy ¬±0,1%, measurement resolution 3 mV @ 12-bit\u003cbr\u003eand 1 mV @ 16-bit\u003c\/li\u003e\n\u003cli\u003eCurrent input 0-20 mA (external resistor¬†200 Œ© required)\u003c\/li\u003e\n\u003cli\u003eResistive input 0-1000 kŒ©: measurement resolution\u003cbr\u003efor 20 kŒ© load: 20 Œ© @ 12-bit and 1 Œ© @ 16-bit\u003c\/li\u003e\n\u003cli\u003eDry contact input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e4x Digital Inputs (4DI)\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eDry contact inputs\u003c\/li\u003e\n\u003cli\u003eFast pulse counter up to 100 Hz saved in SD Card\u003c\/li\u003e\n\u003c\/ul\u003e\n8x Analog Outputs (8AO)\n\u003cp\u003eAll Analog Outputs are equipped with 12-bit ADC provides 10 mV resolution and accuracy less than ¬±0,5%. They support the following output types:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage: 0-10 V DC max. load up to 20 mA\u003c\/li\u003e\n\u003cli\u003ePWM: 0,01 Hz, 0,1 Hz, 1 Hz, 10 Hz, 100 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e8x Digital Outputs (8DO) \u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eRelay output (NO): max. 3 A @ 30 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-6\"\u003e\n\u003cstrong\u003ePlatform\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eMulticore Cortex-A Series ARM Processor\u003c\/li\u003e\n\u003cli\u003e1GB DDR3 SDRAM\u003c\/li\u003e\n\u003cli\u003eRemovable micro-SD card ‚Äì 4 GB\u003cbr\u003e(2 GB system reserved \/ 2 GB user storage)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eCommunication \u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003eRS485 half-duplex, opto-isolated\u003c\/li\u003e\n\u003cli\u003eBaud rate from 2400 to 115200\u003c\/li\u003e\n\u003cli\u003e2x Fast Ethernet (independent)\u003c\/li\u003e\n\u003cli\u003e2x USB (1x OTG, 1x Host)\u003c\/li\u003e\n\u003cli\u003eHDMI type A (standard)\u003c\/li\u003e\n\u003cli\u003eMicro SD card slot\u003c\/li\u003e\n\u003cli\u003eModbus RTU\/ASCII\/IP, BACnet MSTP\/IP, oBIX, SNMP,\u003cbr\u003eLON\/IP, KNX\/IP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003ePower supply \u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003e24 V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eHousing\u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003eDimensions: 160x110x62 mm.\u003c\/li\u003e\n\u003cli\u003eConstruction: UL approved,\u003cbr\u003eself-extinguishing plastic (PC\/ABS)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting DIN (DIN EN 50022 norm)\u003c\/li\u003e\n\u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: justify;\"\u003eOperating temperature: -10¬∞C to 50¬∞C\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eStorage temperature: -40¬∞C to 85¬∞C\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eRelative humidity: 5% to 95%, no condensation\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eIngress Protection Rating: IP40 ‚Äì for indoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\n\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/a\u003eProduct Informations\u003c\/h5\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003cdiv\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat is the default IP of the device?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe default IP is : 192.168.1.123.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat Niagara version is needed to connect to this controller?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eAt the moment the¬†default Niagara version is N4.4 (4.4.73.24).\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat should I do if I need to use Niagara 4.4.92.2?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eTo install dist you can either copy the \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/Precious%20Versions\/iSMA-MAC36_nre_4.4.92.2\/\"\u003eDIST FILES\u003c\/a\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/iSMA-MAC36_nre_4.4.92.2\/\"\u003e \u003c\/a\u003eto your¬†\u003cbr\u003e%HOMEPATH%\\Niagara4.4\\sw\\inbox folder and use commisioning wizard, or use Platform‚ÜíDistribution File Installer, choose file and install.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat should I do if I need to use Niagara 4.6, 4.7 or 4.8?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e¬†Please download the¬†latest update files¬†\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eHERE\u003c\/span\u003e\u003c\/a\u003e, into the zipfile, which contains the DIST files for version 4.6, 4.7 and 4.8. You will find a file named ‚ÄúiSMA_MAC36_files_installer_v1.0.1152.bat‚Äù, this will copy for you all the DIST files into the relevant folders. After this procedure you will need to restart the Workplace and commission your MAC36NL with the 4.6, 4.7 or 4.8 version.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf you need to upgrade to 4.8\u003c\/span\u003e\u003cspan\u003e¬†and¬†\u003c\/span\u003e\u003cspan\u003ethe controller is already running on¬†lower versions (4.4, 4.6¬†or 4.7) the first step you will need\u003c\/span\u003e\u003cspan\u003e¬†to do is¬†\u003c\/span\u003e\u003cspan\u003eto clean the controller¬†by installing the CleanDist file using the Distribution¬†\u003c\/span\u003e\u003cspan\u003eF\u003c\/span\u003e\u003cspan\u003eile¬†\u003c\/span\u003e\u003cspan\u003eI\u003c\/span\u003e\u003cspan\u003enstaller from the controller's platform and after that commission the MAC36NL controller with the 4.8.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat¬†are the¬†improvements for the MAC36NL¬†with¬†Niagara 4.6 and 4.7?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eWith the release of N4.6 and N4.7 for the MAC36NL you some new features:\u003c\/span\u003e\u003c\/p\u003e\n¬†- BACnet MSTP¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† -¬†HDMI\u003cbr\u003e¬†-¬†Data Recovery Service¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬†-¬†¬†\u003cspan\u003eWeb Service Port Fix\u003c\/span\u003e\u003cbr\u003ePlease see read the \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Release_Note\/iSMA-B-MAC36NL_Release_Notes.pdf\"\u003eRelease Notes\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\n\u003cspan style=\"color: #ff0000;\"\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row row-1\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat are the default platform Credentials?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe default credentials are the same as to the Tridium controllers:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003eUser: tridium\u003c\/p\u003e\n\u003cp\u003ePassword:niagara\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat communication networks are available?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eIn this stage the Networks that work are:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e- Modbus RS485\u003c\/p\u003e\n\u003cp\u003e- Modbus TCP\u003c\/p\u003e\n\u003cp\u003e- BACnet TCP\u003c\/p\u003e\n\u003cp\u003e- BACnet MSTP available for version N4.6 and N4.7.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e-¬†Mbus TCP\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e- Niagara Network\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat features are implemented into this controller compared to the Tridium Jace?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe iSMA has the same features as a Tridium N4 controller:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e-Alarm\u003c\/p\u003e\n\u003cp\u003e-Histories\u003c\/p\u003e\n\u003cp\u003e-PX pages (web User Interface pages) HTML 5 web viewing\u003c\/p\u003e\n\u003cp\u003e-Communication with Niagara controllers and Supervisors through Niagara Network\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhen commissioning I see this message: there is no Core software found that can be installed, what should I do?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe core software is installed from the factoryfor version 4.4.73, you just need to press Next.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eAfter using the commissioning wizard to install the Station and modules, I can see into the Application Directory that there are errors regarding the Web Server and I cannot access the controller from the webpage. How do I resolve that error and access the controller through the web page?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eAt this stage the Web server works with the TCP port above 1024, so you will need to go and change the HTTP and HTTPs ports to be above 1024 (ex: HTTP port - 8080, HTTPs port 8443).\u003cspan\u003e¬†After setting this up please restart the station. \u003cstrong\u003eThis issue was resolved in N4.6 and N4.7 release.\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow does the Local IOs work?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe Local IO driver it is still at an early stage and you will need to Download the¬†\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca style=\"color: #0000ff; text-decoration: underline;\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/iSMAIO.zip\"\u003eJar file.\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e¬†Put it into the Modules folder and restart the Workbench. Go and find the iSMA IO into the Palette.\u003c\/div\u003e\n\u003cdiv class=\"qs-content\"\u003eInto the Drivers add from the iSMA_IO Palette the iSMA IO Network, after that open the Property Sheet of the Drivers to see the recently added Network. Under it add the Local IO Device and under that add the points from the palette.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow do I change the Universal Input type?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eOpen the property sheet of the UI and you will see the Input type property, by default it is set to Voltage.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow do I change the Analog Output type?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eOpen the property sheet of the AO and you will see the Output type property, by default it is set to Voltage.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow can I use the HDMI function?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003e\n\u003cdiv class=\"qs-content\"\u003eAfter you have commissioned the controller on your N4.6 or N4.7¬† and install the iSMA_HDMI jar file, copy the HDMI service from the iSMA_HDMI pallette to the Service folder and you will need to go to the WEB service and activate the HTTP port and disable HTTPS Only. After you make those settings please reboot the controller.¬†\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e¬†Do you have a question about this product?\u003cbr\u003e\u003cbr\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\" target=\"_blank\" title=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-150\" rel=\"noopener\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-150‚Äù style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-150\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\"\u003e \u003c\/a\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321578152091,"sku":"iSMA-B-MAC36NL-M;iSMA-B-SD-NL","price":2154.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-B-MAC36NL-M-600x600_79897e8d-c3a8-44cb-96ee-0bf92bc513d6.png?v=1737467221"},{"product_id":"isma-b-mac36nl-m-100","title":"iSMA-B-MAC36NL-M-100","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eThe iSMA-B-MAC36NL is Niagara controller with 36 onboard IO and license of 100 points,¬†one RS485 port and one Mbus port. If more points are needed then you can upgrade in 50 points increment.\u003c\/p\u003e\n\u003cp\u003eThe MAC (Master Application Controller) with built-in different types of I\/O and operating in the Niagara Framework environment. Using the specific local I\/O set 16x UI, 8x AO, 4xDI and 8x DO allow to use the device in different applications. The controller provides control, data logging, alarming, scheduling, integration and visualisation.\u003c\/p\u003e\n\u003cp\u003eTo allow IP connectivity there are 2x Fast Ethernet ports which can operate as two independent ports. Built-in 1x RS485 can be used to expand number of I\/O by connecting MINI or MIX series I\/O modules or to integrate with other subsystems.\u003cbr\u003eiSMA-B-MAC36NL provides rich graphical interface displaying on a standard Web browser or on external display connected to built-in HDMI and USB port (touch-screen support).\u003cbr\u003e\u003cspan\u003eThere are two more hardware versions of the controller available: standard\u003c\/span\u003e\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003eiSMA-B-MAC36NL\u003c\/strong\u003e\u003cspan\u003e¬†and with the¬†\u003c\/span\u003e\u003cstrong\u003esecond RS485\u003c\/strong\u003e\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003eport\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003eThe Niagara versions available for this controller in the latest \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\/Niagara\/\"\u003eInstaller\u003c\/a\u003e version:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNiagara 4.4.73 (not recommended)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.4.92 (not recommended)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.6.96.28 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.7.109.20 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.8.0.110 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.9.0.198 (Use the installer v1.4)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.9.1.30 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.0.154 (Use the installer v1.5)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.1.36 (Use the installer v1.7)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.3.20  (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.11.1.16 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.12.0.156 (Use the installer v1.8)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.12.2.16 (Use the installer v1.9)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.7.42.1\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.9.14.1\u003c\/li\u003e\n\u003cli\u003eNiagara 4.13.2.18\u003c\/li\u003e\n\u003cli\u003eNiagara 4.14.0.162\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBACnet MSTP, Data Recovery Service, Web Service Ports fix and HDMI function are now available for N4.6 and higher.\u003c\/li\u003e\n\u003cli\u003eThe Mbus interface will work only if commissioned with Niagara 4.8 or above.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eFor all new features and improvements, please see the \u003c\/span\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\/Release_Note\"\u003eRelease Notes\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMain features\u003cbr\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv style=\"text-align: justify;\" class=\"col-sm-6\"\u003e\n\u003cstrong\u003e16x Universal Inputs (16UI)\u003c\/strong\u003e\n\u003cp\u003eAll Universal Inputs have 16-bit ADC which support the following types of inputs:\u003cbr\u003eTemperature input supports the following types of sensors:\u003cbr\u003e10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1, Pt1000, Ni1000\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFor sensors Pt1000 and Ni1000 use only 16-bit resolution!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage input 0-10 V DC: input resistance 100 kŒ© accuracy ¬±0,1%, measurement resolution 3 mV @ 12-bit\u003cbr\u003eand 1 mV @ 16-bit\u003c\/li\u003e\n\u003cli\u003eCurrent input 0-20 mA (external resistor¬†200 Œ© required)\u003c\/li\u003e\n\u003cli\u003eResistive input 0-1000 kŒ©: measurement resolution\u003cbr\u003efor 20 kŒ© load: 20 Œ© @ 12-bit and 1 Œ© @ 16-bit\u003c\/li\u003e\n\u003cli\u003eDry contact input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e4x Digital Inputs (4DI)\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eDry contact inputs\u003c\/li\u003e\n\u003cli\u003eFast pulse counter up to 100 Hz saved in SD Card\u003c\/li\u003e\n\u003c\/ul\u003e\n8x Analog Outputs (8AO)\n\u003cp\u003eAll Analog Outputs are equipped with 12-bit ADC provides 10 mV resolution and accuracy less than ¬±0,5%. They support the following output types:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage: 0-10 V DC max. load up to 20 mA\u003c\/li\u003e\n\u003cli\u003ePWM: 0,01 Hz, 0,1 Hz, 1 Hz, 10 Hz, 100 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e8x Digital Outputs (8DO) \u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eRelay output (NO): max. 3 A @ 30 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-6\"\u003e\n\u003cstrong\u003ePlatform\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eMulticore Cortex-A Series ARM Processor\u003c\/li\u003e\n\u003cli\u003e1GB DDR3 SDRAM\u003c\/li\u003e\n\u003cli\u003eRemovable micro-SD card ‚Äì 4 GB\u003cbr\u003e(2 GB system reserved \/ 2 GB user storage)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eCommunication \u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003eRS485 half-duplex, opto-isolated\u003c\/li\u003e\n\u003cli\u003eBaud rate from 2400 to 115200\u003c\/li\u003e\n\u003cli\u003e2x Fast Ethernet (independent)\u003c\/li\u003e\n\u003cli\u003e2x USB (1x OTG, 1x Host)\u003c\/li\u003e\n\u003cli\u003eHDMI type A (standard)\u003c\/li\u003e\n\u003cli\u003eMicro SD card slot\u003c\/li\u003e\n\u003cli\u003eModbus RTU\/ASCII\/IP, BACnet MSTP\/IP, oBIX, SNMP,\u003cbr\u003eLON\/IP, KNX\/IP\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eM-bus interface (on Niagara 4.8)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003ePower supply \u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003e24 V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eHousing\u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003eDimensions: 160x110x62 mm.\u003c\/li\u003e\n\u003cli\u003eConstruction: UL approved,\u003cbr\u003eself-extinguishing plastic (PC\/ABS)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting DIN (DIN EN 50022 norm)\u003c\/li\u003e\n\u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: justify;\"\u003eOperating temperature: -10¬∞C to 50¬∞C\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eStorage temperature: -40¬∞C to 85¬∞C\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eRelative humidity: 5% to 95%, no condensation\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eIngress Protection Rating: IP40 ‚Äì for indoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch5\u003eFAQ\u003c\/h5\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003ch4\u003eProduct Informations\u003c\/h4\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat is the default IP of the device?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe default IP is : 192.168.1.123.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat Niagara version is needed to connect to this controller?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eAt the moment the¬†default Niagara version is N4.4 (4.4.73.24).\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat should I do if I need to use Niagara 4.4.92.2?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eTo install dist you can either copy the \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/Precious%20Versions\/iSMA-MAC36_nre_4.4.92.2\/\"\u003eDIST FILES\u003c\/a\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/iSMA-MAC36_nre_4.4.92.2\/\"\u003e \u003c\/a\u003eto your¬†\u003cbr\u003e%HOMEPATH%\\Niagara4.4\\sw\\inbox folder and use commisioning wizard, or use Platform‚ÜíDistribution File Installer, choose file and install.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat should I do if I need to use Niagara 4.6, 4.7 or 4.8?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e¬†Please download the¬†latest update files¬†\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eHERE\u003c\/span\u003e\u003c\/a\u003e, into the zipfile, which contains the DIST files for version 4.6, 4.7 and 4.8. You will find a file named ‚ÄúiSMA_MAC36_files_installer_v1.0.1152.bat‚Äù, this will copy for you all the DIST files into the relevant folders. After this procedure you will need to restart the Workplace and commission your MAC36NL with the 4.6, 4.7 or 4.8 version.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf you need to upgrade to 4.8¬†and the controller is already running on¬†lower versions (4.4, 4.6¬†or 4.7) the first step you will need¬†to do is to clean the controller¬†by installing the CleanDist file using the Distribution File Installer from the controller's platform and after that commission the MAC36NL controller with the 4.8.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat¬†are the¬†improvements for the MAC36NL¬†with¬†Niagara 4.6 and 4.7?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eWith the release of N4.6 and N4.7 for the MAC36NL you some new features:\u003c\/span\u003e\u003c\/p\u003e\n¬†- BACnet MSTP¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† -¬†HDMI\u003cbr\u003e¬†-¬†Data Recovery Service¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬†-¬†¬†\u003cspan\u003eWeb Service Port Fix\u003c\/span\u003e\u003cbr\u003ePlease see read the \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Release_Note\/iSMA-B-MAC36NL_Release_Notes.pdf\"\u003eRelease Notes\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\n\u003cspan style=\"color: #ff0000;\"\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row row-1\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat are the default platform Credentials?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe default credentials are the same as to the Tridium controllers:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003eUser: tridium\u003c\/p\u003e\n\u003cp\u003ePassword:niagara\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat communication networks are available?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eIn this stage the Networks that work are:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e- Modbus RS485\u003c\/p\u003e\n\u003cp\u003e- Modbus TCP\u003c\/p\u003e\n\u003cp\u003e- BACnet TCP\u003c\/p\u003e\n\u003cp\u003e- BACnet MSTP available for version N4.6 and N4.7.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e-¬†Mbus TCP\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e- Niagara Network\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat features are implemented into this controller compared to the Tridium Jace?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe iSMA has the same features as a Tridium N4 controller:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e-Alarm\u003c\/p\u003e\n\u003cp\u003e-Histories\u003c\/p\u003e\n\u003cp\u003e-PX pages (web User Interface pages) HTML 5 web viewing\u003c\/p\u003e\n\u003cp\u003e-Communication with Niagara controllers and Supervisors through Niagara Network\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhen commissioning I see this message: there is no Core software found that can be installed, what should I do?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe core software is installed from the factoryfor version 4.4.73, you just need to press Next.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eAfter using the commissioning wizard to install the Station and modules, I can see into the Application Directory that there are errors regarding the Web Server and I cannot access the controller from the webpage. How do I resolve that error and access the controller through the web page?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eAt this stage the Web server works with the TCP port above 1024, so you will need to go and change the HTTP and HTTPs ports to be above 1024 (ex: HTTP port - 8080, HTTPs port 8443).\u003cspan\u003e¬†After setting this up please restart the station. \u003cstrong\u003eThis issue was resolved in N4.6 and N4.7 release.\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow does the Local IOs work?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe Local IO driver it is still at an early stage and you will need to Download the¬†\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca style=\"color: #0000ff; text-decoration: underline;\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/iSMAIO.zip\"\u003eJar file.\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e¬†Put it into the Modules folder and restart the Workbench. Go and find the iSMA IO into the Palette.\u003c\/div\u003e\n\u003cdiv class=\"qs-content\"\u003eInto the Drivers add from the iSMA_IO Palette the iSMA IO Network, after that open the Property Sheet of the Drivers to see the recently added Network. Under it add the Local IO Device and under that add the points from the palette.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow do I change the Universal Input type?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eOpen the property sheet of the UI and you will see the Input type property, by default it is set to Voltage.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow do I change the Analog Output type?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eOpen the property sheet of the AO and you will see the Output type property, by default it is set to Voltage.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow can I use the HDMI function?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003e\n\u003cdiv class=\"qs-content\"\u003eAfter you have commissioned the controller on your N4.6 or N4.7¬† and install the iSMA_HDMI jar file, copy the HDMI service from the iSMA_HDMI pallette to the Service folder and you will need to go to the WEB service and activate the HTTP port and disable HTTPS Only. After you make those settings please reboot the controller.¬†\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"faq-section\"\u003e\n\u003cdiv class=\"question-v1\"\u003e\n\u003ch4\u003eShipping Informations\u003c\/h4\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat Shipping Methods are Available?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eWe do UK next day delivery and 2 working days for Ireland We do Europe standard 3 day delivery. We do Worldwide delivery between 2 and 7 days depending on each country.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow Can I Return A Faulty Product?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eReturns are free of charge we will organize the pickup only in the case the product is faulty. Please contact support@innon.co.uk to obtain an RMA number first.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow Do I Track My Order?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eOnce we ship your order, you will receive a tracking number and you will also find it in My Account section.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow can I place an Order?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003e\n\u003cp\u003eYou can place an order online and pay by credit\/debit card if you do not have a Trading Account.\u003cbr\u003eYou can please your order online and pay by Trading Account if you have a Business Trading Account.\u003cbr\u003eTo open a Business Trading Account \u003ca title=\"Open a trading account\" href=\"https:\/\/innon.myshopify.com\/admin\/products\/pages\/open-an-account-with-innon-energy\" target=\"_blank\"\u003eplease fill in this form and send it back to \u003c\/a\u003eoffice@innon.co.uk\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\" title=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-RS-250\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" alt=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-RS-250‚Äù style=\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003cdiv style=\"position: absolute; left: 146px; top: 572.969px;\" id=\"gtx-trans\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321579102363,"sku":"iSMA-B-MAC36NL-M;iSMA-B-SD-NL","price":1918.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-B-MAC36NL-M-600x600.png?v=1737467220"},{"product_id":"isma-d-pd-rj45-usb","title":"ISMA-D-PD-RJ45-USB","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eUSB head -- RJ45 head, L=1500mm , UL2725 24\/1P+28#, 3.8 mm Cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321580380315,"sku":"ISMA-D-PD-RJ45-USB","price":11.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-D-PD-RJ45-USB-web.png?v=1737467218"},{"product_id":"isma-d-pa-usb","title":"ISMA-D-PA-USB","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eUSB 2.0 to USB A Cable for iSMA-D-PA10C-B1 and iSMA-D-PA15C-B1.\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e\u003c\/p\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321580544155,"sku":"ISMA-D-PA-USB","price":9.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-D-PA-USB.png?v=1737467217"},{"product_id":"sma-0100-5yr","title":"SMA-0100-5YR","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eiSMA MAC36NL (5,000 to 9,999) Proxy Points -¬†5 year maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321611083931,"sku":"SMA-0100-5YR","price":3441.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/iSMAMAC36NLSoftwareMaintenance_fe47654b-6aa2-4544-964a-8ef94317c184.png?v=1737467209"},{"product_id":"sma-0100-3yr","title":"SMA-0100-3YR","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eiSMA MAC36NL (5,000 to 9,999) Proxy Points -¬†3 year maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321611280539,"sku":"SMA-0100-3YR","price":2685.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/iSMAMAC36NLSoftwareMaintenance_e3082635-3bbf-4573-bae2-1c9bee561a68.png?v=1737467209"},{"product_id":"sma-0100-1yr","title":"SMA-0100-1YR","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eiSMA MAC36NL (5,000 to 9,999) Proxy Points - 1 year maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e\u003c\/p\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321611411611,"sku":"SMA-0100-1YR","price":1099.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/iSMAMAC36NLSoftwareMaintenance_82c04bcb-3d8c-4280-bc1b-a46e56b4c016.png?v=1737467208"},{"product_id":"isma-d-pa15c-b1-uk","title":"iSMA-D-PA15C-B1-UK","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eiSMA-D-PA15C-B1-UK is 15'' Industrial PC Panel with Android 7.1 operating system and UK power adaptor.\u003c\/p\u003e\n\u003cp\u003eIf you are looking for a fast, robust and sharp industrial display then this is it.¬†Set it up in minutes with the¬†help¬†of dedicated apps:\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eAutologin function for any Niagara 4 system: MAC36NL, JACE8000, N4 Supervisor.¬†\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSetup Wizard¬†\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e Kiosk mode.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYou can connect it to iSMA-B-MAC36NL, JACE or other supervisor powered by Niagara 4 to display graphics by the web page from the Niagara system.\u003cbr\u003eAs a Panel PC with Android, it can be also used as User\u003cbr\u003eInterface. You can install a dedicated application that will\u003cbr\u003eallow communication with other devices in BMS\u003cbr\u003ethe system, for example, our Android application designed for connectivity with Niagara station. The Aspect Ratio 16:9 with resolution 1366x768 allows\u003cbr\u003efor displaying graphics clearly. The panel can be built into the wall, it is compatible with VESA. The panel has an extensive menu in 7 languages, in which we can customize the displayed image.\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ch3\u003eDisplay\u003c\/h3\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cul\u003e\n\u003cli\u003eSize 10,1‚Äô‚Äô\u003c\/li\u003e\n\u003cli\u003eAspect Ratio 16:9\u003c\/li\u003e\n\u003cli\u003eResolution 1366x768\u003c\/li\u003e\n\u003cli\u003eContrast 800:1\u003c\/li\u003e\n\u003cli\u003eLuminance 300 nit, up to 800 nit\u003c\/li\u003e\n\u003cli\u003eResponse time 5 ms\u003c\/li\u003e\n\u003cli\u003eActive Area (mm) 222.7x125.2\u003c\/li\u003e\n\u003cli\u003eDisplay colours 16,7 M (8-bit)\u003c\/li\u003e\n\u003cli\u003eView angle 75\/75\/75\/75\u003c\/li\u003e\n\u003cli\u003e10-point capacitive touch screen\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \n\n\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-D-PA\/\" target=\"_blank\" title=\"Documentation \u0026amp; Downloads for iSMA-D-PA15C-B1-UK\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-D-PA15C-B1-UKstyle=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-D-PA15C-B1-UK\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-D-PA\/\"\u003e \u003c\/a\u003e\n\n ","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321646145691,"sku":"iSMA-D-PA15C-B1-UK","price":1596.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/files\/isma-d-pa10-1.png?v=1737467256"},{"product_id":"isma-d-pa10c-b1-uk","title":"iSMA-D-PA10C-B1-UK","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eiSMA-D-PA10C-B1-UK is 10'' Industrial PC Panel with Android 7.1 operating system and UK power adaptor.\u003c\/p\u003e\n\u003cp\u003eIf you are looking for a fast, robust and sharp industrial display then this is it.¬†Set it up in minutes with the¬†help¬†of dedicated apps:\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eAutologin function for any Niagara 4 system: MAC36NL, JACE8000, N4 Supervisor.¬†\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSetup Wizard¬†\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e Kiosk mode.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYou can connect it to iSMA-B-MAC36NL, JACE or other supervisor powered by Niagara 4 to display graphics by the web page from the Niagara system.\u003cbr\u003eAs a Panel PC with Android, it can be also used as User\u003cbr\u003eInterface. You can install a dedicated application that will\u003cbr\u003eallow communication with other devices in BMS\u003cbr\u003ethe system, for example, our Android application designed for connectivity with Niagara station. The Aspect Ratio 16:9 with resolution 1366x768 allows\u003cbr\u003efor displaying graphics clearly. The panel can be built into the wall, it is compatible with VESA. The panel has an extensive menu in 7 languages, in which we can customize the displayed image.\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ch3\u003eDisplay\u003c\/h3\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cul\u003e\n\u003cli\u003eSize 10,1‚Äô‚Äô\u003c\/li\u003e\n\u003cli\u003eAspect Ratio 16:9\u003c\/li\u003e\n\u003cli\u003eResolution 1366x768\u003c\/li\u003e\n\u003cli\u003eContrast 800:1\u003c\/li\u003e\n\u003cli\u003eLuminance 300 nit, up to 800 nit\u003c\/li\u003e\n\u003cli\u003eResponse time 5 ms\u003c\/li\u003e\n\u003cli\u003eActive Area (mm) 222.7x125.2\u003c\/li\u003e\n\u003cli\u003eDisplay colours 16,7 M (8-bit)\u003c\/li\u003e\n\u003cli\u003eView angle 75\/75\/75\/75\u003c\/li\u003e\n\u003cli\u003e10-point capacitive touch screen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-D-PA\/\" title=\"Documentation \u0026amp; Downloads for iSMA-D-PA10C-B1-UK\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-D-PA10C-B1-UK style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-D-PA10C-B1-UK\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-D-PA\/\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321648701595,"sku":"iSMA-D-PA10C-B1-UK","price":1398.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/files\/isma-d-pa10-1.png?v=1737467256"},{"product_id":"isma-b-wexta","title":"iSMA-B-WEXTA","description":"\u003ch5\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #666666; font-family: 'Open Sans', sans-serif; font-style: normal; font-variant: normal; letter-spacing: normal; line-height: 20px; text-align: start; text-indent: 0px; text-transform: none; white-space: normal; widows: 1; word-spacing: 0px; -webkit-text-stroke-width: 0px; float: none; background-color: #ffffff; display: inline !important;\"\u003eAbout the product\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #666666; font-family: 'Open Sans', sans-serif; font-size: 14px; font-style: normal; font-variant: normal; font-weight: normal; letter-spacing: normal; line-height: 20px; orphans: auto; text-align: start; text-indent: 0px; text-transform: none; white-space: normal; widows: 1; word-spacing: 0px; -webkit-text-stroke-width: 0px; display: inline !important; float: none; background-color: #ffffff;\"\u003eiSMA-B-W0202 optional antenna - signal gain 5 dBi\u003c\/span\u003e.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-W0202\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-W0202\/\" target=\"_blank\"\u003e\u003cimg style=\"float: none;\" alt=\"Documentation \u0026amp; Downloads for iSMA-B-W0202\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\"\u003e\u003c\/a\u003e \u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-W0202\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-W0202\/\" target=\"_blank\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321698803867,"sku":"iSMA-B-WEXTA","price":12.0,"currency_code":"EUR","in_stock":true}]},{"product_id":"isma-b-mac36nl-ho","title":"iSMA-B-MAC36NL-HO","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAbout the product¬†\u003c\/h5\u003e\n\u003cp\u003eThe¬†iSMA-B-MAC36NL-HO is the hardware only version of the MAC36NL. It comes \u003cstrong\u003ewith\u003c\/strong\u003e SD card and no licence. This is particularly useful if you¬†need the hardware beforehand and licence it only when you need to, thus reducing any risks of ordering a bigger licence.¬†\u003c\/p\u003e\n\u003cp\u003eThe iSMA-B-MAC36NL is a compact Master Application Controller with built-in different types of I\/O and operating in Niagara Framework environment. Using the specific local I\/O set 16x UI, 8x AO, 4xDI and 8x DO allows to use the device in different applications. The controller provides control, data logging, alarming, scheduling, integration and visualisation.\u003c\/p\u003e\n\u003cp\u003eTo allow IP connectivity there are 2x Fast Ethernet ports which can operate as two independent ports. Built-in 1x RS485 can be used to expand number of I\/O by connecting MINI or MIX series I\/O modules or to integrate with other subsystems.\u003cbr\u003eiSMA-B-MAC36NL provides rich graphical interface displaying on a standard Web browser or on external display connected to built-in HDMI and USB port (touch-screen support).\u003cbr\u003e\u003cspan\u003eThere are two more hardware versions of the controller with the¬†\u003c\/span\u003e\u003cstrong\u003esecond RS485\u003c\/strong\u003e\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003eport\u003c\/strong\u003e\u003cspan\u003e¬†and¬†\u003c\/span\u003e\u003cstrong\u003eM-Bus interface\u003c\/strong\u003e\u003cspan\u003e¬†available.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003eThe Niagara versions available for this controller in the latest \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\/Niagara\/\"\u003eInstaller\u003c\/a\u003e version:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNiagara 4.4.73 (not recommended)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.4.92 (not recommended)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.6.96.28\u003c\/li\u003e\n\u003cli\u003eNiagara 4.7.109.20\u003c\/li\u003e\n\u003cli\u003eNiagara 4.8.0.110\u003c\/li\u003e\n\u003cli\u003eNiagara 4.9.0.198 (Use the installer v1.4)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.9.1.30\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.0.154 (Use the installer v1.5)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.1.36 (Use the installer v1.7)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.3.20\u003c\/li\u003e\n\u003cli\u003eNiagara 4.11.1.16\u003c\/li\u003e\n\u003cli\u003eNiagara 4.12.0.156 (Use the installer v1.8)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.12.2.16\u003c\/li\u003e\n\u003cli\u003eNiagara 4.13.2.18.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBACnet MSTP, Data Recovery Service, Web Service Ports fix and HDMI function are now available for N4.6 and higher.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eFor all new features and improvements, please see the \u003c\/span\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\/Release_Note\"\u003eRelease Notes\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMain features\u003cbr\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv style=\"text-align: justify;\" class=\"col-sm-6\"\u003e\n\u003cstrong\u003e16x Universal Inputs (16UI)\u003c\/strong\u003e\n\u003cp\u003eAll Universal Inputs have 16-bit ADC which support the following types of inputs:\u003cbr\u003eTemperature input supports the following types of sensors:\u003cbr\u003e10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1, Pt1000, Ni1000\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFor sensors Pt1000 and Ni1000 use only 16-bit resolution!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage input 0-10 V DC: input resistance 100 kŒ© accuracy ¬±0,1%, measurement resolution 3 mV @ 12-bit\u003cbr\u003eand 1 mV @ 16-bit\u003c\/li\u003e\n\u003cli\u003eCurrent input 0-20 mA (external resistor¬†200 Œ© required)\u003c\/li\u003e\n\u003cli\u003eResistive input 0-1000 kŒ©: measurement resolution\u003cbr\u003efor 20 kŒ© load: 20 Œ© @ 12-bit and 1 Œ© @ 16-bit\u003c\/li\u003e\n\u003cli\u003eDry contact input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e4x Digital Inputs (4DI)\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eDry contact inputs\u003c\/li\u003e\n\u003cli\u003eFast pulse counter up to 100 Hz saved in SD Card\u003c\/li\u003e\n\u003c\/ul\u003e\n8x Analog Outputs (8AO)\n\u003cp\u003eAll Analog Outputs are equipped with 12-bit ADC provides 10 mV resolution and accuracy less than ¬±0,5%. They support the following output types:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage: 0-10 V DC max. load up to 20 mA\u003c\/li\u003e\n\u003cli\u003ePWM: 0,01 Hz, 0,1 Hz, 1 Hz, 10 Hz, 100 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e8x Digital Outputs (8DO) \u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eRelay output (NO): max. 3 A @ 30 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-6\"\u003e\n\u003cstrong\u003ePlatform\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eMulticore Cortex-A Series ARM Processor\u003c\/li\u003e\n\u003cli\u003e1GB DDR3 SDRAM\u003c\/li\u003e\n\u003cli\u003eRemovable micro-SD card ‚Äì 4 GB\u003cbr\u003e(2 GB system reserved \/ 2 GB user storage)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eCommunication \u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003eRS485 half-duplex, opto-isolated\u003c\/li\u003e\n\u003cli\u003eBaud rate from 2400 to 115200\u003c\/li\u003e\n\u003cli\u003e2x Fast Ethernet (independent)\u003c\/li\u003e\n\u003cli\u003e2x USB (1x OTG, 1x Host)\u003c\/li\u003e\n\u003cli\u003eHDMI type A (standard)\u003c\/li\u003e\n\u003cli\u003eMicro SD card slot\u003c\/li\u003e\n\u003cli\u003eModbus RTU\/ASCII\/IP, BACnet MSTP\/IP, oBIX, SNMP,\u003cbr\u003eLON\/IP, KNX\/IP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003ePower supply \u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003e24 V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eHousing\u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003eDimensions: 160x110x62 mm.\u003c\/li\u003e\n\u003cli\u003eConstruction: UL approved,\u003cbr\u003eself-extinguishing plastic (PC\/ABS)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting DIN (DIN EN 50022 norm)\u003c\/li\u003e\n\u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: justify;\"\u003eOperating temperature: -10¬∞C to 50¬∞C\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eStorage temperature: -40¬∞C to 85¬∞C\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eRelative humidity: 5% to 95%, no condensation\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eIngress Protection Rating: IP40 ‚Äì for indoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\n\u003cstrong\u003e\u003c\/strong\u003e¬†\u003c\/h5\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003cdiv\u003e\n\u003ch4\u003eProduct Informations\u003c\/h4\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat is the default IP of the device?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe default IP is : 192.168.1.123.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat Niagara version is needed to connect to this controller?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eAt the moment the¬†default Niagara version is N4.4 (4.4.73.24).\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat should I do if I need to use Niagara 4.4.92.2?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eTo install dist you can either copy the \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/iSMA-MAC36_nre_4.4.92.2\/\"\u003eDIST FILES \u003c\/a\u003eto your¬†\u003cbr\u003e%HOMEPATH%\\Niagara4.4\\sw\\inbox folder and use commisioning wizard, or use Platform‚ÜíDistribution File Installer, choose file and install.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat should I do if I need to use Niagara 4.6 and 4.7?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e¬†Please download the 4.6 and 4.7 update files¬†\u003cspan style=\"color: #0000ff;\"\u003e\u003ca style=\"color: #0000ff;\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/iSMA-MAC36_nre_4.6%264.7\/\"\u003eHERE\u003c\/a\u003e\u003c\/span\u003e, into the zipfile you will find a file named ‚ÄúiSMA_MAC36_files_installer_v1.0.945‚Äù, this will copy for you all the DIST files into the relevant folders.After this procedure you will need to restart the Workplace and commission your MAC36NL with the 4.6 or 4.7 version.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat¬†are the¬†improvements for the MAC36NL¬†with¬†Niagara 4.6 and 4.7?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eWith the release of N4.6 and N4.7 for the MAC36NL you some new features:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eBACnet MSTP\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eData Recovery Service\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWeb Service Port Fix\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\nPlease see read the \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Release_Note\/iSMA-B-MAC36NL_Release_Notes.pdf\"\u003eRelease Notes\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat are the default platform Credentials?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe default credentials are the same as to the Tridium controllers:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003eUser: tridium\u003c\/p\u003e\n\u003cp\u003ePassword:niagara\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat communication networks are available?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eIn this stage the Networks that work are:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e- Modbus RS485\u003c\/p\u003e\n\u003cp\u003e- Modbus TCP\u003c\/p\u003e\n\u003cp\u003e- BACnet TCP\u003c\/p\u003e\n\u003cp\u003e- BACnet MSTP available for version N4.6 and N4.7.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e-¬†Mbus TCP\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e- Niagara Network\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat features are implemented into this controller compared to the Tridium Jace?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe iSMA has the same features as a Tridium N4 controller:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e-Alarm\u003c\/p\u003e\n\u003cp\u003e-Histories\u003c\/p\u003e\n\u003cp\u003e-PX pages (web User Interface pages) HTML 5 web viewing\u003c\/p\u003e\n\u003cp\u003e-Communication with Niagara controllers and Supervisors through Niagara Network\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhen commissioning I see this message: there is no Core software found that can be installed, what should I do?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe core software is installed from the factoryfor version 4.4.73, you just need to press Next.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eAfter using the commissioning wizard to install the Station and modules, I can see into the Application Directory that there are errors regarding the Web Server and I cannot access the controller from the webpage. How do I resolve that error and access the controller through the web page?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eAt this stage the Web server works with the TCP port above 1024, so you will need to go and change the HTTP and HTTPs ports to be above 1024 (ex: HTTP port - 8080, HTTPs port 8443).\u003cspan\u003e¬†After setting this up please restart the station. \u003cstrong\u003eThis issue was resolved in N4.6 and N4.7 release.\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow does the Local IOs work?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe Local IO driver it is still at an early stage and you will need to Download the¬†\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca style=\"color: #0000ff; text-decoration: underline;\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/iSMAIO.zip\"\u003eJar file.\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e¬†Put it into the Modules folder and restart the Workbench. Go and find the iSMA IO into the Palette.\u003c\/div\u003e\n\u003cdiv class=\"qs-content\"\u003eInto the Drivers add from the iSMA_IO Palette the iSMA IO Network, after that open the Property Sheet of the Drivers to see the recently added Network. Under it add the Local IO Device and under that add the points from the palette.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow do I change the Universal Input type?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eOpen the property sheet of the UI and you will see the Input type property, by default it is set to Voltage.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow do I change the Analog Output type?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eOpen the property sheet of the AO and you will see the Output type property, by default it is set to Voltage.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow can I use the HDMI function?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe manufacturer is currently testing the HDMI function and will release it in the next software update.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e¬†Do you have a question about this product?\u003c\/strong\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\" title=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-HO\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" alt=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-HO style=\" float:=\"\" none=\"\"\u003e\u003c\/a\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\" title=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-HO\"\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"gtx-trans\" style=\"position: absolute; left: 145px; top: 612.156px;\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321727836315,"sku":"iSMA-B-MAC36NL;iSMA-B-SD-NL","price":1406.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-B-MAC36NL-600x600.png?v=1737467158"},{"product_id":"isma-d-pd10c-b1-uk","title":"iSMA-D-PD10C-B1-UK","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eSay hello to the new iSMA HDMI display.\u003cbr\u003e\u003cbr\u003eNiagara 4 has impressive graphics capabilities, and now we have a new solution that will enhance your user interface even further. \u003cbr\u003e\u003cbr\u003eThe iSMA HDMI display is the world's first Niagara 4 BMS touchscreen that works directly with an HDMI connection. It is optimised to work seamlessly with the MAC36NL \u003cbr\u003e\u003cbr\u003eNo IP address required, no kiosk mode and no setup wizard. You plug in the HDMI cable, and the MAC36NL will automatically render the graphics onto the iSMA touchscreen.\u003cbr\u003e\u003cbr\u003eThen you connect the USB cable to the MAC36NL, and the controller will capture all your touch functions.\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003eThis module is fully compatible with any model of MAC36NL, first and second generation.\u003c\/span\u003e\u003cspan data-sheets-value='{\"1\":2,\"2\":\"Distech\"}' data-sheets-userformat='{\"2\":17153,\"3\":{\"1\":0},\"11\":4,\"12\":0,\"17\":1}'\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ch3\u003eDisplay\u003c\/h3\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cul\u003e\n\u003cli\u003eSize 10,1‚Äô‚Äô\u003c\/li\u003e\n\u003cli\u003eAspect Ratio 16:9\u003c\/li\u003e\n\u003cli\u003eResolution 1366x768\u003c\/li\u003e\n\u003cli\u003eContrast 800:1\u003c\/li\u003e\n\u003cli\u003eLuminance 300 nit, up to 800 nit\u003c\/li\u003e\n\u003cli\u003eResponse time 5 ms\u003c\/li\u003e\n\u003cli\u003eActive Area (mm) 222.7x125.2\u003c\/li\u003e\n\u003cli\u003eDisplay Colours 16,7 M (8-bit)\u003c\/li\u003e\n\u003cli\u003eView angle 75\/75\/75\/75\u003c\/li\u003e\n\u003cli\u003e10-point capacitive touch screen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eI\/O Interface\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHDMI\u003c\/li\u003e\n\u003cli\u003eVGA\u003c\/li\u003e\n\u003cli\u003eDVI\u003c\/li\u003e\n\u003cli\u003eI\/O Audio\u003c\/li\u003e\n\u003cli\u003eRJ45-USB for touch input\u003c\/li\u003e\n\u003cli\u003eDC 12-24 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eInterface\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt-in 7 languages - English, French, German, Spanish,\u003cbr\u003eChinese, Italian, Russian\u003c\/li\u003e\n\u003cli\u003eMenu for changing image settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003ePower\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower supply: AC 110-240 V, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003ePanel power input: DC 12 V-24 V\u003c\/li\u003e\n\u003cli\u003ePower consumption: ‚â§ 30 W\u003c\/li\u003e\n\u003cli\u003ePower standby: ‚â§ 1.5 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with VESA\u003c\/li\u003e\n\u003cli\u003eFor embedding\u003c\/li\u003e\n\u003cli\u003eWall Mount\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003ch3\u003eHousing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDimension: 293,6x193,6x48,5 mm (11.560x7.622x1.909\u003cbr\u003ein)\u003c\/li\u003e\n\u003cli\u003eConstruction: Aluminum alloy enclosure, colour black\u003c\/li\u003e\n\u003cli\u003eBezel thickness 3 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ch3\u003eEnvironment\u003c\/h3\u003e\n\u003cspan\u003e\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature: -10¬∞C to 60¬∞C (14¬∞F to 140¬∞F)\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -10¬∞C to 60¬∞C (14¬∞F to 140¬∞F)\u003c\/li\u003e\n\u003cli\u003eOperation humidity: 10% to 80%\u003c\/li\u003e\n\u003cli\u003eStorage humidity: 10% to 90%\u003c\/li\u003e\n\u003cli\u003eIngress Protection Rating: IP65 ‚Äì for front panel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.innon.com\/pages\/io-calculator\" title=\"IO Module Calculator\" target=\"_blank\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1144\/2302\/files\/savetime_iomodulecalculator_befcd269-34ad-4c89-9af0-0abd90d65a73_grande.png?v=1526993647\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-D-PD10C-B1\/\" title=\"Documentation \u0026amp; Downloads for iSMA-D-PD10C-B1-UK\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-D-PD10C-B1-UK style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-D-PD10C-B1-UK\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-D-PD10C-B1\/\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321755754651,"sku":"iSMA-D-PD10C-B1-UK","price":1000.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/files\/isma-d-pa10-1.png?v=1737467256"},{"product_id":"isma-b-mac36nl-rs-250","title":"iSMA-B-MAC36NL-RS-250","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eThe iSMA-B-MAC36NL is Niagara controller with 36 onboard IO and license of 250 points and¬†two RS485 port. If more points are needed then you can upgrade in 50 points increment.\u003c\/p\u003e\n\u003cp\u003eThe MAC (Master Application Controller) with built-in different types of I\/O and operating in the Niagara Framework environment. Using the specific local I\/O set 16x UI, 8x AO, 4xDI and 8x DO allow to use the device in different applications. The controller provides control, data logging, alarming, scheduling, integration and visualisation.\u003c\/p\u003e\n\u003cp\u003eTo allow IP connectivity there are 2x Fast Ethernet ports which can operate as two independent ports. Built-in 2x RS485 can be used to expand number of I\/O by connecting MINI or MIX series I\/O modules or to integrate with other subsystems.\u003cbr\u003eiSMA-B-MAC36NL provides rich graphical interface displaying on a standard Web browser or on external display connected to built-in HDMI and USB port (touch-screen support).\u003cbr\u003e\u003cspan\u003eThere are two more hardware versions of the controller available: standard¬†\u003c\/span\u003e\u003cstrong\u003eiSMA-B-MAC36NL\u003c\/strong\u003e\u003cspan\u003e¬†and with¬†\u003c\/span\u003e\u003cstrong\u003eM-Bus interface\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003eThe Niagara versions available for this controller in the latest \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\/Niagara\/\"\u003eInstaller\u003c\/a\u003e version:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNiagara 4.4.73 (not recommended)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.4.92 (not recommended)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.6.96.28 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.7.109.20 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.8.0.110 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.9.0.198 (Use the installer v1.4)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.9.1.30 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.0.154 (Use the installer v1.5)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.1.36 (Use the installer v1.7)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.3.20  (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.11.1.16 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.12.0.156 (Use the installer v1.8)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.12.2.16 (Use the installer v1.9)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.7.42.1\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.9.14.1\u003c\/li\u003e\n\u003cli\u003eNiagara 4.13.2.18\u003c\/li\u003e\n\u003cli\u003eNiagara 4.14.0.162\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBACnet MSTP, Data Recovery Service, Web Service Ports fix and HDMI function are now available for N4.6 and higher.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eFor all new features and improvements, please see the \u003c\/span\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\/Release_Note\"\u003eRelease Notes\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMain features\u003cbr\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv style=\"text-align: justify;\" class=\"col-sm-6\"\u003e\n\u003cstrong\u003e16x Universal Inputs (16UI)\u003c\/strong\u003e\n\u003cp\u003eAll Universal Inputs have 16-bit ADC which support the following types of inputs:\u003cbr\u003eTemperature input supports the following types of sensors:\u003cbr\u003e10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1, Pt1000, Ni1000\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFor sensors Pt1000 and Ni1000 use only 16-bit resolution!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage input 0-10 V DC: input resistance 100 kŒ© accuracy ¬±0,1%, measurement resolution 3 mV @ 12-bit\u003cbr\u003eand 1 mV @ 16-bit\u003c\/li\u003e\n\u003cli\u003eCurrent input 0-20 mA (external resistor¬†200 Œ© required)\u003c\/li\u003e\n\u003cli\u003eResistive input 0-1000 kŒ©: measurement resolution\u003cbr\u003efor 20 kŒ© load: 20 Œ© @ 12-bit and 1 Œ© @ 16-bit\u003c\/li\u003e\n\u003cli\u003eDry contact input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e4x Digital Inputs (4DI)\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eDry contact inputs\u003c\/li\u003e\n\u003cli\u003eFast pulse counter up to 100 Hz saved in SD Card\u003c\/li\u003e\n\u003c\/ul\u003e\n8x Analog Outputs (8AO)\n\u003cp\u003eAll Analog Outputs are equipped with 12-bit ADC provides 10 mV resolution and accuracy less than ¬±0,5%. They support the following output types:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage: 0-10 V DC max. load up to 20 mA\u003c\/li\u003e\n\u003cli\u003ePWM: 0,01 Hz, 0,1 Hz, 1 Hz, 10 Hz, 100 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e8x Digital Outputs (8DO) \u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eRelay output (NO): max. 3 A @ 30 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-6\"\u003e\n\u003cstrong\u003ePlatform\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eMulticore Cortex-A Series ARM Processor\u003c\/li\u003e\n\u003cli\u003e1GB DDR3 SDRAM\u003c\/li\u003e\n\u003cli\u003eRemovable micro-SD card ‚Äì 4 GB\u003cbr\u003e(2 GB system reserved \/ 2 GB user storage)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eCommunication \u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003eRS485 half-duplex, opto-isolated\u003c\/li\u003e\n\u003cli\u003eBaud rate from 2400 to 115200\u003c\/li\u003e\n\u003cli\u003e2x Fast Ethernet (independent)\u003c\/li\u003e\n\u003cli\u003e2x USB (1x OTG, 1x Host)\u003c\/li\u003e\n\u003cli\u003eHDMI type A (standard)\u003c\/li\u003e\n\u003cli\u003eMicro SD card slot\u003c\/li\u003e\n\u003cli\u003eModbus RTU\/ASCII\/IP, BACnet MSTP\/IP, oBIX, SNMP,\u003cbr\u003eLON\/IP, KNX\/IP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003ePower supply \u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003e24 V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eHousing\u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003eDimensions: 160x110x62 mm.\u003c\/li\u003e\n\u003cli\u003eConstruction: UL approved,\u003cbr\u003eself-extinguishing plastic (PC\/ABS)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting DIN (DIN EN 50022 norm)\u003c\/li\u003e\n\u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: justify;\"\u003eOperating temperature: -10¬∞C to 50¬∞C\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eStorage temperature: -40¬∞C to 85¬∞C\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eRelative humidity: 5% to 95%, no condensation\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eIngress Protection Rating: IP40 ‚Äì for indoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\n\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/a\u003eProduct Informations\u003c\/h5\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003cdiv\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat is the default IP of the device?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe default IP is : 192.168.1.123.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat Niagara version is needed to connect to this controller?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eAt the moment the¬†default Niagara version is N4.4 (4.4.73.24).\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat should I do if I need to use Niagara 4.4.92.2?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eTo install dist you can either copy the \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/Precious%20Versions\/iSMA-MAC36_nre_4.4.92.2\/\"\u003eDIST FILES\u003c\/a\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/iSMA-MAC36_nre_4.4.92.2\/\"\u003e \u003c\/a\u003eto your¬†\u003cbr\u003e%HOMEPATH%\\Niagara4.4\\sw\\inbox folder and use commisioning wizard, or use Platform‚ÜíDistribution File Installer, choose file and install.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat should I do if I need to use Niagara 4.6, 4.7 or 4.8?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e¬†Please download the¬†latest update files¬†\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eHERE\u003c\/span\u003e\u003c\/a\u003e, into the zipfile, which contains the DIST files for version 4.6, 4.7 and 4.8. You will find a file named ‚ÄúiSMA_MAC36_files_installer_v1.0.1152.bat‚Äù, this will copy for you all the DIST files into the relevant folders. After this procedure you will need to restart the Workplace and commission your MAC36NL with the 4.6, 4.7 or 4.8 version.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf you need to upgrade to 4.8\u003c\/span\u003e\u003cspan\u003e¬†and¬†\u003c\/span\u003e\u003cspan\u003ethe controller is already running on¬†lower versions (4.4, 4.6¬†or 4.7) the first step you will need\u003c\/span\u003e\u003cspan\u003e¬†to do is¬†\u003c\/span\u003e\u003cspan\u003eto clean the controller¬†by installing the CleanDist file using the Distribution¬†\u003c\/span\u003e\u003cspan\u003eF\u003c\/span\u003e\u003cspan\u003eile¬†\u003c\/span\u003e\u003cspan\u003eI\u003c\/span\u003e\u003cspan\u003enstaller from the controller's platform and after that commission the MAC36NL controller with the 4.8.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat¬†are the¬†improvements for the MAC36NL¬†with¬†Niagara 4.6 and 4.7?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eWith the release of N4.6 and N4.7 for the MAC36NL you some new features:\u003c\/span\u003e\u003c\/p\u003e\n¬†- BACnet MSTP¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† -¬†HDMI\u003cbr\u003e¬†-¬†Data Recovery Service¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬†-¬†¬†\u003cspan\u003eWeb Service Port Fix\u003c\/span\u003e\u003cbr\u003ePlease see read the \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Release_Note\/iSMA-B-MAC36NL_Release_Notes.pdf\"\u003eRelease Notes\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\n\u003cspan style=\"color: #ff0000;\"\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row row-1\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat are the default platform Credentials?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe default credentials are the same as to the Tridium controllers:\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eUser: tridium\u003c\/p\u003e\n\u003cp\u003ePassword:niagara\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat communication networks are available?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eIn this stage the Networks that work are:\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e- Modbus RS485\u003c\/p\u003e\n\u003cp\u003e- Modbus TCP\u003c\/p\u003e\n\u003cp\u003e- BACnet TCP\u003c\/p\u003e\n\u003cp\u003e- BACnet MSTP available for version N4.6 and N4.7.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e-¬†Mbus TCP\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e- Niagara Network\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat features are implemented into this controller compared to the Tridium Jace?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe iSMA has the same features as a Tridium N4 controller:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e-Alarm\u003c\/p\u003e\n\u003cp\u003e-Histories\u003c\/p\u003e\n\u003cp\u003e-PX pages (web User Interface pages) HTML 5 web viewing\u003c\/p\u003e\n\u003cp\u003e-Communication with Niagara controllers and Supervisors through Niagara Network\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhen commissioning I see this message: there is no Core software found that can be installed, what should I do?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe core software is installed from the factoryfor version 4.4.73, you just need to press Next.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eAfter using the commissioning wizard to install the Station and modules, I can see into the Application Directory that there are errors regarding the Web Server and I cannot access the controller from the webpage. How do I resolve that error and access the controller through the web page?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eAt this stage the Web server works with the TCP port above 1024, so you will need to go and change the HTTP and HTTPs ports to be above 1024 (ex: HTTP port - 8080, HTTPs port 8443).\u003cspan\u003e¬†After setting this up please restart the station. \u003cstrong\u003eThis issue was resolved in N4.6 and N4.7 release.\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow does the Local IOs work?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe Local IO driver it is still at an early stage and you will need to Download the¬†\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca style=\"color: #0000ff; text-decoration: underline;\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/iSMAIO.zip\"\u003eJar file.\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e¬†Put it into the Modules folder and restart the Workbench. Go and find the iSMA IO into the Palette.\u003c\/div\u003e\n\u003cdiv class=\"qs-content\"\u003eInto the Drivers add from the iSMA_IO Palette the iSMA IO Network, after that open the Property Sheet of the Drivers to see the recently added Network. Under it add the Local IO Device and under that add the points from the palette.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow do I change the Universal Input type?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eOpen the property sheet of the UI and you will see the Input type property, by default it is set to Voltage.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow do I change the Analog Output type?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eOpen the property sheet of the AO and you will see the Output type property, by default it is set to Voltage.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow can I use the HDMI function?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003e\n\u003cdiv class=\"qs-content\"\u003eAfter you have commissioned the controller on your N4.6 or N4.7¬† and install the iSMA_HDMI jar file, copy the HDMI service from the iSMA_HDMI pallette to the Service folder and you will need to go to the WEB service and activate the HTTP port and disable HTTPS Only. After you make those settings please reboot the controller.¬†\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e \u003ca rel=\"noopener\" title=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-RS-250\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-RS-250‚Äù style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-RS-250\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\"\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"position: absolute; left: 145px; top: 572.969px;\" id=\"gtx-trans\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321760374939,"sku":"iSMA-B-MAC36NL-RS;iSMA-B-SD-NL","price":2190.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-B-MAC36-RS-600x600_3955c2e0-85d7-4348-a1e8-7e8852cf9cbe.png?v=1737467143"},{"product_id":"isma-b-sd-nl","title":"iSMA-B-SD-NL","description":"\u003cmeta charset=\"utf-8\"\u003e\n \u003ctable class=\"x-field x-table-plain x-form-item x-box-item x-field-default x-hbox-form-item\" id=\"display-1061\" cellpadding=\"0\"\u003e\n \u003ctbody\u003e\n \u003ctr id=\"display-1061-inputRow\"\u003e\n \u003ctd class=\"x-form-item-body \" id=\"display-1061-bodyEl\" colspan=\"2\" role=\"presentation\"\u003e\n \u003cdiv id=\"display-1061-inputEl\" class=\"x-form-display-field\" aria-invalid=\"false\" data-errorqtip=\"\"\u003eiSMA-B-SD-NL\u003c\/div\u003e\n \u003c\/td\u003e\n \u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321781051547,"sku":"iSMA-B-SD-NL","price":71.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/iSMA-B-SD-NL.png?v=1737467141"},{"product_id":"isma-b-mac36nl-rs-300","title":"iSMA-B-MAC36NL-RS-300","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eThe iSMA-B-MAC36NL is Niagara controller with 36 onboard IO and license of 300 points and¬†two RS485 port. If more points are needed then you can upgrade in 50 points increment.\u003c\/p\u003e\n\u003cp\u003eThe MAC (Master Application Controller) with built-in different types of I\/O and operating in the Niagara Framework environment. Using the specific local I\/O set 16x UI, 8x AO, 4xDI and 8x DO allow to use the device in different applications. The controller provides control, data logging, alarming, scheduling, integration and visualisation.\u003c\/p\u003e\n\u003cp\u003eTo allow IP connectivity there are 2x Fast Ethernet ports which can operate as two independent ports. Built-in 2x RS485 can be used to expand number of I\/O by connecting MINI or MIX series I\/O modules or to integrate with other subsystems.\u003cbr\u003eiSMA-B-MAC36NL provides rich graphical interface displaying on a standard Web browser or on external display connected to built-in HDMI and USB port (touch-screen support).\u003cbr\u003e\u003cspan\u003eThere are two more hardware versions of the controller available: standard¬†\u003c\/span\u003e\u003cstrong\u003eiSMA-B-MAC36NL\u003c\/strong\u003e\u003cspan\u003e¬†and with¬†\u003c\/span\u003e\u003cstrong\u003eM-Bus interface\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003eThe Niagara versions available for this controller in the latest \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\/Niagara\/\"\u003eInstaller\u003c\/a\u003e version:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNiagara 4.4.73 (not recommended)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.4.92 (not recommended)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.6.96.28 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.7.109.20 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.8.0.110 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.9.0.198 (Use the installer v1.4)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.9.1.30 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.0.154 (Use the installer v1.5)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.1.36 (Use the installer v1.7)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.3.20  (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.11.1.16 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.12.0.156 (Use the installer v1.8)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.12.2.16 (Use the installer v1.9)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.7.42.1\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.9.14.1\u003c\/li\u003e\n\u003cli\u003eNiagara 4.13.2.18\u003c\/li\u003e\n\u003cli\u003eNiagara 4.14.0.162\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBACnet MSTP, Data Recovery Service, Web Service Ports fix and HDMI function are now available for N4.6 and higher.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eFor all new features and improvements, please see the \u003c\/span\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\/Release_Note\"\u003eRelease Notes\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMain features\u003cbr\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv style=\"text-align: justify;\" class=\"col-sm-6\"\u003e\n\u003cstrong\u003e16x Universal Inputs (16UI)\u003c\/strong\u003e\n\u003cp\u003eAll Universal Inputs have 16-bit ADC which support the following types of inputs:\u003cbr\u003eTemperature input supports the following types of sensors:\u003cbr\u003e10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1, Pt1000, Ni1000\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFor sensors Pt1000 and Ni1000 use only 16-bit resolution!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage input 0-10 V DC: input resistance 100 kŒ© accuracy ¬±0,1%, measurement resolution 3 mV @ 12-bit\u003cbr\u003eand 1 mV @ 16-bit\u003c\/li\u003e\n\u003cli\u003eCurrent input 0-20 mA (external resistor¬†200 Œ© required)\u003c\/li\u003e\n\u003cli\u003eResistive input 0-1000 kŒ©: measurement resolution\u003cbr\u003efor 20 kŒ© load: 20 Œ© @ 12-bit and 1 Œ© @ 16-bit\u003c\/li\u003e\n\u003cli\u003eDry contact input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e4x Digital Inputs (4DI)\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eDry contact inputs\u003c\/li\u003e\n\u003cli\u003eFast pulse counter up to 100 Hz saved in SD Card\u003c\/li\u003e\n\u003c\/ul\u003e\n8x Analog Outputs (8AO)\n\u003cp\u003eAll Analog Outputs are equipped with 12-bit ADC provides 10 mV resolution and accuracy less than ¬±0,5%. They support the following output types:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage: 0-10 V DC max. load up to 20 mA\u003c\/li\u003e\n\u003cli\u003ePWM: 0,01 Hz, 0,1 Hz, 1 Hz, 10 Hz, 100 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e8x Digital Outputs (8DO) \u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eRelay output (NO): max. 3 A @ 30 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-6\"\u003e\n\u003cstrong\u003ePlatform\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eMulticore Cortex-A Series ARM Processor\u003c\/li\u003e\n\u003cli\u003e1GB DDR3 SDRAM\u003c\/li\u003e\n\u003cli\u003eRemovable micro-SD card ‚Äì 4 GB\u003cbr\u003e(2 GB system reserved \/ 2 GB user storage)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eCommunication \u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003eRS485 half-duplex, opto-isolated\u003c\/li\u003e\n\u003cli\u003eBaud rate from 2400 to 115200\u003c\/li\u003e\n\u003cli\u003e2x Fast Ethernet (independent)\u003c\/li\u003e\n\u003cli\u003e2x USB (1x OTG, 1x Host)\u003c\/li\u003e\n\u003cli\u003eHDMI type A (standard)\u003c\/li\u003e\n\u003cli\u003eMicro SD card slot\u003c\/li\u003e\n\u003cli\u003eModbus RTU\/ASCII\/IP, BACnet MSTP\/IP, oBIX, SNMP,\u003cbr\u003eLON\/IP, KNX\/IP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003ePower supply \u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003e24 V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eHousing\u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003eDimensions: 160x110x62 mm.\u003c\/li\u003e\n\u003cli\u003eConstruction: UL approved,\u003cbr\u003eself-extinguishing plastic (PC\/ABS)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting DIN (DIN EN 50022 norm)\u003c\/li\u003e\n\u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: justify;\"\u003eOperating temperature: -10¬∞C to 50¬∞C\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eStorage temperature: -40¬∞C to 85¬∞C\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eRelative humidity: 5% to 95%, no condensation\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eIngress Protection Rating: IP40 ‚Äì for indoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\n\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/a\u003eProduct Informations\u003c\/h5\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003cdiv\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat is the default IP of the device?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe default IP is : 192.168.1.123.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat Niagara version is needed to connect to this controller?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eAt the moment the¬†default Niagara version is N4.4 (4.4.73.24).\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat should I do if I need to use Niagara 4.4.92.2?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eTo install dist you can either copy the \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/Precious%20Versions\/iSMA-MAC36_nre_4.4.92.2\/\"\u003eDIST FILES\u003c\/a\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/iSMA-MAC36_nre_4.4.92.2\/\"\u003e \u003c\/a\u003eto your¬†\u003cbr\u003e%HOMEPATH%\\Niagara4.4\\sw\\inbox folder and use commisioning wizard, or use Platform‚ÜíDistribution File Installer, choose file and install.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat should I do if I need to use Niagara 4.6, 4.7 or 4.8?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e¬†Please download the¬†latest update files¬†\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eHERE\u003c\/span\u003e\u003c\/a\u003e, into the zipfile, which contains the DIST files for version 4.6, 4.7 and 4.8. You will find a file named ‚ÄúiSMA_MAC36_files_installer_v1.0.1152.bat‚Äù, this will copy for you all the DIST files into the relevant folders. After this procedure you will need to restart the Workplace and commission your MAC36NL with the 4.6, 4.7 or 4.8 version.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf you need to upgrade to 4.8\u003c\/span\u003e\u003cspan\u003e¬†and¬†\u003c\/span\u003e\u003cspan\u003ethe controller is already running on¬†lower versions (4.4, 4.6¬†or 4.7) the first step you will need\u003c\/span\u003e\u003cspan\u003e¬†to do is¬†\u003c\/span\u003e\u003cspan\u003eto clean the controller¬†by installing the CleanDist file using the Distribution¬†\u003c\/span\u003e\u003cspan\u003eF\u003c\/span\u003e\u003cspan\u003eile¬†\u003c\/span\u003e\u003cspan\u003eI\u003c\/span\u003e\u003cspan\u003enstaller from the controller's platform and after that commission the MAC36NL controller with the 4.8.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat¬†are the¬†improvements for the MAC36NL¬†with¬†Niagara 4.6 and 4.7?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eWith the release of N4.6 and N4.7 for the MAC36NL you some new features:\u003c\/span\u003e\u003c\/p\u003e\n¬†- BACnet MSTP¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† -¬†HDMI\u003cbr\u003e¬†-¬†Data Recovery Service¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬†-¬†¬†\u003cspan\u003eWeb Service Port Fix\u003c\/span\u003e\u003cbr\u003ePlease see read the \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Release_Note\/iSMA-B-MAC36NL_Release_Notes.pdf\"\u003eRelease Notes\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\n\u003cspan style=\"color: #ff0000;\"\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row row-1\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat are the default platform Credentials?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe default credentials are the same as to the Tridium controllers:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003eUser: tridium\u003c\/p\u003e\n\u003cp\u003ePassword:niagara\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat communication networks are available?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eIn this stage the Networks that work are:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e- Modbus RS485\u003c\/p\u003e\n\u003cp\u003e- Modbus TCP\u003c\/p\u003e\n\u003cp\u003e- BACnet TCP\u003c\/p\u003e\n\u003cp\u003e- BACnet MSTP available for version N4.6 and N4.7.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e-¬†Mbus TCP\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e- Niagara Network\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat features are implemented into this controller compared to the Tridium Jace?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe iSMA has the same features as a Tridium N4 controller:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e-Alarm\u003c\/p\u003e\n\u003cp\u003e-Histories\u003c\/p\u003e\n\u003cp\u003e-PX pages (web User Interface pages) HTML 5 web viewing\u003c\/p\u003e\n\u003cp\u003e-Communication with Niagara controllers and Supervisors through Niagara Network\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhen commissioning I see this message: there is no Core software found that can be installed, what should I do?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe core software is installed from the factoryfor version 4.4.73, you just need to press Next.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eAfter using the commissioning wizard to install the Station and modules, I can see into the Application Directory that there are errors regarding the Web Server and I cannot access the controller from the webpage. How do I resolve that error and access the controller through the web page?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eAt this stage the Web server works with the TCP port above 1024, so you will need to go and change the HTTP and HTTPs ports to be above 1024 (ex: HTTP port - 8080, HTTPs port 8443).\u003cspan\u003e¬†After setting this up please restart the station. \u003cstrong\u003eThis issue was resolved in N4.6 and N4.7 release.\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow does the Local IOs work?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe Local IO driver it is still at an early stage and you will need to Download the¬†\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca style=\"color: #0000ff; text-decoration: underline;\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/iSMAIO.zip\"\u003eJar file.\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e¬†Put it into the Modules folder and restart the Workbench. Go and find the iSMA IO into the Palette.\u003c\/div\u003e\n\u003cdiv class=\"qs-content\"\u003eInto the Drivers add from the iSMA_IO Palette the iSMA IO Network, after that open the Property Sheet of the Drivers to see the recently added Network. Under it add the Local IO Device and under that add the points from the palette.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow do I change the Universal Input type?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eOpen the property sheet of the UI and you will see the Input type property, by default it is set to Voltage.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow do I change the Analog Output type?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eOpen the property sheet of the AO and you will see the Output type property, by default it is set to Voltage.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow can I use the HDMI function?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003e\n\u003cdiv class=\"qs-content\"\u003eAfter you have commissioned the controller on your N4.6 or N4.7¬† and install the iSMA_HDMI jar file, copy the HDMI service from the iSMA_HDMI pallette to the Service folder and you will need to go to the WEB service and activate the HTTP port and disable HTTPS Only. After you make those settings please reboot the controller.¬†\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"faq-section\"\u003e\n\u003cdiv class=\"question-v1\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003cdiv class=\"qs-content\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\" target=\"_blank\" title=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-RS-300\" rel=\"noopener\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-RS-300‚Äù style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-RS-300\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\"\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"position: absolute; left: 145px; top: 524.969px;\" id=\"gtx-trans\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321784033435,"sku":"iSMA-B-MAC36NL-RS;iSMA-B-SD-NL","price":2494.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-B-MAC36-RS-600x600_6a1a3cd2-99fc-4a3e-b580-345da8192fe9.png?v=1737467139"},{"product_id":"isma-b-mac36nl-rs-150","title":"iSMA-B-MAC36NL-RS-150","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eThe iSMA-B-MAC36NL is Niagara controller with 36 onboard IO and license of 150 points and¬†two RS485 port. If more points are needed then you can upgrade in 50 points increment.\u003c\/p\u003e\n\u003cp\u003eThe MAC (Master Application Controller) with built-in different types of I\/O and operating in the Niagara Framework environment. Using the specific local I\/O set 16x UI, 8x AO, 4xDI and 8x DO allow to use the device in different applications. The controller provides control, data logging, alarming, scheduling, integration and visualisation.\u003c\/p\u003e\n\u003cp\u003eTo allow IP connectivity there are 2x Fast Ethernet ports which can operate as two independent ports. Built-in 2x RS485 can be used to expand number of I\/O by connecting MINI or MIX series I\/O modules or to integrate with other subsystems.\u003cbr\u003eiSMA-B-MAC36NL provides rich graphical interface displaying on a standard Web browser or on external display connected to built-in HDMI and USB port (touch-screen support).\u003cbr\u003e\u003cspan\u003eThere are two more hardware versions of the controller available: standard¬†\u003c\/span\u003e\u003cstrong\u003eiSMA-B-MAC36NL\u003c\/strong\u003e\u003cspan\u003e¬†and with¬†\u003c\/span\u003e\u003cstrong\u003eM-Bus interface\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003eThe Niagara versions available for this controller in the latest \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\/Niagara\/\"\u003eInstaller\u003c\/a\u003e version:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNiagara 4.4.73 (not recommended)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.4.92 (not recommended)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.6.96.28 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.7.109.20 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.8.0.110 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.9.0.198 (Use the installer v1.4)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.9.1.30 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.0.154 (Use the installer v1.5)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.1.36 (Use the installer v1.7)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.3.20  (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.11.1.16 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.12.0.156 (Use the installer v1.8)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.12.2.16 (Use the installer v1.9)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.7.42.1\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.9.14.1\u003c\/li\u003e\n\u003cli\u003eNiagara 4.13.2.18\u003c\/li\u003e\n\u003cli\u003eNiagara 4.14.0.162\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBACnet MSTP, Data Recovery Service, Web Service Ports fix and HDMI function are now available for N4.6 and higher.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eFor all new features and improvements, please see the \u003c\/span\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\/Release_Note\"\u003eRelease Notes\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMain features\u003cbr\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-6\" style=\"text-align: justify;\"\u003e\n\u003cstrong\u003e16x Universal Inputs (16UI)\u003c\/strong\u003e\n\u003cp\u003eAll Universal Inputs have 16-bit ADC which support the following types of inputs:\u003cbr\u003eTemperature input supports the following types of sensors:\u003cbr\u003e10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1, Pt1000, Ni1000\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFor sensors Pt1000 and Ni1000 use only 16-bit resolution!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage input 0-10 V DC: input resistance 100 kŒ© accuracy ¬±0,1%, measurement resolution 3 mV @ 12-bit\u003cbr\u003eand 1 mV @ 16-bit\u003c\/li\u003e\n\u003cli\u003eCurrent input 0-20 mA (external resistor¬†200 Œ© required)\u003c\/li\u003e\n\u003cli\u003eResistive input 0-1000 kŒ©: measurement resolution\u003cbr\u003efor 20 kŒ© load: 20 Œ© @ 12-bit and 1 Œ© @ 16-bit\u003c\/li\u003e\n\u003cli\u003eDry contact input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e4x Digital Inputs (4DI)\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eDry contact inputs\u003c\/li\u003e\n\u003cli\u003eFast pulse counter up to 100 Hz saved in SD Card\u003c\/li\u003e\n\u003c\/ul\u003e\n8x Analog Outputs (8AO)\n\u003cp\u003eAll Analog Outputs are equipped with 12-bit ADC provides 10 mV resolution and accuracy less than ¬±0,5%. They support the following output types:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage: 0-10 V DC max. load up to 20 mA\u003c\/li\u003e\n\u003cli\u003ePWM: 0,01 Hz, 0,1 Hz, 1 Hz, 10 Hz, 100 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e8x Digital Outputs (8DO) \u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eRelay output (NO): max. 3 A @ 30 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-6\"\u003e\n\u003cstrong\u003ePlatform\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eMulticore Cortex-A Series ARM Processor\u003c\/li\u003e\n\u003cli\u003e1GB DDR3 SDRAM\u003c\/li\u003e\n\u003cli\u003eRemovable micro-SD card ‚Äì 4 GB\u003cbr\u003e(2 GB system reserved \/ 2 GB user storage)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eCommunication \u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003eRS485 half-duplex, opto-isolated\u003c\/li\u003e\n\u003cli\u003eBaud rate from 2400 to 115200\u003c\/li\u003e\n\u003cli\u003e2x Fast Ethernet (independent)\u003c\/li\u003e\n\u003cli\u003e2x USB (1x OTG, 1x Host)\u003c\/li\u003e\n\u003cli\u003eHDMI type A (standard)\u003c\/li\u003e\n\u003cli\u003eMicro SD card slot\u003c\/li\u003e\n\u003cli\u003eModbus RTU\/ASCII\/IP, BACnet MSTP\/IP, oBIX, SNMP,\u003cbr\u003eLON\/IP, KNX\/IP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003ePower supply \u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003e24 V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eHousing\u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003eDimensions: 160x110x62 mm.\u003c\/li\u003e\n\u003cli\u003eConstruction: UL approved,\u003cbr\u003eself-extinguishing plastic (PC\/ABS)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting DIN (DIN EN 50022 norm)\u003c\/li\u003e\n\u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: justify;\"\u003eOperating temperature: -10¬∞C to 50¬∞C\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eStorage temperature: -40¬∞C to 85¬∞C\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eRelative humidity: 5% to 95%, no condensation\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eIngress Protection Rating: IP40 ‚Äì for indoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\n\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/a\u003e¬†\u003c\/h5\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003cdiv\u003e\n\u003ch4\u003eProduct Informations\u003c\/h4\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat is the default IP of the device?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe default IP is : 192.168.1.123.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat Niagara version is needed to connect to this controller?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eAt the moment the¬†default Niagara version is N4.4 (4.4.73.24).\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat should I do if I need to use Niagara 4.4.92.2?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eTo install dist you can either copy the \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/Precious%20Versions\/iSMA-MAC36_nre_4.4.92.2\/\"\u003eDIST FILES\u003c\/a\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/iSMA-MAC36_nre_4.4.92.2\/\"\u003e \u003c\/a\u003eto your¬†\u003cbr\u003e%HOMEPATH%\\Niagara4.4\\sw\\inbox folder and use commisioning wizard, or use Platform‚ÜíDistribution File Installer, choose file and install.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat should I do if I need to use Niagara 4.6, 4.7 or 4.8?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e¬†Please download the¬†latest update files¬†\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eHERE\u003c\/span\u003e\u003c\/a\u003e, into the zipfile, which contains the DIST files for version 4.6, 4.7 and 4.8. You will find a file named ‚ÄúiSMA_MAC36_files_installer_v1.0.1152.bat‚Äù, this will copy for you all the DIST files into the relevant folders. After this procedure you will need to restart the Workplace and commission your MAC36NL with the 4.6, 4.7 or 4.8 version.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf you need to upgrade to 4.8\u003c\/span\u003e\u003cspan\u003e¬†and¬†\u003c\/span\u003e\u003cspan\u003ethe controller is already running on¬†lower versions (4.4, 4.6¬†or 4.7) the first step you will need\u003c\/span\u003e\u003cspan\u003e¬†to do is¬†\u003c\/span\u003e\u003cspan\u003eto clean the controller¬†by installing the CleanDist file using the Distribution¬†\u003c\/span\u003e\u003cspan\u003eF\u003c\/span\u003e\u003cspan\u003eile¬†\u003c\/span\u003e\u003cspan\u003eI\u003c\/span\u003e\u003cspan\u003enstaller from the controller's platform and after that commission the MAC36NL controller with the 4.8.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat¬†are the¬†improvements for the MAC36NL¬†with¬†Niagara 4.6 and 4.7?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eWith the release of N4.6 and N4.7 for the MAC36NL you some new features:\u003c\/span\u003e\u003c\/p\u003e\n¬†- BACnet MSTP¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† -¬†HDMI\u003cbr\u003e¬†-¬†Data Recovery Service¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬†-¬†¬†\u003cspan\u003eWeb Service Port Fix\u003c\/span\u003e\u003cbr\u003ePlease see read the \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Release_Note\/iSMA-B-MAC36NL_Release_Notes.pdf\"\u003eRelease Notes\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\n\u003cspan style=\"color: #ff0000;\"\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row row-1\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat are the default platform Credentials?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe default credentials are the same as to the Tridium controllers:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003eUser: tridium\u003c\/p\u003e\n\u003cp\u003ePassword:niagara\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat communication networks are available?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eIn this stage the Networks that work are:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e- Modbus RS485\u003c\/p\u003e\n\u003cp\u003e- Modbus TCP\u003c\/p\u003e\n\u003cp\u003e- BACnet TCP\u003c\/p\u003e\n\u003cp\u003e- BACnet MSTP available for version N4.6 and N4.7.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e-¬†Mbus TCP\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e- Niagara Network\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat features are implemented into this controller compared to the Tridium Jace?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe iSMA has the same features as a Tridium N4 controller:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e-Alarm\u003c\/p\u003e\n\u003cp\u003e-Histories\u003c\/p\u003e\n\u003cp\u003e-PX pages (web User Interface pages) HTML 5 web viewing\u003c\/p\u003e\n\u003cp\u003e-Communication with Niagara controllers and Supervisors through Niagara Network¬†\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhen commissioning I see this message: there is no Core software found that can be installed, what should I do?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe core software is installed from the factoryfor version 4.4.73, you just need to press Next.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eAfter using the commissioning wizard to install the Station and modules, I can see into the Application Directory that there are errors regarding the Web Server and I cannot access the controller from the webpage. How do I resolve that error and access the controller through the web page?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eAt this stage the Web server works with the TCP port above 1024, so you will need to go and change the HTTP and HTTPs ports to be above 1024 (ex: HTTP port - 8080, HTTPs port 8443).\u003cspan\u003e¬†After setting this up please restart the station. \u003cstrong\u003eThis issue was resolved in N4.6 and N4.7 release.\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow does the Local IOs work?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe Local IO driver it is still at an early stage and you will need to Download the¬†\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/iSMAIO.zip\" style=\"color: #0000ff; text-decoration: underline;\"\u003eJar file.\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e¬†Put it into the Modules folder and restart the Workbench. Go and find the iSMA IO into the Palette.\u003c\/div\u003e\n\u003cdiv class=\"qs-content\"\u003eInto the Drivers add from the iSMA_IO Palette the iSMA IO Network, after that open the Property Sheet of the Drivers to see the recently added Network. Under it add the Local IO Device and under that add the points from the palette.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow do I change the Universal Input type?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eOpen the property sheet of the UI and you will see the Input type property, by default it is set to Voltage.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow do I change the Analog Output type?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eOpen the property sheet of the AO and you will see the Output type property, by default it is set to Voltage.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow can I use the HDMI function?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003e\n\u003cdiv class=\"qs-content\"\u003eAfter you have commissioned the controller on your N4.6 or N4.7¬† and install the iSMA_HDMI jar file, copy the HDMI service from the iSMA_HDMI pallette to the Service folder and you will need to go to the WEB service and activate the HTTP port and disable HTTPS Only. After you make those settings please reboot the controller.¬†\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e¬†Do you have a question about this product?\u003c\/strong\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\" target=\"_blank\" title=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-RS-150\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" alt=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-RS-150‚Äù style=\"\u003e\u003c\/a\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\" title=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-RS-150\"\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"gtx-trans\" style=\"position: absolute; left: 143px; top: 572.969px;\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321786228891,"sku":"iSMA-B-MAC36NL-RS;iSMA-B-SD-NL","price":2120.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-B-MAC36-RS-600x600_32c8c439-4b0d-4133-ac20-09d8ec0d0295.png?v=1737467137"},{"product_id":"isma-b-mac36nl-rs-100","title":"iSMA-B-MAC36NL-RS-100","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eThe iSMA-B-MAC36NL is Niagara controller with 36 onboard IO and license of 100 points and¬†two RS485 port. If more points are needed then you can upgrade in 50 points increment.\u003c\/p\u003e\n\u003cp\u003eThe MAC (Master Application Controller) with built-in different types of I\/O and operating in the Niagara Framework environment. Using the specific local I\/O set 16x UI, 8x AO, 4xDI and 8x DO allow to use the device in different applications. The controller provides control, data logging, alarming, scheduling, integration and visualisation.\u003c\/p\u003e\n\u003cp\u003eTo allow IP connectivity there are 2x Fast Ethernet ports which can operate as two independent ports. Built-in 2x RS485 can be used to expand number of I\/O by connecting MINI or MIX series I\/O modules or to integrate with other subsystems.\u003cbr\u003eiSMA-B-MAC36NL provides rich graphical interface displaying on a standard Web browser or on external display connected to built-in HDMI and USB port (touch-screen support).\u003cbr\u003e\u003cspan\u003eThere are two more hardware versions of the controller available: standard¬†\u003c\/span\u003e\u003cstrong\u003eiSMA-B-MAC36NL\u003c\/strong\u003e\u003cspan\u003e¬†and with¬†\u003c\/span\u003e\u003cstrong\u003eM-Bus interface\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003eThe Niagara versions available for this controller in the latest\u003cspan\u003e¬†\u003c\/span\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/\"\u003eInstaller\u003c\/a\u003e\u003cspan\u003e¬†\u003c\/span\u003eversion:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNiagara 4.4.73 (not recommended)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.4.92 (not recommended)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.6.96.28 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.7.109.20 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.8.0.110 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.9.0.198 (Use the installer v1.4)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.9.1.30 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.0.154 (Use the installer v1.5)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.1.36 (Use the installer v1.7)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.3.20  (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.11.1.16 (Use the installer v1.9)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.12.0.156 (Use the installer v1.8)\u003c\/li\u003e\n\u003cli\u003eNiagara 4.12.2.16 (Use the installer v1.9)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.7.42.1\u003c\/li\u003e\n\u003cli\u003eNiagara 4.10.9.14.1\u003c\/li\u003e\n\u003cli\u003eNiagara 4.13.2.18\u003c\/li\u003e\n\u003cli\u003eNiagara 4.14.0.162\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBACnet MSTP, Data Recovery Service, Web Service Ports fix and HDMI function are now available for N4.6 and higher.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eFor all new features and improvements, please see the¬†\u003c\/span\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Release_Note\/iSMA-B-MAC36NL_Release_Notes.pdf\" target=\"_blank\"\u003eRelease Notes\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMain features\u003cbr\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv style=\"text-align: justify;\" class=\"col-sm-6\"\u003e\n\u003cstrong\u003e16x Universal Inputs (16UI)\u003c\/strong\u003e\n\u003cp\u003eAll Universal Inputs have 16-bit ADC which support the following types of inputs:\u003cbr\u003eTemperature input supports the following types of sensors:\u003cbr\u003e10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1, Pt1000, Ni1000\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFor sensors Pt1000 and Ni1000 use only 16-bit resolution!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage input 0-10 V DC: input resistance 100 kŒ© accuracy ¬±0,1%, measurement resolution 3 mV @ 12-bit\u003cbr\u003eand 1 mV @ 16-bit\u003c\/li\u003e\n\u003cli\u003eCurrent input 0-20 mA (external resistor¬†200 Œ© required)\u003c\/li\u003e\n\u003cli\u003eResistive input 0-1000 kŒ©: measurement resolution\u003cbr\u003efor 20 kŒ© load: 20 Œ© @ 12-bit and 1 Œ© @ 16-bit\u003c\/li\u003e\n\u003cli\u003eDry contact input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e4x Digital Inputs (4DI)\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eDry contact inputs\u003c\/li\u003e\n\u003cli\u003eFast pulse counter up to 100 Hz saved in SD Card\u003c\/li\u003e\n\u003c\/ul\u003e\n8x Analog Outputs (8AO)\n\u003cp\u003eAll Analog Outputs are equipped with 12-bit ADC provides 10 mV resolution and accuracy less than ¬±0,5%. They support the following output types:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage: 0-10 V DC max. load up to 20 mA\u003c\/li\u003e\n\u003cli\u003ePWM: 0,01 Hz, 0,1 Hz, 1 Hz, 10 Hz, 100 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e8x Digital Outputs (8DO) \u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eRelay output (NO): max. 3 A @ 30 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-6\"\u003e\n\u003cstrong\u003ePlatform\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eMulticore Cortex-A Series ARM Processor\u003c\/li\u003e\n\u003cli\u003e1GB DDR3 SDRAM\u003c\/li\u003e\n\u003cli\u003eRemovable micro-SD card ‚Äì 4 GB\u003cbr\u003e(2 GB system reserved \/ 2 GB user storage)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eCommunication \u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003eRS485 half-duplex, opto-isolated\u003c\/li\u003e\n\u003cli\u003eBaud rate from 2400 to 115200\u003c\/li\u003e\n\u003cli\u003e2x Fast Ethernet (independent)\u003c\/li\u003e\n\u003cli\u003e2x USB (1x OTG, 1x Host)\u003c\/li\u003e\n\u003cli\u003eHDMI type A (standard)\u003c\/li\u003e\n\u003cli\u003eMicro SD card slot\u003c\/li\u003e\n\u003cli\u003eModbus RTU\/ASCII\/IP, BACnet MSTP\/IP, oBIX, SNMP,\u003cbr\u003eLON\/IP, KNX\/IP\u003c\/li\u003e\n\u003cli\u003eSecond RS485\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003ePower supply \u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003e24 V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eHousing\u003c\/strong\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003eDimensions: 160x110x62 mm.\u003c\/li\u003e\n\u003cli\u003eConstruction: UL approved,\u003cbr\u003eself-extinguishing plastic (PC\/ABS)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting DIN (DIN EN 50022 norm)\u003c\/li\u003e\n\u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: justify;\"\u003eOperating temperature: -10¬∞C to 50¬∞C\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eStorage temperature: -40¬∞C to 85¬∞C\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eRelative humidity: 5% to 95%, no condensation\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eIngress Protection Rating: IP40 ‚Äì for indoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\n\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/a\u003e¬†\u003c\/h5\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003cdiv\u003e\n\u003ch4\u003eProduct Informations\u003c\/h4\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat is the default IP of the device?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe default IP is : 192.168.1.123.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat Niagara version is needed to connect to this controller?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eAt the moment the¬†default Niagara version is N4.4 (4.4.73.24).\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat should I do if I need to use Niagara 4.4.92.2?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eTo install dist you can either copy the \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/Precious%20Versions\/iSMA-MAC36_nre_4.4.92.2\/\"\u003eDIST FILES\u003c\/a\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/iSMA-MAC36_nre_4.4.92.2\/\"\u003e \u003c\/a\u003eto your¬†\u003cbr\u003e%HOMEPATH%\\Niagara4.4\\sw\\inbox folder and use commisioning wizard, or use Platform‚ÜíDistribution File Installer, choose file and install.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat should I do if I need to use Niagara 4.6, 4.7 or 4.8?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e¬†Please download the¬†latest update files¬†\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eHERE\u003c\/span\u003e\u003c\/a\u003e, into the zipfile, which contains the DIST files for version 4.6, 4.7 and 4.8. You will find a file named ‚ÄúiSMA_MAC36_files_installer_v1.0.1152.bat‚Äù, this will copy for you all the DIST files into the relevant folders. After this procedure you will need to restart the Workplace and commission your MAC36NL with the 4.6, 4.7 or 4.8 version.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf you need to upgrade to 4.8\u003c\/span\u003e\u003cspan\u003e¬†and¬†\u003c\/span\u003e\u003cspan\u003ethe controller is already running on¬†lower versions (4.4, 4.6¬†or 4.7) the first step you will need\u003c\/span\u003e\u003cspan\u003e¬†to do is¬†\u003c\/span\u003e\u003cspan\u003eto clean the controller¬†by installing the CleanDist file using the Distribution¬†\u003c\/span\u003e\u003cspan\u003eF\u003c\/span\u003e\u003cspan\u003eile¬†\u003c\/span\u003e\u003cspan\u003eI\u003c\/span\u003e\u003cspan\u003enstaller from the controller's platform and after that commission the MAC36NL controller with the 4.8.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat¬†are the¬†improvements for the MAC36NL¬†with¬†Niagara 4.6 and 4.7?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eWith the release of N4.6 and N4.7 for the MAC36NL you some new features:\u003c\/span\u003e\u003c\/p\u003e\n¬†- BACnet MSTP¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† -¬†HDMI\u003cbr\u003e¬†-¬†Data Recovery Service¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬† ¬†-¬†¬†\u003cspan\u003eWeb Service Port Fix\u003c\/span\u003e\u003cbr\u003ePlease see read the \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Release_Note\/iSMA-B-MAC36NL_Release_Notes.pdf\"\u003eRelease Notes\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\n\u003cspan style=\"color: #ff0000;\"\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row row-1\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat are the default platform Credentials?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe default credentials are the same as to the Tridium controllers:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003eUser: tridium\u003c\/p\u003e\n\u003cp\u003ePassword:niagara\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat communication networks are available?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eIn this stage the Networks that work are:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e- Modbus RS485\u003c\/p\u003e\n\u003cp\u003e- Modbus TCP\u003c\/p\u003e\n\u003cp\u003e- BACnet TCP\u003c\/p\u003e\n\u003cp\u003e- BACnet MSTP available for version N4.6 and N4.7.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e-¬†Mbus TCP\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e- Niagara Network\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhat features are implemented into this controller compared to the Tridium Jace?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe iSMA has the same features as a Tridium N4 controller:\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e-Alarm\u003c\/p\u003e\n\u003cp\u003e-Histories\u003c\/p\u003e\n\u003cp\u003e-PX pages (web User Interface pages) HTML 5 web viewing\u003c\/p\u003e\n\u003cp\u003e-Communication with Niagara controllers and Supervisors through Niagara Network\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eWhen commissioning I see this message: there is no Core software found that can be installed, what should I do?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe core software is installed from the factoryfor version 4.4.73, you just need to press Next.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eAfter using the commissioning wizard to install the Station and modules, I can see into the Application Directory that there are errors regarding the Web Server and I cannot access the controller from the webpage. How do I resolve that error and access the controller through the web page?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eAt this stage the Web server works with the TCP port above 1024, so you will need to go and change the HTTP and HTTPs ports to be above 1024 (ex: HTTP port - 8080, HTTPs port 8443).\u003cspan\u003e¬†After setting this up please restart the station. \u003cstrong\u003eThis issue was resolved in N4.6 and N4.7 release.\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow does the Local IOs work?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eThe Local IO driver it is still at an early stage and you will need to Download the¬†\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca style=\"color: #0000ff; text-decoration: underline;\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\/Niagara\/iSMAIO.zip\"\u003eJar file.\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e¬†Put it into the Modules folder and restart the Workbench. Go and find the iSMA IO into the Palette.\u003c\/div\u003e\n\u003cdiv class=\"qs-content\"\u003eInto the Drivers add from the iSMA_IO Palette the iSMA IO Network, after that open the Property Sheet of the Drivers to see the recently added Network. Under it add the Local IO Device and under that add the points from the palette.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow do I change the Universal Input type?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eOpen the property sheet of the UI and you will see the Input type property, by default it is set to Voltage.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow do I change the Analog Output type?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003eOpen the property sheet of the AO and you will see the Output type property, by default it is set to Voltage.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-1\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch4\u003e\u003cspan style=\"color: #ff0000;\"\u003eHow can I use the HDMI function?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qs-content\"\u003e\n\u003cdiv class=\"qs-content\"\u003eAfter you have commissioned the controller on your N4.6 or N4.7¬† and install the iSMA_HDMI jar file, copy the HDMI service from the iSMA_HDMI pallette to the Service folder and you will need to go to the WEB service and activate the HTTP port and disable HTTPS Only. After you make those settings please reboot the controller.¬†\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e¬†\u003cbr\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36\" target=\"_blank\" title=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-RS-100\" rel=\"noopener\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-RS-100‚Äù style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-MAC36NL-RS-100\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MAC36NL\"\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"position: absolute; left: 146px; top: 572.969px;\" id=\"gtx-trans\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321789833371,"sku":"iSMA-B-MAC36NL-RS;iSMA-B-SD-NL","price":1884.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-B-MAC36-RS-600x600.png?v=1737467136"},{"product_id":"isma-b-rj12-5","title":"iSMA-B-RJ12-5","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eMounting accessory for ISMA-B-FCU, ISMA-B-2D1B, ISMA-B-2D - plastic cover for terminals, recommended for the controllers powered with 230 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e \u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003c\/strong\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321831579803,"sku":"iSMA-B-RJ12-5","price":11.0,"currency_code":"EUR","in_stock":true}]},{"product_id":"isma-b-cvt-rs485","title":"iSMA-B-CVT-RS485","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\nbr {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003cp\u003e\u003cspan data-sheets-value='{\"1\":2,\"2\":\"USB to RS485 Converter, USB 1.0 and 2.0 compatibile, built-in: status LEDs, switchable terminating resistor, EEPROM memory. Communication over 3-wire bus.  The miniUSB to USB cable is not included. \"}' data-sheets-userformat='{\"2\":33567228,\"5\":{\"1\":[{\"1\":2,\"2\":0,\"5\":[null,2,13421772]},{\"1\":0,\"2\":0,\"3\":3},{\"1\":1,\"2\":0,\"4\":1}]},\"6\":{\"1\":[{\"1\":2,\"2\":0,\"5\":[null,2,13421772]},{\"1\":0,\"2\":0,\"3\":3},{\"1\":1,\"2\":0,\"4\":1}]},\"7\":{\"1\":[{\"1\":2,\"2\":0,\"5\":[null,2,13421772]},{\"1\":0,\"2\":0,\"3\":3},{\"1\":1,\"2\":0,\"4\":1}]},\"8\":{\"1\":[{\"1\":2,\"2\":0,\"5\":[null,2,13421772]},{\"1\":0,\"2\":0,\"3\":3},{\"1\":1,\"2\":0,\"4\":1}]},\"9\":0,\"10\":1,\"11\":4,\"15\":\"Trebuchet MS\",\"16\":10,\"28\":1}'\u003eUSB to RS485 Converter, USB 1.0 and 2.0 compatibile, built-in: status LEDs, switchable terminating resistor, EEPROM memory. Communication over 3-wire bus. The miniUSB to USB cable is not included. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-CVT-RS485\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-CVT-RS485\/Datasheet\/iSMA-B-CVT-RS_485_Datasheet.pdf\/\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-CVT-RS485‚Äù style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-CVT-RS485\" href=\"http:\/\/support.innon.com\/SFAR\/SFAR-1M\/%E2%80%9D%20title=\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321832038555,"sku":"iSMA-B-CVT-RS485","price":86.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/isma-b-CVT-RS485.png?v=1737467117"},{"product_id":"isma-b-rj12-15","title":"iSMA-B-RJ12-15","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eMounting accessory for ISMA-B-FCU, ISMA-B-2D1B, ISMA-B-2D, iSMA-B-LP. RJ 12 cable - 10 meters long.\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321832104091,"sku":"iSMA-B-RJ12-15","price":13.0,"currency_code":"EUR","in_stock":true}]},{"product_id":"isma-b-rj12-10","title":"iSMA-B-RJ12-10","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eMounting accessory for ISMA-B-FCU, ISMA-B-2D1B, ISMA-B-2D, iSMA-B-LP. RJ 12 cable - 5 meters long.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321832169627,"sku":"iSMA-B-RJ12-10","price":12.0,"currency_code":"EUR","in_stock":true}]},{"product_id":"isma-b-tc-7s","title":"iSMA-B-TC-7S","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eMounting accessory - plastic cover for terminals, recomended for the FCU controllers powered with 230V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321832235163,"sku":"iSMA-B-TC-7S","price":12.0,"currency_code":"EUR","in_stock":true}]},{"product_id":"isma-b-fcu-hl-tb-1","title":"iSMA-B-FCU-HL-TB","description":"\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003cp\u003e\u003cspan data-sheets-value='{\"1\":2,\"2\":\"Accessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-FCU-HH \/ iSMA-B-FCU-HL controllers.\"}' data-sheets-userformat='{\"2\":391747,\"3\":[null,2,\"General\",0],\"4\":[null,2,16777215],\"9\":0,\"12\":0,\"14\":[null,2,0],\"15\":\"arial,sans,sans-serif\",\"16\":10,\"17\":0,\"18\":0,\"19\":0,\"21\":0}'\u003eAccessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-FCU-HH \/ iSMA-B-FCU-HL controllers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321832661147,"sku":"iSMA-B-FCU-HL-TB","price":26.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/iSMA-B-FCU-HH-TB_iSMA-B-FCU-HL-TB_iSMA-B-FCU-LL-TB_1024x1024_ed0c418e-8c84-42de-a3fa-b3f5e27b5722.jpg?v=1737467114"},{"product_id":"isma-b-4u4o-tb","title":"iSMA-B-4U4O-TB","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eAccessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-4U4O-H \/ iSMA-B-4U4O-H-IP module types. Accessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-4U4O-H \/ iSMA-B-4U4O-H-IP module types.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MIX\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-4U4O-TB\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" alt=\"Documentation \u0026amp; Downloads for iSMA-B-4U4O-TB‚Äù style=\" float:=\"\" none=\"\"\u003e\u003c\/a\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MIX\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-4U4O-TB\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321832693915,"sku":"iSMA-B-4U4O-TB","price":12.0,"currency_code":"EUR","in_stock":true}]},{"product_id":"isma-b-fcu-hl-tb","title":"iSMA-B-FCU-LL-TB","description":"\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003eAccessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-FCU-LL controllers.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \n","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321855860891,"sku":"iSMA-B-FCU-LL-TB","price":26.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/iSMA-B-FCU-HH-TB_iSMA-B-FCU-HL-TB_iSMA-B-FCU-LL-TB_0a7e8303-db3c-4663-a5d4-ede43aed70d4.jpg?v=1737467109"},{"product_id":"isma-b-fcu-hh-tb","title":"iSMA-B-FCU-HH-TB","description":"\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003eAccessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-FCU-HH controllers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321856155803,"sku":"iSMA-B-FCU-HH-TB","price":26.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/iSMA-B-FCU-HH-TB_iSMA-B-FCU-HL-TB_iSMA-B-FCU-LL-TB.jpg?v=1737467108"},{"product_id":"isma-b-aac20-m-tb","title":"iSMA-B-AAC20-M-TB","description":"\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003eAccessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-AAC20-M \/ iSMA-B-AAC20-LCD-M controllers.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \n\n\n\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-AAC20\/\" target=\"_blank\" title=\"Documentation \u0026amp; Downloads for iSMA-B-AAC20-M-TB\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-AAC20-M-TB style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-AAC20-M-TB\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-AAC20\/\"\u003e \u003c\/a\u003e\n","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321857040539,"sku":"iSMA-B-AAC20-M-TB","price":23.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/iSMA-B-AAC20-M-TB.png?v=1737467108"},{"product_id":"isma-b-aac20-d-tb","title":"iSMA-B-AAC20-D-TB","description":"\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003eAccessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-AAC20-D \/ iSMA-B-AAC20-LCD-D controllers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-AAC20\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-AAC20-D-TB\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-AAC20-D-TB style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-AAC20-D-TB\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-AAC20\/\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321857892507,"sku":"iSMA-B-AAC20-D-TB","price":23.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/iSMA-B-AAC20-D-TB.png?v=1737467107"},{"product_id":"isma-b-aac20-tb","title":"iSMA-B-AAC20-TB","description":"\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003eAccessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-AAC20 \/ iSMA-B-AAC20-LCD controllers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-AAC20\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-AAC20-TB\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-AAC20-TB style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-AAC20-TB\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-AAC20\/\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321858056347,"sku":"iSMA-B-AAC20-TB","price":21.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/iSMA-B-AAC20-TB.png?v=1737467106"},{"product_id":"isma-b-mg-ip-tb","title":"iSMA-B-MG-IP-TB","description":"\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003eAccessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-MG-IP gateway.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321859203227,"sku":"iSMA-B-MG-IP-TB","price":12.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/iSMA-B-MG-IP-TB.png?v=1737467106"},{"product_id":"isma-b-mix38-tb","title":"iSMA-B-MIX38-TB","description":"\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003eAccessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-MIX38 \/ iSMA-B-MIX38-IP module types.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MIX\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-MIX38-TB\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" alt=\"Documentation \u0026amp; Downloads for iSMA-B-MIX38-TB‚Äù style=\" float:=\"\" none=\"\"\u003e\u003c\/a\u003e\u003ca href=\"http:\/\/support.innon.com\/SFAR\/SFAR-1M\/%E2%80%9D%20title=\" title=\"Documentation \u0026amp; Downloads for iSMA-B-MIX38-TB\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321859825819,"sku":"iSMA-B-MIX38-TB","price":33.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/iSMA-B-MIX38-TB.png?v=1737467105"},{"product_id":"isma-b-mix18-tb","title":"iSMA-B-MIX18-TB","description":"\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003eAccessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-MIX18 \/ iSMA-B-MIX18-IP module types.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-MIX18-TB\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MIX\/\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-MIX18-TB‚Äù style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-MIX18-TB\" href=\"http:\/\/support.innon.com\/SFAR\/SFAR-1M\/%E2%80%9D%20title=\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321860972699,"sku":"iSMA-B-MIX18-TB","price":19.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/iSMA-B-MIX18-TB.png?v=1737467105"},{"product_id":"isma-b-4to-tb","title":"iSMA-B-4TO-TB","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003eAccessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-4TO-H \/ iSMA-B-4TO-H-IP module types.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MIX\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-4TO-TB\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" alt=\"Documentation \u0026amp; Downloads for iSMA-B-4TO-TB‚Äù style=\" float:=\"\" none=\"\"\u003e\u003c\/a\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MIX\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-4TO-TB\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321861824667,"sku":"iSMA-B-4TO-TB","price":12.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-B-4TO-TB.png?v=1737467104"},{"product_id":"isma-b-4o-tb","title":"iSMA-B-4O-TB","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003eAccessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-4O-H \/ iSMA-B-4O-H-IP module types.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MIX\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-4O-TB\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" alt=\"Documentation \u0026amp; Downloads for iSMA-B-4O-TB‚Äù style=\" float:=\"\" none=\"\"\u003e\u003c\/a\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MIX\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-4O-TB\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321863102619,"sku":"iSMA-B-4O-TB","price":12.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/isma-B-4O-TB.png?v=1737467103"},{"product_id":"isma-b-4u4a-tb","title":"iSMA-B-4U4A-TB","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eAccessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-4U4A-H \/ iSMA-B-4U4A-H-IP module types.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MIX\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-4U4A-TB\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" alt=\"Documentation \u0026amp; Downloads for iSMA-B-4U4A-TB‚Äù style=\" float:=\"\" none=\"\"\u003e\u003c\/a\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MIX\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-4U4A-TB\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321863790747,"sku":"iSMA-B-4U4A-TB","price":12.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-B-4U4A-TB.png?v=1737467103"},{"product_id":"isma-b-4i4o-tb","title":"iSMA-B-4I4O-TB","description":"\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003eAccessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-4I4O-H \/ iSMA-B-4I4O-H-IP module types.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e¬†Do you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MIX\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-4I4O-TB\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" alt=\"Documentation \u0026amp; Downloads for iSMA-B-4I4O-TB‚Äù style=\" float:=\"\" none=\"\"\u003e\u003c\/a\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MIX\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-4I4O-TB\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321865232539,"sku":"iSMA-B-4I4O-TB","price":12.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-B-4I4O-TB.png?v=1737467102"},{"product_id":"isma-b-8u-tb","title":"iSMA-B-8U-TB","description":"\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003eAccessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: ISMA-B-8U \/ iSMA-B-8U-IP module types.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MIX\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-8U-TB\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" alt=\"Documentation \u0026amp; Downloads for iSMA-B-8U-TB‚Äù style=\" float:=\"\" none=\"\"\u003e\u003c\/a\u003e\u003ca href=\"http:\/\/support.innon.com\/SFAR\/SFAR-1M\/%E2%80%9D%20title=\" title=\"Documentation \u0026amp; Downloads for iSMA-B-8U-TB\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321866313883,"sku":"iSMA-B-8U-TB","price":12.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/iSMA-B-8I-TB.png?v=1737467101"},{"product_id":"isma-b-8i-tb","title":"iSMA-B-8I-TB","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAccessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-8I \/ ISMA-B-8I-IP module types.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MIX\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-8I-TB\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" alt=\"Documentation \u0026amp; Downloads for iSMA-B-8I-TB‚Äù style=\"\u003e\u003c\/a\u003e\u003ca href=\"http:\/\/support.innon.com\/SFAR\/SFAR-1M\/%E2%80%9D%20title=\" title=\"Documentation \u0026amp; Downloads for iSMA-B-8I-TB\"\u003e \u003c\/a\u003e\u003c\/p\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321866412187,"sku":"iSMA-B-8I-TB","price":12.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/iSMA-B-8I-TB_9f068ad1-cac6-429f-971e-d6506472b734.png?v=1737467101"},{"product_id":"isma-b-lp-hc-1","title":"iSMA-B-LP-HC-1","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eiSMA-B-HC-1\u003c\/strong\u003e¬†is a room unit with \u003cstrong\u003e2.3‚Äù LCD\u003c\/strong\u003e display and four function buttons. Additionally, the room unit has the built-in temperature sensor and the humidity and CO\u003csub\u003e2\u003c\/sub\u003esensors.\u003c\/p\u003e\n\u003cp\u003eiSMA-B-LP-HC-1 is powered with 24 V AC\/DC and has the built-in ¬†RS485 port (\u003cstrong\u003eModbus RTU\/ASCII\u003c\/strong\u003e). Use of open communication protocol allows to connect the room unit with any controller supports Modbus RTU\/ASCII. Together with \u003ca href=\"https:\/\/www.innon.co.uk\/search?type=product\u0026amp;q=isma-b-fcu\" title=\"iSMA-B-FCU controllers\"\u003eiSMA-B-FCU \u003c\/a\u003econtroller, the room unit allows to change the basic parameters such as: temperature setpoint, fan speed, FCU mode and others.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThanks to built-in USB port, there is possibility to firmware update and room unit configuration without the necessity of power supply. iSMA-B-LP-HC-1 has the modern design and is available in different colours (white is basic) on client request.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-LP\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-LP-HC-1\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-LP-HC-1 style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-LP-HC-1\" href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-LP\/\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321866739867,"sku":"iSMA-B-LP-HC-1","price":514.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/iSMA-B-LP.png?v=1737467100"},{"product_id":"isma-b-lp-h-1","title":"iSMA-B-LP-H-1","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eiSMA-B-LP-H-1\u003c\/strong\u003e is a room unit with \u003cstrong\u003e2.3‚Äù LCD\u003c\/strong\u003e display and four function buttons. Additionally, the room unit has the built-in temperature sensor and the humidity¬†sensor.\u003c\/p\u003e\n\u003cp\u003eiSMA-B-LP-H-1 is powered with 24 V AC\/DC and has the built-in ¬†RS485 port (\u003cstrong\u003eModbus RTU\/ASCII\u003c\/strong\u003e). Use of open communication protocol allows to connect the room unit with any controller supports Modbus RTU\/ASCII. Together with \u003ca href=\"https:\/\/www.innon.co.uk\/search?type=product\u0026amp;q=isma-b-fcu\" title=\"iSMA-B-FCU controllers\"\u003eiSMA-B-FCU \u003c\/a\u003econtroller, the room unit allows to change the basic parameters such as: temperature setpoint, fan speed, FCU mode and others.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThanks to built-in USB port, there is possibility to firmware update and room unit configuration without the necessity of power supply. iSMA-B-LP-H-1 has the modern design and is available in different colours (white is basic) on client request.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-LP\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-LP-H-1\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-LP-H-1 style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-LP-H-1\" href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-LP\/\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321868607643,"sku":"iSMA-B-LP-H-1","price":208.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/LP-1_persp_72a74333-13bc-4896-aa92-48875ff102be.png?v=1737467099"},{"product_id":"isma-b-lp-c-1","title":"iSMA-B-LP-C-1","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eiSMA-B-LP-C-1\u003c\/strong\u003e is a room unit with \u003cstrong\u003e2.3‚Äù LCD\u003c\/strong\u003e display and four function buttons. Additionally, the room unit has the built-in temperature sensor CO\u003csub\u003e2\u003c\/sub\u003esensors.\u003c\/p\u003e\n\u003cp\u003eiSMA-B-LP-C-1 is powered with 24 V AC\/DC and has the built-in ¬†RS485 port (\u003cstrong\u003eModbus RTU\/ASCII\u003c\/strong\u003e). Use of open communication protocol allows to connect the room unit with any controller supports Modbus RTU\/ASCII. Together with \u003ca href=\"https:\/\/www.innon.co.uk\/search?type=product\u0026amp;q=isma-b-fcu\" title=\"iSMA-B-FCU controllers\"\u003eiSMA-B-FCU \u003c\/a\u003econtroller, the room unit allows to change the basic parameters such as: temperature setpoint, fan speed, FCU mode and others.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThanks to built-in USB port, there is possibility to firmware update and room unit configuration without the necessity of power supply. iSMA-B-LP-C-1 has the modern design and is available in different colours (white is basic) on client request.\u003c\/span\u003e\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-LP\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-LP-C-1\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-LP-C-1 style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-LP-C-1\" href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-LP\/\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321870737563,"sku":"iSMA-B-LP-C-1","price":445.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/iSMA-B-LP_9206478d-3a28-468f-9fa4-7f2afdac953e.png?v=1737467099"}],"url":"https:\/\/www.innon.fr\/collections\/isma.oembed?page=6","provider":"Innon Europe","version":"1.0","type":"link"}