{"title":"BACnet","description":"","products":[{"product_id":"lnk-io20-ip-bac-bacnet-ip-io-module-with-20-i-o","title":"LNK-IO20-IP-BAC BACnet IP IO Module with 20 I\/O","description":"\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLink IO is an Open Protocol, distributed IO System with a 5-year warranty¬†designed to help our System Integrators access any project from small to large without compromising quality or flexibility.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eInnon produces Link IO in collaboration with¬†CAREL S.p.A\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e, an Italian controls manufacturer trusted all over the world in critical control applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe Link IO contains one main unit which can be either Modbus or both Modbus and Bacnet with either RS458 or IP connection.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe system contains one main unit that can be either Bacnet or Modbus and up to 10 expansion units.¬†\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis \u003cstrong\u003eLNK-IO20-IP-BAC¬†\u003c\/strong\u003e¬†is the main unit that comes with an¬†IP connection and both BACnet and Modbus protocol available.¬†\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis main unit has 20 I\/Os, and you can expand it with 160 I\/Os by using maximum 10 expansion units. So you get a total of 180 I\/O points for one main unit.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis main unit has an IP connection to the controller and is using an RS485 connection to the expansion units.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eTo configure this main unit and the expansion modules, you can either:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e1. Use our web configurator:\u003c\/span\u003e¬†\u003ca href=\"https:\/\/link.innon.com\" style=\"font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 1.4em;\" data-mce-style=\"font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 1.4em;\"\u003ehttps:\/\/link.innon.com\u003c\/a\u003e.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eOnce you have downloaded¬†your required configuration, you¬†can upload it to your main unit. The expansion modules will be automatically configured. You can¬†configure everything in one go.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e2. Use the display of the main unit.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAnother¬†new feature is the screen which allows you to check the status of points or turn things on and off directly via the screen. This is ideal in projects where you need to turn the¬†heating¬†on, for example, before even commissioning the BMS.\u003cbr\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eKey Features:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e10 Universal Inputs or Outputs\u003c\/li\u003e\n\u003cli\u003e6 x Digital outputs (DO)\u003c\/li\u003e\n\u003cli\u003e2 x Digital Inputs (DI)\u003c\/li\u003e\n\u003cli\u003e2 x Analogue Outputs (AO)\u003c\/li\u003e\n\u003cli\u003eExpandable up to 180 I\/O points (up to 10 Expansion Modules)\u003c\/li\u003e\n\u003cli\u003eCommissioning using the display\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Auto using the display\u003c\/li\u003e\n\u003cli\u003eWatchdog for safe operation\u003c\/li\u003e\n\u003cli\u003eBuilt-in stand-alone IO functions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003ca title=\"Documentation \u0026amp; Downloads for Link IO\" href=\"http:\/\/support.innon.com\/Link%20IO\/\" target=\"_blank\"\u003e\u003cimg style=\"float: none;\" alt=\"Documentation \u0026amp; Downloads for Link IO\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\"\u003e\u003c\/a\u003e\u003c\/div\u003e","brand":"Innon Energy LTD","offers":[{"title":"Default Title","offer_id":36883481460891,"sku":"LNK-IO20-IP","price":632.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/Link_IO_IP_BAC.png?v=1737467259"},{"product_id":"lnk-add-bac","title":"LNK-ADD-BAC","description":"\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLink IO is an Open Protocol, distributed IO System with a 5-year warranty¬†designed to help our System Integrators access any project from small to large without compromising quality or flexibility.¬†\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis \u003cstrong\u003eLNK-ADD-BAC¬†\u003c\/strong\u003e¬†is a software licence that can be added to the Link IO Modbus modules and enable them to also have BACnet protocol enabled.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eIf you want to upgrade one of your Link IO Modbus modules to be BACnet enabled to use this part number or email office@innon.co.uk.\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003ca href=\"http:\/\/support.innon.com\/Link%20IO\/\" title=\"Documentation \u0026amp; Downloads for Link IO\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" alt=\"Documentation \u0026amp; Downloads for Link IO\" style=\"float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e","brand":"Innon Energy LTD","offers":[{"title":"Default Title","offer_id":37321528279195,"sku":"LNK-ADD-BAC","price":181.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/LinkIO.png?v=1737467255"},{"product_id":"lnk-io-disp-link-io-display","title":"LNK-IO-DISP Link IO Display","description":"\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Link IO Display is an optional component for the \u003ca href=\"https:\/\/www.innon.com\/linkio\" target=\"_blank\"\u003eLink IO System\u003c\/a\u003e. It consists of an external panel mounted display replicating exactly the operation of the onboard display of \u003cmeta charset=\"utf-8\"\u003e\u003ca href=\"https:\/\/www.innon.com\/linkio\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/www.innon.com\/linkio\" target=\"_blank\"\u003eLink IO System\u003c\/a\u003e, with the same 6 buttons easily accessible on the sides (membrane keys). The Link IO Display is a versatile device that can be used both to ease the \u003cmeta charset=\"utf-8\"\u003e\u003ca href=\"https:\/\/www.innon.com\/linkio\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/www.innon.com\/linkio\" target=\"_blank\"\u003eLink IO System\u003c\/a\u003e install and commissioning process, or can be permanently installed on an electric panel, providing access to all the useful I\/O readings and AUTO\/MANUAL operation without having to open the panel door.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003ca href=\"http:\/\/support.innon.com\/Link%20IO\/\" title=\"Documentation \u0026amp; Downloads for Link IO\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" alt=\"Documentation \u0026amp; Downloads for Link IO\" style=\"float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e","brand":"Innon Energy LTD","offers":[{"title":"Default Title","offer_id":37321530278043,"sku":"LNK-IO-DISP","price":312.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/LinkDisplay.png?v=1737467255"},{"product_id":"lnk-io16-exp-expansion-io-module-with-16-i-o","title":"LNK-IO16-EXP Expansion IO Module with 16 I\/O","description":"\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLink IO is an Open Protocol, distributed IO System with a 5-year warranty¬†designed to help our System Integrators access any project from small to large without compromising quality or flexibility.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eInnon produces Link IO in collaboration with¬†CAREL S.p.A\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e, an Italian controls manufacturer trusted all over the world in critical control applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe Link IO contains one main unit which can be either Modbus or both Modbus and Bacnet with either RS458 or IP connection.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe system contains one main unit that can be either Bacnet or Modbus and up to 10 expansion units.¬†\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis \u003cstrong\u003eLNK-IO16-EXP¬†\u003c\/strong\u003e¬†is an expansion IO that connects to the main Link IO unit.¬†\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis¬†expansion unit has¬†16 I\/Os 10 Universal Inputs and Outputs¬†and 6 Digital Outputs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eYou can connect up to 10 Expansion IO units to the main unit.¬†\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eOnce you connect your expansion units to the main unit these will be automatically configured from the main unit.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eTo configure this main unit and the expansion modules, you can either:\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e1. Use our web configurator:\u003c\/span\u003e¬†\u003ca href=\"https:\/\/link.innon.com\" style=\"font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 1.4em;\" data-mce-style=\"font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 1.4em;\"\u003ehttps:\/\/link.innon.com\u003c\/a\u003e.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eOnce you have downloaded¬†your required configuration, you¬†can upload it to your main unit. The expansion modules will be automatically configured. You can¬†configure everything in one go.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e2. Use the display of the main unit.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAnother¬†new feature is the screen which allows you to check the status of points or turn things on and off directly via the screen. This is ideal in projects where you need to turn the¬†heating¬†on, for example, before even commissioning the BMS.\u003cbr\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eKey Features:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e10 Universal Inputs or Outputs\u003c\/li\u003e\n\u003cli\u003e6 x Digital outputs (DO)\u003c\/li\u003e\n\u003cli\u003eWatchdog for safe operation\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt-in stand-alone IO functions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003ca href=\"http:\/\/support.innon.com\/Link%20IO\/\" title=\"Documentation \u0026amp; Downloads for Link IO\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" alt=\"Documentation \u0026amp; Downloads for Link IO\" style=\"float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e","brand":"Innon Energy LTD","offers":[{"title":"Default Title","offer_id":37321530671259,"sku":"LNK-IO16-EXP","price":286.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/LNK-IO16-EXP.png?v=1737467254"},{"product_id":"lnk-io20-rs-bac-bacnet-rs485-io-module-with-20-i-o","title":"LNK-IO20-RS-BAC BACnet RS485 IO Module with 20 I\/O","description":"\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLink IO is an Open Protocol, distributed IO System with a 5-year warranty¬†designed to help our System Integrators access any project from small to large without compromising quality or flexibility.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eInnon produces Link IO in collaboration with¬†CAREL S.p.A\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e, an Italian controls manufacturer trusted all over the world in critical control applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe Link IO contains one main unit which can be either Modbus or both Modbus and Bacnet with either RS458 or IP connection.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe system contains one main unit that can be either Bacnet or Modbus and up to 10 expansion units.¬†\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis \u003cstrong\u003eLNK-IO20-RS-BAC¬†\u003c\/strong\u003e¬†is the main unit that comes with an¬†RS485 connection and both BACnet and Modbus protocol available.¬†\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis main unit has 20 I\/Os, and you can expand it with 160 I\/Os by using maximum 10 expansion units. So you get a total of 180 I\/O points for one main unit.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eThis main unit has an IP connection to the controller and is using an RS485 connection to the expansion units.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eTo configure this main unit and the expansion modules, you can either:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003e1. Use our web configurator:\u003c\/span\u003e¬†\u003ca href=\"https:\/\/link.innon.com\" style=\"font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 1.4em;\" data-mce-style=\"font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 1.4em;\"\u003ehttps:\/\/link.innon.com\u003c\/a\u003e.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eOnce you have downloaded¬†your required configuration, you¬†can upload it to your main unit. The expansion modules will be automatically configured. You can¬†configure everything in one go.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e2. Use the display of the main unit.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAnother¬†new feature is the screen which allows you to check the status of points or turn things on and off directly via the screen. This is ideal in projects where you need to turn the¬†heating¬†on, for example, before even commissioning the BMS.\u003cbr\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eKey Features:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e10 Universal Inputs or Outputs\u003c\/li\u003e\n\u003cli\u003e6 x Digital outputs (DO)\u003c\/li\u003e\n\u003cli\u003e2 x Digital Inputs (DI)\u003c\/li\u003e\n\u003cli\u003e2 x Analogue Outputs (AO)\u003c\/li\u003e\n\u003cli\u003eExpandable up to 180 I\/O points (up to 10 Expansion Modules)\u003c\/li\u003e\n\u003cli\u003eCommissioning using the display\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Auto using the display\u003c\/li\u003e\n\u003cli\u003eWatchdog for safe operation\u003c\/li\u003e\n\u003cli\u003eBuilt-in stand-alone IO functions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003ca href=\"http:\/\/support.innon.com\/Link%20IO\/\" title=\"Documentation \u0026amp; Downloads for Link IO\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" alt=\"Documentation \u0026amp; Downloads for Link IO\" style=\"float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e","brand":"Innon Energy LTD","offers":[{"title":"Default Title","offer_id":37321533489307,"sku":"LNK-IO20-RS","price":507.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/LinkIO_f4daef37-54a4-4a4a-aea3-eba6d3f0feda.png?v=1737467253"},{"product_id":"isma-d-pd-rj45-usb","title":"ISMA-D-PD-RJ45-USB","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eUSB head -- RJ45 head, L=1500mm , UL2725 24\/1P+28#, 3.8 mm Cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321580380315,"sku":"ISMA-D-PD-RJ45-USB","price":11.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-D-PD-RJ45-USB-web.png?v=1737467218"},{"product_id":"isma-d-pa-usb","title":"ISMA-D-PA-USB","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eUSB 2.0 to USB A Cable for iSMA-D-PA10C-B1 and iSMA-D-PA15C-B1.\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e\u003c\/p\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321580544155,"sku":"ISMA-D-PA-USB","price":9.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-D-PA-USB.png?v=1737467217"},{"product_id":"fs-router-bac2","title":"FS-Router-BAC2","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eNow, you can easily convert any BACnet MSTP\/RS485 network to Bacnet IP using our BACnet Router. The BACnet Router will transparently turn 2 x BACnet MSTP\/RS485 networks each with up to 64 devices into BACnet IP.\u003cbr\u003e\u003cbr\u003eThis will help you integrate large Fan Coil Controller networks into your favourite¬†Niagara 4 Controller or Supervisor (Niagara 4 Supervisor\/IQVision etc, Jace 8000\/TONN\/HAWK, MAC6NL etc), as well as any other Bacnet IP-enabled controllers such as Trend IQ4, Schneider, Siemens and many others.\u003c\/p\u003e\n\u003cp\u003eThe BACnet Router provides stand-alone routing between BACnet networks such as BACnet\/IP, BACnet Ethernet, and BACnet MS\/TP, thereby allowing the system integrator to mix BACnet network technologies within a single BACnet internetwork. There are three physical communication ports on the\u003c\/p\u003e\n\u003cp\u003eBAS Router. One is a 10\/100 Mbps Ethernet port and the other two are RS-485 MS\/TP ports.\u003cbr\u003e\u003cbr\u003eThe configuration is accomplished via a web page. Just watch the instructions in this short 3-minute clip:\u003c\/p\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/2lK9JSXLiHU\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca title=\"Documentation \u0026amp; Downloads for FS‚ÄìRouter‚ÄìBAC2\" href=\"http:\/\/support.innon.com\/SierraMonitor\/FS-Router-BAC2\/\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" alt=\"Documentation \u0026amp; Downloads for FS‚ÄìRouter‚ÄìBAC2  style=\" float:=\"\" none=\"\"\u003e\u003c\/a\u003e\u003ca href=\"http:\/\/support.innon.com\/SierraMonitor\/FS-Router-BAC2\/\" title=\"Documentation \u0026amp; Downloads for FS‚ÄìRouter‚ÄìBAC2\"\u003e \u003c\/a\u003e","brand":"SierraMonitor","offers":[{"title":"Default Title","offer_id":37321727967387,"sku":"FS-Router-BAC2","price":428.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/files\/2.png?v=1737467157"},{"product_id":"mitsubishi-ac-mm-a20-kit","title":"MM-A20 Kit","description":"\u003ch5\u003eAbout the Product\u003c\/h5\u003e\n\u003cp\u003eMitsubishi MM-A20 inc 3 x PIP network card.¬†\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDo yo have a question about this product?\u003c\/b\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"https:\/\/support.innon.com\/BlackPear\/\" title=\"Documentation \u0026amp; Downloads for MM-A20 Kit\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for MM-A20 Kit  style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for MM-A20 Kit\" href=\"https:\/\/support.innon.com\/BlackPear\/\"\u003e \u003c\/a\u003e","brand":"Microtrol","offers":[{"title":"Default Title","offer_id":37321755459739,"sku":"MM-A20 Kit","price":1320.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ToshibaACBMSGateway1_c17f4881-1d06-4d15-8817-183d097732fd.png?v=1737467147"},{"product_id":"isma-b-lp-hc-1","title":"iSMA-B-LP-HC-1","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eiSMA-B-HC-1\u003c\/strong\u003e¬†is a room unit with \u003cstrong\u003e2.3‚Äù LCD\u003c\/strong\u003e display and four function buttons. Additionally, the room unit has the built-in temperature sensor and the humidity and CO\u003csub\u003e2\u003c\/sub\u003esensors.\u003c\/p\u003e\n\u003cp\u003eiSMA-B-LP-HC-1 is powered with 24 V AC\/DC and has the built-in ¬†RS485 port (\u003cstrong\u003eModbus RTU\/ASCII\u003c\/strong\u003e). Use of open communication protocol allows to connect the room unit with any controller supports Modbus RTU\/ASCII. Together with \u003ca href=\"https:\/\/www.innon.co.uk\/search?type=product\u0026amp;q=isma-b-fcu\" title=\"iSMA-B-FCU controllers\"\u003eiSMA-B-FCU \u003c\/a\u003econtroller, the room unit allows to change the basic parameters such as: temperature setpoint, fan speed, FCU mode and others.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThanks to built-in USB port, there is possibility to firmware update and room unit configuration without the necessity of power supply. iSMA-B-LP-HC-1 has the modern design and is available in different colours (white is basic) on client request.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-LP\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-LP-HC-1\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-LP-HC-1 style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-LP-HC-1\" href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-LP\/\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321866739867,"sku":"iSMA-B-LP-HC-1","price":514.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/iSMA-B-LP.png?v=1737467100"},{"product_id":"isma-b-lp-h-1","title":"iSMA-B-LP-H-1","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eiSMA-B-LP-H-1\u003c\/strong\u003e is a room unit with \u003cstrong\u003e2.3‚Äù LCD\u003c\/strong\u003e display and four function buttons. Additionally, the room unit has the built-in temperature sensor and the humidity¬†sensor.\u003c\/p\u003e\n\u003cp\u003eiSMA-B-LP-H-1 is powered with 24 V AC\/DC and has the built-in ¬†RS485 port (\u003cstrong\u003eModbus RTU\/ASCII\u003c\/strong\u003e). Use of open communication protocol allows to connect the room unit with any controller supports Modbus RTU\/ASCII. Together with \u003ca href=\"https:\/\/www.innon.co.uk\/search?type=product\u0026amp;q=isma-b-fcu\" title=\"iSMA-B-FCU controllers\"\u003eiSMA-B-FCU \u003c\/a\u003econtroller, the room unit allows to change the basic parameters such as: temperature setpoint, fan speed, FCU mode and others.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThanks to built-in USB port, there is possibility to firmware update and room unit configuration without the necessity of power supply. iSMA-B-LP-H-1 has the modern design and is available in different colours (white is basic) on client request.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-LP\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-LP-H-1\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-LP-H-1 style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-LP-H-1\" href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-LP\/\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321868607643,"sku":"iSMA-B-LP-H-1","price":208.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/LP-1_persp_72a74333-13bc-4896-aa92-48875ff102be.png?v=1737467099"},{"product_id":"isma-b-lp-c-1","title":"iSMA-B-LP-C-1","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eiSMA-B-LP-C-1\u003c\/strong\u003e is a room unit with \u003cstrong\u003e2.3‚Äù LCD\u003c\/strong\u003e display and four function buttons. Additionally, the room unit has the built-in temperature sensor CO\u003csub\u003e2\u003c\/sub\u003esensors.\u003c\/p\u003e\n\u003cp\u003eiSMA-B-LP-C-1 is powered with 24 V AC\/DC and has the built-in ¬†RS485 port (\u003cstrong\u003eModbus RTU\/ASCII\u003c\/strong\u003e). Use of open communication protocol allows to connect the room unit with any controller supports Modbus RTU\/ASCII. Together with \u003ca href=\"https:\/\/www.innon.co.uk\/search?type=product\u0026amp;q=isma-b-fcu\" title=\"iSMA-B-FCU controllers\"\u003eiSMA-B-FCU \u003c\/a\u003econtroller, the room unit allows to change the basic parameters such as: temperature setpoint, fan speed, FCU mode and others.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThanks to built-in USB port, there is possibility to firmware update and room unit configuration without the necessity of power supply. iSMA-B-LP-C-1 has the modern design and is available in different colours (white is basic) on client request.\u003c\/span\u003e\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-LP\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-LP-C-1\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-LP-C-1 style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-LP-C-1\" href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-LP\/\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321870737563,"sku":"iSMA-B-LP-C-1","price":445.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/iSMA-B-LP_9206478d-3a28-468f-9fa4-7f2afdac953e.png?v=1737467099"},{"product_id":"isma-b-lp-c","title":"iSMA-B-LP-C","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eiSMA-B-LP-C\u003c\/strong\u003e is a room unit with \u003cstrong\u003e2.3‚Äù LCD\u003c\/strong\u003e display and four function buttons. Additionally, the room unit has the built-in temperature sensor CO\u003csub\u003e2\u003c\/sub\u003esensors.\u003c\/p\u003e\n\u003cp\u003eiSMA-B-LP-C is powered with 24 V AC\/DC and has the built-in ¬†RS485 port (\u003cstrong\u003eModbus RTU\/ASCII\u003c\/strong\u003e). Use of open communication protocol allows to connect the room unit with any controller supports Modbus RTU\/ASCII. Together with \u003ca href=\"https:\/\/www.innon.co.uk\/search?type=product\u0026amp;q=isma-b-fcu\" title=\"iSMA-B-FCU controllers\"\u003eiSMA-B-FCU \u003c\/a\u003econtroller, the room unit allows to change the basic parameters such as: temperature setpoint, fan speed, FCU mode and others.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThanks to built-in USB port, there is possibility to firmware update and room unit configuration without the necessity of power supply. iSMA-B-LP has the modern design and is available in different colours (white is basic) on client request.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-LP\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-LP-C\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-LP-C style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-LP-C\" href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-LP\/\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321871163547,"sku":"iSMA-B-LP-C","price":445.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/iSMA-B-LP_f9826365-3359-4365-827a-205486b179e2.png?v=1737467098"},{"product_id":"isma-b-lp-1","title":"iSMA-B-LP-1","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eiSMA-B-LP-1\u003c\/strong\u003e is a room unit with \u003cstrong\u003e2.3‚Äù LCD\u003c\/strong\u003e display and four function buttons. Additionally, the room unit has the built-in temperature sensor and optionally the humidity and CO\u003csub\u003e2\u003c\/sub\u003esensors.\u003c\/p\u003e\n\u003cp\u003eiSMA-B-LP-1 is powered with 24 V AC\/DC and has the built-in ¬†RS485 port (\u003cstrong\u003eModbus RTU\/ASCII\u003c\/strong\u003e). Use of open communication protocol allows to connect the room unit with any controller supports Modbus RTU\/ASCII. Together with \u003ca title=\"iSMA-B-FCU controllers\" href=\"https:\/\/www.innon.co.uk\/search?type=product\u0026amp;q=isma-b-fcu\"\u003eiSMA-B-FCU \u003c\/a\u003econtroller, the room unit allows to change the basic parameters such as: temperature setpoint, fan speed, FCU mode and others.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThanks to built-in USB port, there is possibility to firmware update and room unit configuration without the necessity of power supply. iSMA-B-LP-1 has the modern design and is available in different colours (white is basic) on client request.\u003c\/span\u003e\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-LP\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-LP-1\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-LP-1 style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-LP-1\" href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-LP\/\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321871556763,"sku":"iSMA-B-LP-1","price":108.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-B-LP-1-600x600_png.png?v=1737467097"},{"product_id":"isma-b-2d-wd","title":"iSMA-B-2D-WD","description":"\u003ch5\u003eAbout the product¬†\u003c\/h5\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003eiSMA-B-2D1B has been built in order to control light and a blind\/shutter motor in a single space in the building. The device is dedicated to control two separate DALI light areas with up to 32 DALI ballasts. Built-in two Special Inputs and two Digital Inputs are dedicated to connect presence detectors and light switches. Dedicated DIP-switch allows to activate predefined inputs configuration. Out of box the device allows to control the DALI ballasts by a common light switch and a common presence detector without the need of programming, which makes iSMA-B-2D1B the unique plug\u0026amp; play type device dedicated to DALI network control. In addition iSMA-B-2D1B has blind\/shutter control function implemented, which allows to control a blind\/shutter motor by a common double-switch. The controller is factory-equipped with the RS485 interface which is the physical layer for the most popular open communication protocol Modbus ASCII\/RTU.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAddressing from 0 to 255 by DIP-switch\u003c\/li\u003e\n\u003cli\u003e230 V AC power supply\u003c\/li\u003e\n\u003cli\u003eDedicated DIP-switch for inputs configuration\u003c\/li\u003e\n\u003cli\u003eFast processor with ARM core\u003c\/li\u003e\n\u003cli\u003eModbus ASCII\/RTU or for connecting to higher level system over RS485 ‚Ä¢ 2x DALI Interface: built-in power supply for up to 16 ballasts each\u003c\/li\u003e\n\u003cli\u003eSpecial and Digital Inputs for present detectors and light and blind switches connection\u003c\/li\u003e\n\u003cli\u003e2x power supply outputs for ballasts (fuse protected)\u003c\/li\u003e\n\u003cli\u003e1x power supply output for blind motor (fuse protected)\u003c\/li\u003e\n\u003cli\u003eBuilt-in 24 V DC for an external equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cmeta charset=\"utf-8\"\u003e\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e\u003cbr\u003e‚Ä¢ 2x Special Input ‚Äì dry contact\u003cbr\u003e‚Ä¢ 4x Digital Input ‚Äì dry contact\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e\u003cbr\u003e‚Ä¢ 2x Light output 230 V AC max. 4 A\u003cbr\u003e‚Ä¢ 1x Motor Output 230 V AC max. 1,5 A\u003cbr\u003e‚Ä¢ 1x Power Supply Output 24V DC max. 80 mA\u003cbr\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/em\u003e! Max. current for all the outputs is 8 A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003cbr\u003e‚Ä¢ 230 V AC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003cbr\u003e‚Ä¢ Operating temperature: 0¬∞C to 50¬∞C\u003cbr\u003e‚Ä¢ Storage temperature: -40¬∞C to 85¬∞C\u003cbr\u003e‚Ä¢ Relative humidity: 5% to 95%, no condensation\u003cbr\u003e‚Ä¢ Ingress Protection Rating: IP40 ‚Äì for indoor\u003cbr\u003einstallation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlatform\u003c\/strong\u003e\u003cbr\u003e‚Ä¢ ARM Cortex ‚Äì M4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003cbr\u003eRS485 Interface:ÔÄ†\u003cbr\u003e‚Ä¢ Interface RS485 half-duplex\u003cbr\u003e‚Ä¢ Up to 128 devices on bus\u003cbr\u003e‚Ä¢ Protocols: Modbus\u003cbr\u003e‚Ä¢ Baud rate: 2400 to 115200 bps\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDALI Interface:\u003c\/strong\u003e\u003cbr\u003e‚Ä¢ 2x separate DALI Interface: built-in power supply max.\u003cbr\u003e40 mA\u003cbr\u003e‚Ä¢ Up to 16 DALI ballasts per interface\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003cbr\u003e‚Ä¢ Dimension: 123,6x136,6x54,5 mm, (123,6x171,2x54,9\u003cbr\u003emm with plastic cover for terminals)\u003cbr\u003e‚Ä¢ Construction: plastic, self-extinguishing (PC\/ABS)\u003cbr\u003e‚Ä¢ DIN rail mounting DIN (DIN EN 50022 norm)\u003cbr\u003e‚Ä¢ Cooling: internal air circulation\u003c\/p\u003e\n\u003cp\u003eDo you have a question about this product\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-2D\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-2D-WD\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-2D-WD style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-2D-WD\" href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-2D\/\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321893085339,"sku":"iSMA-B-2D-WD","price":251.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/isma-b-2d-wd-600x600_png.png?v=1737467085"},{"product_id":"isma-b-2d","title":"iSMA-B-2D","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003eiSMA-B-2D has been built in order to control light and a blind\/shutter motor in a single space in the building. The device is dedicated to control two separate DALI light areas with up to 32 DALI ballasts. Built-in two Special Inputs and two Digital Inputs are dedicated to connect presence detectors and light switches. Dedicated DIP-switch allows to activate predefined inputs configuration. Out of box the device allows to control the DALI ballasts by a common light switch and a common presence detector without the need of programming, which makes iSMA-B-2D1B the unique plug\u0026amp; play type device dedicated to DALI network control. In addition iSMA-B-2D1B has blind\/shutter control function implemented, which allows to control a blind\/shutter motor by a common double-switch. The controller is factory-equipped with the RS485 interface which is the physical layer for the most popular open communication protocol Modbus ASCII\/RTU.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e‚Ä¢ Addressing from 0 to 255 by DIP-switch\u003c\/p\u003e\n\u003cp\u003e‚Ä¢ 230 V AC power supply\u003c\/p\u003e\n\u003cp\u003e‚Ä¢ Dedicated DIP-switch for inputs configuration\u003c\/p\u003e\n\u003cp\u003e‚Ä¢ Fast processor with ARM core\u003c\/p\u003e\n\u003cp\u003e‚Ä¢ Modbus ASCII\/RTU or for connecting to higher level system over RS485 ‚Ä¢ 2x DALI Interface: built-in power supply for up to 16 ballasts each\u003c\/p\u003e\n\u003cp\u003e‚Ä¢ Special and Digital Inputs for present detectors and light and blind switches connection\u003c\/p\u003e\n\u003cp\u003e‚Ä¢ 2x power supply outputs for ballasts (fuse protected)\u003c\/p\u003e\n\u003cp\u003e‚Ä¢ 1x power supply output for blind motor (fuse protected)\u003c\/p\u003e\n\u003cp\u003e‚Ä¢ Built-in 24 V DC for an external equipment\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e‚Ä¢ 2x Special Input ‚Äì dry contact\u003cbr\u003e‚Ä¢ 4x Digital Input ‚Äì dry contact\u003cbr\u003eOutputs\u003cbr\u003e‚Ä¢ 2x Light output 230 V AC max. 4 A\u003cbr\u003e‚Ä¢ 1x Motor Output 230 V AC max. 1,5 A\u003cbr\u003e‚Ä¢ 1x Power Supply Output 24V DC max. 80 mA\u003cbr\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/em\u003e! Max. current for all the outputs is 8 A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003cbr\u003e‚Ä¢ 230 V AC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003cbr\u003e‚Ä¢ Operating temperature: 0¬∞C to 50¬∞C\u003cbr\u003e‚Ä¢ Storage temperature: -40¬∞C to 85¬∞C\u003cbr\u003e‚Ä¢ Relative humidity: 5% to 95%, no condensation\u003cbr\u003e‚Ä¢ Ingress Protection Rating: IP40 ‚Äì for indoor\u003cbr\u003einstallation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlatform\u003c\/strong\u003e\u003cbr\u003e‚Ä¢ ARM Cortex ‚Äì M4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003cbr\u003eRS485 Interface:ÔÄ†\u003cbr\u003e‚Ä¢ Interface RS485 half-duplex\u003cbr\u003e‚Ä¢ Up to 128 devices on bus\u003cbr\u003e‚Ä¢ Protocols: Modbus\u003cbr\u003e‚Ä¢ Baud rate: 2400 to 115200 bps\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDALI Interface:\u003c\/strong\u003e\u003cbr\u003e‚Ä¢ 2x separate DALI Interface: built-in power supply max.\u003cbr\u003e40 mA\u003cbr\u003e‚Ä¢ Up to 16 DALI ballasts per interface\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003cbr\u003e‚Ä¢ Dimension: 123,6x136,6x54,5 mm, (123,6x171,2x54,9\u003cbr\u003emm with plastic cover for terminals)\u003cbr\u003e‚Ä¢ Construction: plastic, self-extinguishing (PC\/ABS)\u003cbr\u003e‚Ä¢ DIN rail mounting DIN (DIN EN 50022 norm)\u003cbr\u003e‚Ä¢ Cooling: internal air circulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-2D\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-2D\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-2D style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-2D\" href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-2D\/\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321893970075,"sku":"iSMA-B-2D","price":227.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/isma-b-2D-600x600.png?v=1737467085"},{"product_id":"isma-b-2d1b-wd","title":"iSMA-B-2D1B-WD","description":"\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eiSMA-B-2D1B has been built in order to control light and a blind\/shutter motor in a single space in the building. The device is dedicated to control two separate DALI light areas with up to 32 DALI ballasts. Built-in two Special Inputs and two Digital Inputs are dedicated to connect presence detectors and light switches. Dedicated DIP-switch allows to activate predefined inputs configuration. Out of box the device allows to control the DALI ballasts by a common light switch and a common presence detector without the need of programming, which makes iSMA-B-2D1B the unique plug\u0026amp; play type device dedicated to DALI network control. In addition iSMA-B-2D1B has blind\/shutter control function implemented, which allows to control a blind\/shutter motor by a common double-switch. The controller is factory-equipped with the RS485 interface which is the physical layer for the most popular open communication protocol Modbus ASCII\/RTU.\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e‚Ä¢ Addressing from 0 to 255 by DIP-switch \u003cbr\u003e ‚Ä¢ 230 V AC power supply\u003cbr\u003e ‚Ä¢ Dedicated DIP-switch for inputs configuration\u003cbr\u003e ‚Ä¢ Fast processor with ARM core\u003cbr\u003e ‚Ä¢ Modbus ASCII\/RTU or for connecting to higher level system over RS485\u003cbr\u003e ‚Ä¢ 2x DALI Interface: built-in power supply for up to 16 ballasts each\u003cbr\u003e ‚Ä¢ Special and Digital Inputs for present detectors and light and blind switches connection\u003cbr\u003e ‚Ä¢ 2x power supply outputs for ballasts (fuse protected)\u003cbr\u003e ‚Ä¢ 1x power supply output for blind motor (fuse protected)\u003cbr\u003e ‚Ä¢ Built-in 24 V DC for an external equipment\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e\u003cbr\u003e‚Ä¢ 2x Special Input ‚Äì dry contact\u003cbr\u003e‚Ä¢ 4x Digital Input ‚Äì dry contact\u003cbr\u003eOutputs\u003cbr\u003e‚Ä¢ 2x Light output 230 V AC max. 4 A\u003cbr\u003e‚Ä¢ 1x Motor Output 230 V AC max. 1,5 A\u003cbr\u003e‚Ä¢ 1x Power Supply Output 24V DC max. 80 mA\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cem\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e! Max. current for all the outputs is 8 A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003cbr\u003e‚Ä¢ 230 V AC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003cbr\u003e‚Ä¢ Operating temperature: 0¬∞C to 50¬∞C\u003cbr\u003e‚Ä¢ Storage temperature: -40¬∞C to 85¬∞C\u003cbr\u003e‚Ä¢ Relative humidity: 5% to 95%, no condensation\u003cbr\u003e‚Ä¢ Ingress Protection Rating: IP40 ‚Äì for indoor\u003cbr\u003einstallation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlatform\u003c\/strong\u003e\u003cbr\u003e‚Ä¢ ARM Cortex ‚Äì M4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003cbr\u003eRS485 Interface:ÔÄ†\u003cbr\u003e‚Ä¢ Interface RS485 half-duplex\u003cbr\u003e‚Ä¢ Up to 128 devices on bus\u003cbr\u003e‚Ä¢ Protocols: Modbus\u003cbr\u003e‚Ä¢ Baud rate: 2400 to 115200 bps\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDALI Interface:\u003c\/strong\u003e\u003cbr\u003e‚Ä¢ 2x separate DALI Interface: built-in power supply max.\u003cbr\u003e40 mA\u003cbr\u003e‚Ä¢ Up to 16 DALI ballasts per interface\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003cbr\u003e‚Ä¢ Dimension: 123,6x136,6x54,5 mm, (123,6x171,2x54,9\u003cbr\u003emm with plastic cover for terminals)\u003cbr\u003e‚Ä¢ Construction: plastic, self-extinguishing (PC\/ABS)\u003cbr\u003e‚Ä¢ DIN rail mounting DIN (DIN EN 50022 norm)\u003cbr\u003e‚Ä¢ Cooling: internal air circulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-2D1B\/\" title=\"Documentation \u0026amp; Downloads for iSMA-2D1B-WD\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-D1B-WD style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-2D1b-WD\" href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-2D1B\/\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321895182491,"sku":"iSMA-B-2D1B-WD","price":297.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/isma-b-2D1B-WD-600x600_png.png?v=1737467084"},{"product_id":"isma-b-2d1b","title":"iSMA-B-2D1B","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003eiSMA-B-2D1B has been built in order to control light and a blind\/shutter motor in a single space in the building. The device is dedicated to control two separate DALI light areas with up to 32 DALI ballasts. Built-in two Special Inputs and two Digital Inputs are dedicated to connect presence detectors and light switches. Dedicated DIP-switch allows to activate predefined inputs configuration. Out of box the device allows to control the DALI ballasts by a common light switch and a common presence detector without the need of programming, which makes iSMA-B-2D1B the unique plug\u0026amp; play type device dedicated to DALI network control. In addition iSMA-B-2D1B has blind\/shutter control function implemented, which allows to control a blind\/shutter motor by a common double-switch. The controller is factory-equipped with the RS485 interface which is the physical layer for the most popular open communication protocol Modbus ASCII\/RTU.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e‚Ä¢ Addressing from 0 to 255 by DIP-switch \u003cbr\u003e ‚Ä¢ 230 V AC power supply\u003cbr\u003e ‚Ä¢ Dedicated DIP-switch for inputs configuration\u003cbr\u003e ‚Ä¢ Fast processor with ARM core\u003cbr\u003e ‚Ä¢ Modbus ASCII\/RTU or for connecting to higher level system over RS485\u003cbr\u003e ‚Ä¢ 2x DALI Interface: built-in power supply for up to 16 ballasts each\u003cbr\u003e ‚Ä¢ Special and Digital Inputs for present detectors and light and blind switches connection\u003cbr\u003e ‚Ä¢ 2x power supply outputs for ballasts (fuse protected)\u003cbr\u003e ‚Ä¢ 1x power supply output for blind motor (fuse protected)\u003cbr\u003e ‚Ä¢ Built-in 24 V DC for an external equipment\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e\u003cbr\u003e ‚Ä¢ 2x Special Input ‚Äì dry contact\u003cbr\u003e‚Ä¢ 4x Digital Input ‚Äì dry contact\u003cbr\u003eOutputs\u003cbr\u003e‚Ä¢ 2x Light output 230 V AC max. 4 A\u003cbr\u003e‚Ä¢ 1x Motor Output 230 V AC max. 1,5 A\u003cbr\u003e‚Ä¢ 1x Power Supply Output 24V DC max. 80 mA\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cem\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e! Max. current for all the outputs is 8 A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003cbr\u003e‚Ä¢ 230 V AC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003cbr\u003e‚Ä¢ Operating temperature: 0¬∞C to 50¬∞C\u003cbr\u003e‚Ä¢ Storage temperature: -40¬∞C to 85¬∞C\u003cbr\u003e‚Ä¢ Relative humidity: 5% to 95%, no condensation\u003cbr\u003e‚Ä¢ Ingress Protection Rating: IP40 ‚Äì for indoor installation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlatform\u003c\/strong\u003e\u003cbr\u003e‚Ä¢ ARM Cortex ‚Äì M4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003cbr\u003eRS485 Interface:ÔÄ†\u003cbr\u003e‚Ä¢ Interface RS485 half-duplex\u003cbr\u003e‚Ä¢ Up to 128 devices on bus\u003cbr\u003e‚Ä¢ Protocols: Modbus\u003cbr\u003e‚Ä¢ Baud rate: 2400 to 115200 bps\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDALI Interface:\u003c\/strong\u003e\u003cbr\u003e‚Ä¢ 2x separate DALI Interface: built-in power supply max.\u003cbr\u003e40 mA\u003cbr\u003e‚Ä¢ Up to 16 DALI ballasts per interface\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003cbr\u003e‚Ä¢ Dimension: 123,6x136,6x54,5 mm, (123,6x171,2x54,9 mm with plastic cover for terminals)\u003cbr\u003e‚Ä¢ Construction: plastic, self-extinguishing (PC\/ABS)\u003cbr\u003e‚Ä¢ DIN rail mounting DIN (DIN EN 50022 norm)\u003cbr\u003e‚Ä¢ Cooling: internal air circulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-2D1B\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-2D1B\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-2D1B style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-2D1B\" href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-2D1B\/\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37321896788123,"sku":"iSMA-B-2D1B","price":273.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/isma-b-2D1B--600x600_png.png?v=1737467083"},{"product_id":"isma-b-aac20-lcd-m","title":"iSMA-B-AAC20-LCD-M","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eiSMA-B-AAC20-LCD-M controller (iSMA-B-AAC20)¬†with \u003cstrong\u003einbuilt display and M-Bus for up to 20 devices\u003c\/strong\u003e¬†is an advanced device to control building automation and HVAC systems. Use of SVM (Sedona Virtual Machine) allows you to finish the setup quickly and easily. It is ideal for smaller projects where you want to stay open protocol while keeping the development simple and the cost under budget.\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003eBig, fully programmable LCD can be used as simple user interface to allows local operation of system. The Mbus¬†Interface¬†allows you to pick up max 20 meters.\u003c\/p\u003e\n\u003cp\u003eWith the large number of inputs and outputs allows to integrate with other devices and sensors (AAC20 provides 8xUI, 4xDI, 4\/6xAO and 4xDO). Its fast processor allows to control of even very large objects. Built-in RS485 can be used to expand number of I\/O by connecting MINI or MIX series I\/O modules using Modbus ASCII\/RTU. In addition, to increase the versatility of the controller, it supports many open communications protocols like: BACnet, Modbus, SOX, DALI, M-Bus, 1-wire or oBIX (optional). AAC20 is mounted in a housing adapted for DIN rail mounting or directly on a panel. Separate, easy to remove connectors allow quick wiring without removing the entire module.\u003c\/p\u003e\n\u003cstrong\u003eInputs \u0026amp; Outputs\u003c\/strong\u003e\u003cbr\u003e8xUniversal Inputs (8UI)\u003cbr\u003eAll universal inputs have 16-bit resolution which support the following types of inputs:\n\u003cul\u003e\n\u003cli\u003eTemperature input support the following types of sensors: 10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1, Pt1000, Ni1000\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cb\u003eFor sensor Pt1000 and Ni1000 use only 16bit resolution\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage input 0-10VDC: input resistance 100kŒ© accuracy ¬±0,1% measurement resolution 3mV@12bit and 1mV@16bit\u003c\/li\u003e\n\u003cli\u003eCurrent input 0-20mA (external resistor 499Œ© required)\u003c\/li\u003e\n\u003cli\u003eResistive input 0-1000kŒ©: measurement resolution for 20kŒ© load 20Œ©@12bit and 1Œ©@16bit\u003c\/li\u003e\n\u003cli\u003eDry contact input\u003c\/li\u003e\n\u003c\/ul\u003e\n4 x Digital Inputs (4DI)\n\u003cul\u003e\n\u003cli\u003eDry contact inputs\u003c\/li\u003e\n\u003cli\u003eFast pulse counter up to 100Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n4\/6 x Analog Outputs (4\/6AO)\u003cbr\u003eAll analog outputs are equipped with 12-bit ADC provides10 mV resolution and accuracy less than ¬±0,5%. They support the following output types:\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eOutput 0-10V DC maximum load up to 20mA(5mA- AO6)\u003c\/li\u003e\n\u003cli\u003ePWM: 0,01Hz, 0,1Hz, 1Hz, 10Hz, 100Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\nAO5 and AO6 can only be used if 1-wire port is not in use, please notice for AO6 maximum current load is up to 5mA \u003cbr\u003e4 x Digital Outputs (4DO)\n\u003cul\u003e\n\u003cli\u003eRelay output (NO) max. 3A, 250 VAC\/30 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003ePlatform\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eARM Cortex-M4 204MHz\u003c\/li\u003e\n\u003cli\u003eARM Cortex-M0 204MHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eCommunication\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eInterface RS485 half duplex\u003c\/li\u003e\n\u003cli\u003eBaud rate: 2400 to 115200 bps\u003c\/li\u003e\n\u003cli\u003e2xEthernet with built in switch\u003c\/li\u003e\n\u003cli\u003e1-Wire Interface\u003c\/li\u003e\n\u003cli\u003eMicro SD card slot\u003c\/li\u003e\n\u003cli\u003eUSB Host Interface\u003c\/li\u003e\n\u003cli\u003eProtocols: Modbus, BACnet, 1-wire, oBIX\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003ePower supply\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e24V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eHousing\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eDimension: 106x110x62 mm.\u003c\/li\u003e\n\u003cli\u003eConstruction: plastic, self-extinguishing (PC\/ABS)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting (DIN EN 50022 norm)\u003c\/li\u003e\n\u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eEnvironments\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature: -10¬∞C to 50¬∞C\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40¬∞C to 85¬∞C\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 5 to 95%, no condensation\u003c\/li\u003e\n\u003cli\u003eIngress Protection Rating: IP40 ‚Äì for indoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-AAC20\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-AAC20-LCD-M\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-AAC20-LCD-M style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-AAC20-LCD-M\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-AAC20\/\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37322072686747,"sku":"iSMA-B-AAC20-LCD-M","price":1025.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/isma-b-aac20-m-lcd-600x600.png?v=1737467019"},{"product_id":"isma-b-aac20-m","title":"iSMA-B-AAC20-M","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eiSMA-B-AAC20-M controller (iSMA-B-AAC20)¬†with \u003cstrong\u003eM-Bus for up to 20 devices\u003c\/strong\u003e¬†is an advanced device to control building automation and HVAC systems. Use of SVM (Sedona Virtual Machine) allows you to finish the setup quickly and easily. It is ideal for smaller projects where you want to stay open protocol while keeping the development simple and the cost under budget.\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003eThe Mbus¬†Interface¬†allows you to pick up max 20 meters.\u003c\/p\u003e\n\u003cp\u003eWith the large number of inputs and outputs allows to integrate with other devices and sensors (AAC20 provides 8xUI, 4xDI, 4\/6xAO and 4xDO). Its fast processor allows to control of even very large objects. Built-in RS485 can be used to expand number of I\/O by connecting MINI or MIX series I\/O modules using Modbus ASCII\/RTU. In addition, to increase the versatility of the controller, it supports many open communications protocols like: BACnet, Modbus, SOX, DALI, M-Bus, 1-wire or oBIX (optional). AAC20 is mounted in a housing adapted for DIN rail mounting or directly on a panel. Separate, easy to remove connectors allow quick wiring without removing the entire module.\u003c\/p\u003e\n\u003cstrong\u003eInputs \u0026amp; Outputs\u003c\/strong\u003e\u003cbr\u003e8xUniversal Inputs (8UI)\u003cbr\u003eAll universal inputs have 16-bit resolution which support the following types of inputs:\n\u003cul\u003e\n\u003cli\u003eTemperature input support the following types of sensors: 10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1, Pt1000, Ni1000\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cb\u003eFor sensor Pt1000 and Ni1000 use only 16bit resolution\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage input 0-10VDC: input resistance 100kŒ© accuracy ¬±0,1% measurement resolution 3mV@12bit and 1mV@16bit\u003c\/li\u003e\n\u003cli\u003eCurrent input 0-20mA (external resistor 499Œ© required)\u003c\/li\u003e\n\u003cli\u003eResistive input 0-1000kŒ©: measurement resolution for 20kŒ© load 20Œ©@12bit and 1Œ©@16bit\u003c\/li\u003e\n\u003cli\u003eDry contact input\u003c\/li\u003e\n\u003c\/ul\u003e\n4 x Digital Inputs (4DI)\n\u003cul\u003e\n\u003cli\u003eDry contact inputs\u003c\/li\u003e\n\u003cli\u003eFast pulse counter up to 100Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n4\/6 x Analog Outputs (4\/6AO)\u003cbr\u003eAll analog outputs are equipped with 12-bit ADC provides10 mV resolution and accuracy less than ¬±0,5%. They support the following output types:\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eOutput 0-10V DC maximum load up to 20mA(5mA- AO6)\u003c\/li\u003e\n\u003cli\u003ePWM: 0,01Hz, 0,1Hz, 1Hz, 10Hz, 100Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\nAO5 and AO6 can only be used if 1-wire port is not in use, please notice for AO6 maximum current load is up to 5mA \u003cbr\u003e4 x Digital Outputs (4DO)\n\u003cul\u003e\n\u003cli\u003eRelay output (NO) max. 3A, 250 VAC\/30 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003ePlatform\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eARM Cortex-M4 204MHz\u003c\/li\u003e\n\u003cli\u003eARM Cortex-M0 204MHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eCommunication\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eInterface RS485 half duplex\u003c\/li\u003e\n\u003cli\u003eBaud rate: 2400 to 115200 bps\u003c\/li\u003e\n\u003cli\u003e2xEthernet with built in switch\u003c\/li\u003e\n\u003cli\u003e1-Wire Interface\u003c\/li\u003e\n\u003cli\u003eMicro SD card slot\u003c\/li\u003e\n\u003cli\u003eUSB Host Interface\u003c\/li\u003e\n\u003cli\u003eProtocols: Modbus, BACnet, 1-wire, oBIX\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003ePower supply\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e24V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eHousing\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eDimension: 106x110x62 mm.\u003c\/li\u003e\n\u003cli\u003eConstruction: plastic, self-extinguishing (PC\/ABS)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting (DIN EN 50022 norm)\u003c\/li\u003e\n\u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eEnvironments\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature: -10¬∞C to 50¬∞C\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40¬∞C to 85¬∞C\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 5 to 95%, no condensation\u003c\/li\u003e\n\u003cli\u003eIngress Protection Rating: IP40 ‚Äì for indoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-AAC20-M\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-AAC20\/\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" alt=\"Documentation \u0026amp; Downloads for iSMA-B-AAC20-M style=\" float:=\"\" none=\"\"\u003e\u003c\/a\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-AAC20\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-AAC20-M\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37322072981659,"sku":"iSMA-B-AAC20-M","price":903.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/isam-b-aac20-m-600x600.png?v=1737467018"},{"product_id":"isma-b-mg-ip","title":"iSMA-B-MG-IP","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003eOur new iSMA-B-MG-IP has been designed to simplify the connection of meters installation with BMS. By applying the most popular interfaces for M-Bus and Modbus meters. iSMA-B-MG-IP allows to handle up to 180 meters of various types simultaneously.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003eThe M-Bus interface allows to communicate and supply with¬†power up to 60 M-Bus meters. The RS485 interface allows to connect up to 128 Modbus devices. The device address and baud rate for Modbus are set by using DIP switches.The built-in TCP\/IP interface provides the ability to use the existing LAN infrastructure, also allows to build a scattered meters monitoring systems.\u003cbr\u003e\u003cbr\u003eiSMA-B-MG-IP device configuration is possible from the built-in web services level, and by using free tool such as iSMA Configurator.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MG-IP\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-MG-IP\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-MG-IP  style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-MG-IP\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MG-IP\/\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37322080485531,"sku":"iSMA-B-MG-IP","price":492.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-B-MG-IP-600x600.png?v=1737467007"},{"product_id":"isma-b-fcu-ll","title":"iSMA-B-FCU-LL","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan face=\"trebuchet ms, lucida grande, lucida sans unicode, lucida sans, tahoma, sans-serif\"\u003e\u003cspan\u003eThis fan coil controller¬†\u003c\/span\u003eis designed to¬†remove the current frustration with available products. It has the best of everything from ease of use to flexibility and price. Here are the top 6 reasons why you would choose this Fan Coil Controller for your next project.\u003cbr\u003e\u003cbr\u003e1. It comes pre-loaded with software templates\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003ecovering over 95% of requirements\u003c\/strong\u003e. And even if you have to change something changes are minimal.\u003cbr\u003e\u003cbr\u003e2. It is fully programmable with our\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003eiSMA Tool,\u003c\/strong\u003e\u003cspan\u003e¬†\u003c\/span\u003eand you do not need any previous experience or specialised training.\u003cbr\u003e\u003cbr\u003e3. It has the most\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003egenerous IO\u003c\/strong\u003e:¬†4 Universal \/ Special Inputs, 4 Digital Inputs, 3 Analog Outputs, three fan speed relays, relay for the electric heater, relay for electric cooler, 2 Triac Outputs for heating and cooling valves and\u003cbr\u003e\u003cbr\u003e4. It¬†supports a wide range of Universal Inputs sensors, and by default, it\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003ecan read any 10K3 sensors.\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e5. It has¬†a¬†builtin 24 Volt transformer which can\u003cspan\u003e¬†\u003c\/span\u003epower most actuator valves in the market.\u003cbr\u003e\u003cbr\u003e6. It has two communication ports:\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan face=\"trebuchet ms, lucida grande, lucida sans unicode, lucida sans, tahoma, sans-serif\"\u003eOne to be used with\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003eany Modus or\u003cspan\u003e¬†\u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003eBACnet\u003c\/strong\u003e\u003cstrong\u003e\u003cspan\u003e¬†\u003c\/span\u003eBMS Controller\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan face=\"trebuchet ms, lucida grande, lucida sans unicode, lucida sans, tahoma, sans-serif\"\u003eAnd the second one to be used with\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003eany Modbus Display\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTo set it up for the existing configuration is super easy just follow this video all you need is a screwdriver:\u003c\/p\u003e\n\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/GPkjgTqDKIY\" width=\"560\" height=\"315\" allow=\"accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen=\"\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003eIt is so easy to programme it using our iSMA Tool. You do not need any previous experience or specialized training to be able to use it.¬†\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1144\/2302\/files\/iSMAFCU_large.gif?v=1549976290\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e‚Ä¢ Preloaded universal application\u003c\/span\u003e\u003cbr\u003e‚Ä¢ Support 2-pipe or 4-pipe system\u003cbr\u003e‚Ä¢ Adjust application by dedicated DIP-switch\u003cbr\u003e‚Ä¢ Addressing from 0 to 255 by DIP-switch\u003cbr\u003e‚Ä¢ Sedona Framework 1.2 support\u003cbr\u003e‚Ä¢ Programming in real-time\u003cbr\u003e‚Ä¢ Built-in 18 Inputs\/Outputs\u003cbr\u003e‚Ä¢ Fast processor with ARM core\u003cbr\u003e‚Ä¢ Modbus ASCII\/RTU or BACnet MSTP\u003cbr\u003e‚Ä¢ 2 x RJ12 for connecting wall panels, external devices communicating in Modbus\u003cbr\u003e‚Ä¢ Built-in 24 V AC for an external equipment (version 230 V AC).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInputs \u0026amp; Outputs\u003c\/strong\u003e\u003cbr\u003e4x Special Input - voltage, resistance, dry contact\u003cbr\u003e4x Digital Input ‚Äì dry contact \u003cbr\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e\u003cbr\u003e3x Digital Output 6 A (Fan Speed)\u003cbr\u003e1x Digital Output 10 A (electric heater)\u003cbr\u003e1x Digital Output 6 A (cooling actuator)\u003cbr\u003e2x Triac 0,5 A @ 230 V AC or 0,5 A\/0,3 A* @ 24 V AC (heating and cooling, actuators)\u003cbr\u003e3x Analog Outputs 0-10 V DC (heating, cooling actuators and Fan Speed)\u003cbr\u003e\u003cstrong\u003ePlatform\u003c\/strong\u003e\u003cbr\u003eARM Cortex-M4\u003cbr\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003cbr\u003e230 V AC or 24 V AC\u003cbr\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003cbr\u003eInterface RS485 half duplex\u003cbr\u003eUp to 128 devices on the bus\u003cbr\u003eProtocols: Modbus or BACnet\u003cbr\u003eBaud rate: 4800 to 115200 bps\u003cbr\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003cbr\u003eDimension: 123,6x136,6x54,5 mm, (123,6x171,2x54,9 mm) with plastic cover for terminals\u003cbr\u003eConstruction: plastic, self-extinguishing (PC\/ABS)\u003cbr\u003eDIN rail mounting DIN (DIN EN 50022 norm)\u003cbr\u003eCooling: internal air circulation\u003cbr\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003cbr\u003eOperating temperature: -10¬∞C to 50¬∞C\u003cbr\u003eStorage temperature: -40¬∞C to 85¬∞C\u003cbr\u003eRelative humidity: 5% to 95%, no condensation\u003cbr\u003eIngress Protection Rating: IP40 ‚Äì for indoor installation¬†\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-FCU\/\" target=\"_blank\" title=\"Documentation \u0026amp; Downloads for iSMA-B-FCU-LL\" rel=\"noopener\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-FCU-LL style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-FCU-LL\" href=\"https:\/\/support.innon.com\/%20iSMA\/iSMA-B-FCU\/\"\u003e \u003c\/a\u003e\u003c\/p\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37322086547611,"sku":"iSMA-B-FCU-LL","price":227.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/iSMA-B-FCU-LL-600x600.png?v=1737467000"},{"product_id":"isma-b-fcu-hl","title":"iSMA-B-FCU-HL","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan face=\"trebuchet ms, lucida grande, lucida sans unicode, lucida sans, tahoma, sans-serif\"\u003e\u003cspan\u003eThis fan coil controller¬†\u003c\/span\u003eis designed to¬†remove the current frustration with available products. It has the best of everything from ease of use to flexibility and price. Here are the top 6 reasons why you would choose this Fan Coil Controller for your next project.\u003cbr\u003e\u003cbr\u003e1. It comes pre-loaded with software templates\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003ecovering over 95% of requirements\u003c\/strong\u003e. And even if you have to change something changes are minimal.\u003cbr\u003e\u003cbr\u003e2. It is fully programmable with our\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003eiSMA Tool,\u003c\/strong\u003e\u003cspan\u003e¬†\u003c\/span\u003eand you do not need any previous experience or specialised training.\u003cbr\u003e\u003cbr\u003e3. It has the most\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003egenerous IO\u003c\/strong\u003e:¬†4 Universal \/ Special Inputs, 4 Digital Inputs, 3 Analog Outputs, three fan speed relays, relay for the electric heater, relay for electric cooler, 2 Triac Outputs for heating and cooling valves and\u003cbr\u003e\u003cbr\u003e4. It¬†supports a wide range of Universal Inputs sensors, and by default, it\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003ecan read any 10K3 sensors.\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e5. It has¬†a¬†builtin 24 Volt transformer which can\u003cspan\u003e¬†\u003c\/span\u003epower most actuator valves in the market.\u003cbr\u003e\u003cbr\u003e6. It has two communication ports:\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan face=\"trebuchet ms, lucida grande, lucida sans unicode, lucida sans, tahoma, sans-serif\"\u003eOne to be used with\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003eany Modus or\u003cspan\u003e¬†\u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003eBACnet\u003c\/strong\u003e\u003cstrong\u003e\u003cspan\u003e¬†\u003c\/span\u003eBMS Controller\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan face=\"trebuchet ms, lucida grande, lucida sans unicode, lucida sans, tahoma, sans-serif\"\u003eAnd the second one to be used with\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003eany Modbus Display\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan face=\"trebuchet ms, lucida grande, lucida sans unicode, lucida sans, tahoma, sans-serif\"\u003e\u003cstrong\u003e\u003cspan\u003eTo set it up for the existing configuration is super easy just follow this video all you need is a screwdriver:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe height=\"315\" width=\"560\" src=\"https:\/\/www.youtube.com\/embed\/GPkjgTqDKIY\" frameborder=\"0\" allowfullscreen=\"\" allow=\"accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003eIt is so easy to programme it using our iSMA Tool. You do not need any previous experience or specialized training to be able to use it.¬†\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1144\/2302\/files\/iSMAFCU_large.gif?v=1549976290\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-FCU\/\" target=\"_blank\" title=\"Documentation \u0026amp; Downloads for iSMA-B-FCU-HL\" rel=\"noopener\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-FCU-HL style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-FCU-HL\" href=\"https:\/\/support.innon.com\/%20iSMA\/iSMA-B-FCU\/\"\u003e \u003c\/a\u003e\u003c\/p\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37322086711451,"sku":"iSMA-B-FCU-HL","price":239.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/iSMA-B-FCU-HL-600x600.png?v=1737466999"},{"product_id":"isma-b-lp-hc","title":"iSMA-B-LP-HC","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eiSMA-B-HC\u003c\/strong\u003e¬†is a room unit with \u003cstrong\u003e2.3‚Äù LCD\u003c\/strong\u003e display and four function buttons. Additionally, the room unit has the built-in temperature sensor and the humidity and CO\u003csub\u003e2\u003c\/sub\u003esensors.\u003c\/p\u003e\n\u003cp\u003eiSMA-B-LP-HC is powered with 24 V AC\/DC and has the built-in ¬†RS485 port (\u003cstrong\u003eModbus RTU\/ASCII\u003c\/strong\u003e). Use of open communication protocol allows to connect the room unit with any controller supports Modbus RTU\/ASCII. Together with \u003ca href=\"https:\/\/www.innon.co.uk\/search?type=product\u0026amp;q=isma-b-fcu\" title=\"iSMA-B-FCU controllers\"\u003eiSMA-B-FCU \u003c\/a\u003econtroller, the room unit allows to change the basic parameters such as: temperature setpoint, fan speed, FCU mode and others.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThanks to built-in USB port, there is possibility to firmware update and room unit configuration without the necessity of power supply. iSMA-B-LP-HC has the modern design and is available in different colours (white is basic) on client request.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-LP\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-LP-HC\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-LP-HC style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-LP-HC\" href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-LP\/\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37322091987099,"sku":"iSMA-B-LP-HC","price":514.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/iSMA-B-LP_a62e1a89-fa43-46ef-b097-233d6f756bde.png?v=1737466996"},{"product_id":"isma-b-lp-h","title":"iSMA-B-LP-H","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eiSMA-B-LP-H\u003c\/strong\u003e is a room unit with \u003cstrong\u003e2.3‚Äù LCD\u003c\/strong\u003e display and four function buttons. Additionally, the room unit has the built-in temperature sensor and the humidity¬†sensor.\u003c\/p\u003e\n\u003cp\u003eiSMA-B-LP-H is powered with 24 V AC\/DC and has the built-in ¬†RS485 port (\u003cstrong\u003eModbus RTU\/ASCII\u003c\/strong\u003e). Use of open communication protocol allows to connect the room unit with any controller supports Modbus RTU\/ASCII. Together with \u003ca href=\"https:\/\/www.innon.co.uk\/search?type=product\u0026amp;q=isma-b-fcu\" title=\"iSMA-B-FCU controllers\"\u003eiSMA-B-FCU \u003c\/a\u003econtroller, the room unit allows to change the basic parameters such as: temperature setpoint, fan speed, FCU mode and others.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThanks to built-in USB port, there is possibility to firmware update and room unit configuration without the necessity of power supply. iSMA-B-LP-H has the modern design and is available in different colours (white is basic) on client request.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\n\u003ca href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-LP\/\" target=\"_blank\" title=\"Documentation \u0026amp; Downloads for iSMA-B-LP-H\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-LP-H style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-LP-H\" href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-LP\/\"\u003e \u003c\/a\u003e\u003c\/script\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37322092347547,"sku":"iSMA-B-LP-H","price":208.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/iSMA-B-LP_d502a027-75b3-4445-89eb-6af927fcc8df.png?v=1737466995"},{"product_id":"isma-b-lp","title":"iSMA-B-LP","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eiSMA-B-LP\u003c\/strong\u003e is a room unit with \u003cstrong\u003e2.3‚Äù LCD\u003c\/strong\u003e display and four function buttons. Additionally, the room unit has the built-in temperature sensor and optionally the humidity and CO\u003csub\u003e2\u003c\/sub\u003esensors.\u003c\/p\u003e\n\u003cp\u003eiSMA-B-LP is powered with 24 V AC\/DC and has the built-in ¬†RS485 port (\u003cstrong\u003eModbus RTU\/ASCII\u003c\/strong\u003e). Use of open communication protocol allows to connect the room unit with any controller supports Modbus RTU\/ASCII. Together with \u003ca href=\"https:\/\/www.innon.co.uk\/search?type=product\u0026amp;q=isma-b-fcu\" title=\"iSMA-B-FCU controllers\"\u003eiSMA-B-FCU \u003c\/a\u003econtroller, the room unit allows to change the basic parameters such as: temperature setpoint, fan speed, FCU mode and others.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThanks to built-in USB port, there is possibility to firmware update and room unit configuration without the necessity of power supply. iSMA-B-LP has the modern design and is available in different colours (white is basic) on client request.\u003c\/span\u003e\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-LP\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-LP\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-LP style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-LP\" href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-LP\/\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37322092970139,"sku":"iSMA-B-LP","price":108.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-B-LP-600x600_png.png?v=1737466994"},{"product_id":"isma-b-fcu-hh","title":"iSMA-B-FCU-HH","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan face=\"trebuchet ms, lucida grande, lucida sans unicode, lucida sans, tahoma, sans-serif\" style=\"font-family: 'trebuchet ms', 'lucida grande', 'lucida sans unicode', 'lucida sans', tahoma, sans-serif;\"\u003e\u003cspan\u003eThis fan coil controller¬†\u003c\/span\u003eis designed to¬†remove the current frustration with available products. It has the best of everything from ease of use to flexibility and price. Here are the top 6 reasons why you would choose this Fan Coil Controller for your next project.\u003cbr\u003e\u003cbr\u003e1. It comes pre-loaded with software templates\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003ecovering over 95% of requirements\u003c\/strong\u003e. And even if you have to change something changes are minimal.\u003cbr\u003e\u003cbr\u003e2. It is fully programmable with our\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003eiSMA Tool,\u003c\/strong\u003e\u003cspan\u003e¬†\u003c\/span\u003eand you do not need any previous experience or specialised training.\u003cbr\u003e\u003cbr\u003e3. It has the most\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003egenerous IO\u003c\/strong\u003e:¬†4 Universal \/ Special Inputs, 4 Digital Inputs, 3 Analog Outputs, three fan speed relays, relay for the electric heater, relay for electric cooler, 2 Triac Outputs for heating and cooling valves and\u003cbr\u003e\u003cbr\u003e4. It¬†supports a wide range of Universal Inputs sensors, and by default, it\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003ecan read any 10K3 sensors.\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e5. It has¬†a¬†builtin 24 Volt transformer which can\u003cspan\u003e¬†\u003c\/span\u003epower most actuator valves in the market.\u003cbr\u003e\u003cbr\u003e6. It has two communication ports:\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan face=\"trebuchet ms, lucida grande, lucida sans unicode, lucida sans, tahoma, sans-serif\" style=\"font-family: 'trebuchet ms', 'lucida grande', 'lucida sans unicode', 'lucida sans', tahoma, sans-serif;\"\u003eOne to be used with\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003eany Modus or\u003cspan\u003e¬†\u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003eBACnet\u003c\/strong\u003e\u003cstrong\u003e\u003cspan\u003e¬†\u003c\/span\u003eBMS Controller\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan face=\"trebuchet ms, lucida grande, lucida sans unicode, lucida sans, tahoma, sans-serif\" style=\"font-family: 'trebuchet ms', 'lucida grande', 'lucida sans unicode', 'lucida sans', tahoma, sans-serif;\"\u003eAnd the second one to be used with\u003cspan\u003e¬†\u003c\/span\u003e\u003cstrong\u003eany Modbus Display\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTo set it up for the existing configuration is super easy just follow this video all you need is a screwdriver:\u003c\/p\u003e\n\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/GPkjgTqDKIY\" width=\"560\" height=\"315\" allow=\"accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen=\"\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003eIt is so easy to programme it using our iSMA Tool. You do not need any previous experience or specialized training to be able to use it.¬†\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1144\/2302\/files\/iSMAFCU_large.gif?v=1549976290\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e‚Ä¢ Preloaded universal application\u003c\/span\u003e\u003cbr\u003e‚Ä¢ Support 2-pipe or 4-pipe system\u003cbr\u003e‚Ä¢ Adjust application by dedicated DIP-switch\u003cbr\u003e‚Ä¢ Addressing from 0 to 255 by DIP-switch\u003cbr\u003e‚Ä¢ Sedona Framework 1.2 support\u003cbr\u003e‚Ä¢ Programming in real-time\u003cbr\u003e‚Ä¢ Built-in 18 Inputs\/Outputs\u003cbr\u003e‚Ä¢ Fast processor with ARM core\u003cbr\u003e‚Ä¢ Modbus ASCII\/RTU or BACnet MSTP\u003cbr\u003e‚Ä¢ 2 x RJ12 for connecting wall panels, external devices communicating in Modbus\u003cbr\u003e‚Ä¢ Built-in 24 V AC for an external equipment (version 230 V AC).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e\u003cbr\u003e4x Special Input - voltage, resistance, dry contact\u003cbr\u003e4x Digital Input ‚Äì dry contact Outputs\u003cbr\u003e3x Digital Output 6 A (Fan Speed)\u003cbr\u003e1x Digital Output 10 A (electric heater)\u003cbr\u003e1x Digital Output 6 A (cooling actuator)\u003cbr\u003e2x Triac 0,5 A @ 230 V AC or 0,5 A\/0,3 A* @ 24 V AC (heating and cooling, actuators)\u003cbr\u003e3x Analog Outputs 0-10 V DC (heating, cooling actuators and Fan Speed)\u003cbr\u003e\u003cstrong\u003ePlatform\u003c\/strong\u003e\u003cbr\u003eARM Cortex-M4\u003cbr\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003cbr\u003e230 V AC or 24 V AC\u003cbr\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003cbr\u003eInterface RS485 half duplex\u003cbr\u003eUp to 128 devices on the bus\u003cbr\u003eProtocols: Modbus or BACnet\u003cbr\u003eBaud rate: 4800 to 115200 bps\u003cbr\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003cbr\u003eDimension: 123,6x136,6x54,5 mm, (123,6x171,2x54,9 mm) with plastic cover for terminals\u003cbr\u003eConstruction: plastic, self-extinguishing (PC\/ABS)\u003cbr\u003eDIN rail mounting DIN (DIN EN 50022 norm)\u003cbr\u003eCooling: internal air circulation\u003cbr\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003cbr\u003eOperating temperature: -10¬∞C to 50¬∞C\u003cbr\u003eStorage temperature: -40¬∞C to 85¬∞C\u003cbr\u003eRelative humidity: 5% to 95%, no condensation\u003cbr\u003eIngress Protection Rating: IP40 ‚Äì for indoor installation¬†\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/support.innon.com\/iSMA\/iSMA-B-FCU\/\" target=\"_blank\" title=\"Documentation \u0026amp; Downloads for iSMA-B-FCU-HH\" rel=\"noopener\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-FCU-HH style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-FCU-HH\" href=\"https:\/\/support.innon.com\/%20iSMA\/iSMA-B-FCU\/\"\u003e \u003c\/a\u003e\u003c\/p\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37322093297819,"sku":"iSMA-B-FCU-HH","price":227.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/iSMA-B-FCU-HH-600x600.png?v=1737466993"},{"product_id":"black-pear-mx-range-for-mitsubishi-electric-air-conditioning-bacnet","title":"Black Pear MX-range for Mitsubishi Electric Air Conditioning Bacnet","description":"\u003cdiv id=\"wb_Image1\"\u003e\u003c\/div\u003e\n\u003cdiv id=\"wb_Text1\"\u003e\n\u003cdiv\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eOur MX range of Mitsubishi electric HVAC interfaces have evolved from the Procon MOD-IP\/50 and Procon BAC-IP\/50 which we've manufactured for many years. These are now available direct or through our distributors and are priced attractively. With many years of proven service in the market we are happy to supply the product direct due to high demand.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eOur MX range is everything that people are used too, and rely on.\u003c\/span\u003e\u003c\/div\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"https:\/\/support.innon.com\/BlackPear\/\" title=\"Documentation \u0026amp; Downloads for Black Pear MX-range for Mitsubishi Electric Air Conditioning Bacnet\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for Black Pear MX-range for Mitsubishi Electric Air Conditioning Bacnet  style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for Black Pear MX-range for Mitsubishi Electric Air Conditioning Bacnet\" href=\"https:\/\/support.innon.com\/BlackPear\/\"\u003e \u003c\/a\u003e\n\u003c\/div\u003e","brand":"Microtrol","offers":[{"title":"Default Title","offer_id":37322097590427,"sku":"MXB-50","price":2365.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/MM-A20_5ce9aa5b-7737-4a27-ba4b-e668e6ea1838.png?v=1737466988"},{"product_id":"isma-b-4to-h-ip","title":"iSMA-B-4TO-H-IP","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003eMINI modules have been designed to complement the MIX series. Depending on the project needs, one of 7 different MINI can be chosen, all inputs and outputs are unified among our products. One feature that makes these two product groups different is hand operating switches, in some applications, it is required. Moreover, all I\/O modules have \u003c\/span\u003e\u003cstrong\u003eBTL, CE \u003c\/strong\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cstrong\u003eUL \u003c\/strong\u003e\u003cspan\u003ecertificates.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eLike in the case of the MIX modules IP (1x Ethernet), MINI are factory-equipped with the most popular open communication protocols Modbus (TCP\/IP) and BACnet (IP), which are selected using DIP switches. Rotary switches are used to set the module address, which facilitates and accelerates the process of commissioning the system. Built-in mini USB allows for the initial configuration of the unit without external power supply.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eMINI I\/O Modules with Ethernet have built-in Modbus Gateway TCP\/IP to Modbus ASCII\/RTU, enabling you to connect additional modules\/devices that communicate via Modbus RS485.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eiSMA-B-4TO-H-IP is one of the most innovative IO Modules  and easy to setup. The module has 4xTO (Triac Outputs). TO can direct control 24-230 V AC voltage with max. 0,5 A load. The modules are factory-equipped with the two most popular open communication protocols: Modbus TCP\/IP and BACnet IP, which are selected using DIP switches. Can be hand operated and is suitable for faster switching and longer lifetime.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis module is fully compatible with any Modbus or Bacnet system including the following: Tridium Jace3, Jace6, Jace8000 Compatible, Trend IQ3, IQ4 Bacnet IP Compatible, Siemens PX range, Cylon Bacnet controllers, Schneider Electric StruxureWare Bacnet controllers, OSS NeOSS building management controller, Priva Blue ID, Distech EC Bos, DELL EDGE GATEWAY 5000, Compatible with any Honeywell Centraline Hawk, Delta Controls Compatible IO Modules\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInputs \u0026amp; Outputs:\u003c\/strong\u003e\u003cbr\u003e4x Triac Outputs (4TO)\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTriac outputs: 0,5 A @ 24 V AC, 0,5 A @ 230 V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlatform\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCortex-M3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInterface RS485 half duplex\u003c\/li\u003e\n\u003cli\u003e1 x Fast Ethernet\u003c\/li\u003e\n\u003cli\u003eUp to 99 devices on the bus\u003c\/li\u003e\n\u003cli\u003eProtocols: Modbus or BACnet\u003c\/li\u003e\n\u003cli\u003eBaud rate: 2400 to 115200 bps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e24 V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDimension: 35x110x62 mm\u003c\/li\u003e\n\u003cli\u003eConstruction: plastic, self-extinguishing (PC\/ABS)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting (DIN EN 50022 norm)\u003c\/li\u003e\n\u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironments\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature: -10 C to 50 C\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40 C to 85 C\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 5 to 95%, no condensation\u003c\/li\u003e\n\u003cli\u003eIngress Protection Rating: IP40‚ for indoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e Do you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MINI\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-4TO-H-IP\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" alt=\"Documentation \u0026amp; Downloads for iSMA-B-4TO-H-IP\" style=\"float: none;\"\u003e\u003c\/a\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MINI\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-4TO-H-IP\" target=\"_blank\"\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eIn the \u003ca href=\"http:\/\/support.innon.com\/\" target=\"_blank\"\u003eDOWNLOAD\u003c\/a\u003e session you can find: \u003cbr\u003eThe ISMA driver for Niagara, which contains the ISMA device Palette \u003cbr\u003eISMA configurator which is needed for updating firmware and configure modules\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eFor any help please contact our support \u003ca href=\"https:\/\/innon.myshopify.com\/pages\/contact-support\" title=\"Contact Innon Support\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37322108272795,"sku":"iSMA-B-4TO-H-IP","price":351.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-B-Mini-4TO-H-IP-600x600.png?v=1737466980"},{"product_id":"isma-b-4to-h","title":"iSMA-B-4TO-H","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\nThe module has¬†\u003cstrong\u003e4xTO\u003c\/strong\u003e (Triac Outputs). TO can direct control 24-230 V AC voltage with max. 0,5 A load.Suitable for faster switching and longer lifetime. Can be hand operated. \u003cbr\u003eThe module is factory-equipped with the two most popular open communication protocols: \u003cstrong\u003eModbus¬†ASCII\/RTU\u003c\/strong\u003e and¬†\u003cstrong\u003eBACnet¬†MSTP\u003c\/strong\u003e, which are selected using DIP switches. \u003cbr\u003eAddressing the modules is via rotary switches, which facilitates and accelerates the process of commissioning the system.\n\u003cp\u003eBuilt-in mini USB allows for initial configuration of the unit without power supply.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis module is fully compatible with any Modbus or Bacnet system including the following:¬†\u003c\/span\u003e\u003ca title=\"TRIDIUM IO MODULES\" href=\"https:\/\/www.innon.co.uk\/collections\/tridium-io-modules\" target=\"_blank\"\u003eTridium Jace3, Jace6, Jace8000¬†Compatible\u003c\/a\u003e\u003cspan\u003e,¬†\u003c\/span\u003e\u003ca title=\"Trend BEMS Compatible IO Modules\" href=\"https:\/\/www.innon.co.uk\/collections\/trend-io-modules\" target=\"_blank\"\u003eTrend IQ3, IQ4 Bacnet IP¬†Compatible\u003c\/a\u003e\u003cspan\u003e,¬†\u003c\/span\u003e\u003ca title=\"Siemens Bacnet IO Modules\" href=\"https:\/\/www.innon.co.uk\/collections\/siemens-io-modules\" target=\"_blank\"\u003eSiemens PX range\u003c\/a\u003e\u003cspan\u003e,¬†\u003c\/span\u003e\u003ca title=\"Cylon Bacnet IO Modules\" href=\"https:\/\/www.innon.co.uk\/collections\/cylon-bacnet-io-modules\"\u003eCylon Bacnet controllers\u003c\/a\u003e\u003cspan\u003e,¬†\u003c\/span\u003e\u003ca title=\"SCHNEIDER BACNET IO MODULES\" href=\"https:\/\/www.innon.co.uk\/collections\/schneider-bacnet-io-modules\" target=\"_blank\"\u003eSchneider Electric StruxureWare Bacnet controllers\u003c\/a\u003e\u003cspan\u003e,¬†\u003c\/span\u003e\u003ca title=\"OSS BACNET IP IO MODULES\" href=\"https:\/\/www.innon.co.uk\/collections\/oss-bacnet-ip-io-modules\" target=\"_blank\"\u003eOSS NeOSS building management controller\u003c\/a\u003e\u003cspan\u003e,¬†\u003c\/span\u003e\u003ca title=\"PRIVA BLUE ID BACNET IP IO MODULES\" href=\"https:\/\/www.innon.co.uk\/collections\/priva-blue-id-bacnet-ip-io-modules\" target=\"_blank\"\u003ePriva Blue ID\u003c\/a\u003e\u003cspan\u003e,¬†\u003c\/span\u003e\u003cspan data-sheets-value='{\"1\":2,\"2\":\"Distech\"}' data-sheets-userformat='{\"2\":17153,\"3\":{\"1\":0},\"11\":4,\"12\":0,\"17\":1}'\u003e\u003ca title=\"DISTECH IO MODULES\" href=\"https:\/\/www.innon.co.uk\/collections\/distech-io-modules\"\u003eDistech EC Bos\u003c\/a\u003e,¬†\u003ca title=\"DELL EDGE GATEWAY 5000 IO MODULES\" href=\"https:\/\/www.innon.co.uk\/collections\/dell-edge-gateway-5000-io-modules\" target=\"_blank\"\u003eDELL EDGE GATEWAY 5000\u003c\/a\u003e,¬†\u003ca title=\"HONEYWELL CENTRALINE IO MODULES\" href=\"https:\/\/www.innon.co.uk\/collections\/honeywell-centraline-io-modules\"\u003eCompatible with any Honeywell Centraline Hawk\u003c\/a\u003e,¬†\u003ca title=\"DELTA CONTROLS BACNET IP IO MODULES\" href=\"https:\/\/www.innon.co.uk\/collections\/delta-controls-bacnet-ip-io-modules\"\u003eDelta Controls Compatible IO Modules\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cstrong\u003eInputs \u0026amp; Outputs: \u003c\/strong\u003e \u003cbr\u003e4x Triac Outputs (4TO)\n\u003cul\u003e\n\u003cli\u003eTriac¬†outputs:¬† 0,5 A @ 24 V AC, 0,5 A @ 230 V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003ePlatform\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eCortex-M3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eCommunication\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eInterface RS485 half duplex\u003c\/li\u003e\n\u003cli\u003eUp to 99 devices on the bus\u003c\/li\u003e\n\u003cli\u003eProtocols: Modbus or BACnet\u003c\/li\u003e\n\u003cli\u003eBaud rate: 2400 to 115200 bps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003ePower supply\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e24 V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eHousing\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eDimension: 35x110x62 mm\u003c\/li\u003e\n\u003cli\u003eConstruction: plastic, self-extinguishing (PC\/ABS)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting (DIN EN 50022 norm)\u003c\/li\u003e\n\u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eEnvironments\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature: -10¬∞C to 50¬∞C\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40¬∞C to 85¬∞C\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 5 to 95%, no condensation\u003c\/li\u003e\n\u003cli\u003eIngress Protection Rating: IP40 ‚Äì for indoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e \u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MINI\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-4TO-H\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" alt=\"Documentation \u0026amp; Downloads for iSMA-B-4TO-H\" style=\"float: none;\"\u003e\u003c\/a\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MINI\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-4TO-H\" target=\"_blank\"\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003eIn the \u003ca href=\"http:\/\/support.innon.com\/\" target=\"_blank\"\u003eDOWNLOAD\u003c\/a\u003e session you can find: \u003cbr\u003eThe ISMA driver for Niagara, which contains the ISMA device Palette \u003cbr\u003eISMA configurator which is needed for updating firmware and configure modules\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eFor any help please contact our support \u003ca href=\"https:\/\/innon.myshopify.com\/pages\/contact-support\" title=\"Contact Innon Support\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37322108731547,"sku":"iSMA-B-4TO-H","price":276.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-B-Mini-4TO-H-600x600.png?v=1737466979"},{"product_id":"mitsubishi-ac-bms-gateway-1","title":"Mitsubishi AC BMS Gateway","description":"\u003ch5\u003e\u003cb\u003eAbout the Product\u003c\/b\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cb\u003eMitsubishi¬†Air Conditioning Interface Gateway \u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eOur range of Black Pear Mitsubishi electric HVAC interfaces is the most versatile on the market, connecting directly to the 2-wire HVAC bus. The integrated LCD display provides an engineer‚Äôs interface for local control, removing the need for a central controller and separate interface. The result saves time, space and most of all money! Commissioning is made simple with free USB based configuration software. The units will operate on systems with or without a central controller and supports Modbus, BACnet or Trend protocols. Each Black Pear will support 50 x FCU units.\u003cspan style=\"font-family: Verdana;\" face=\"Verdana\"\u003e¬† \u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Info\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAir conditioner connection: Mitsubishi 2-wire M-Net communication bus\u003cbr\u003eCommunications platforms: Ethernet,¬†RS232,¬†RS485,¬†2-wire Network Bus\u003cbr\u003eControl: Set point,¬†Return Air,¬†Mode,¬†Vane position,¬†Fan speed,¬†Inhibit,¬†Error Code,¬†On\/off,¬†Air Direction\u003cbr\u003eDimensions: 211mm x 118 mm\u003cbr\u003ePower requirement: 24 a.c 5VA\u003cbr\u003eModels Available :\u003c\/p\u003e\n\u003cp\u003eBP-STD-MM-50 -¬†¬†¬† Modbus¬†\u003cbr\u003eBP-STD-MM-50D -¬† Modbus with display\u003cbr\u003eBP-STD-MB-50 -¬†¬†¬†¬† BACnet\u003cbr\u003eBP-STD-MB-50D -¬† BACnet with¬† display¬†\u003cbr\u003eBP-STD-MT-50 -¬†¬†¬†¬† Trend\u003cbr\u003eBP-STD-MT-50D -¬† Trend with display\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"https:\/\/support.innon.com\/BlackPear\/\" title=\"Documentation \u0026amp; Downloads for Mitsubishi AC BMS Gateway\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for Mitsubishi AC BMS Gateway  style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for Mitsubishi AC BMS Gateway\" href=\"https:\/\/support.innon.com\/BlackPear\/\"\u003e \u003c\/a\u003e","brand":"Microtrol","offers":[{"title":"BP-STD-MM-50","offer_id":37322110697627,"sku":"MM-50","price":2535.0,"currency_code":"EUR","in_stock":true},{"title":"BP-STD-MB-50","offer_id":37322110894235,"sku":"MB-50","price":2898.0,"currency_code":"EUR","in_stock":true},{"title":"BP-STD-MT-50","offer_id":37322110992539,"sku":"MT-50","price":2535.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ToshibaACBMSGateway1_2446cb20-2596-4681-b1a5-7ff58a809601.png?v=1737466978"},{"product_id":"toshiba-ac-bms-gateway","title":"Toshiba AC BMS Gateway","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003e\u003cb\u003eToshiba¬†Air Conditioning Interface Gateway \u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eOur range of Black Pear Toshiba electric HVAC interfaces is the most versatile on the market, connecting directly to the 2-wire HVAC bus. The integrated LCD display provides an engineer‚Äôs interface for local control, removing the need for a central controller and separate interface. The result saves time, space and most of all money! Commissioning is made simple with free USB based configuration software. The units will operate on systems with or without a central controller and supports Modbus, BACnet or Trend protocols. Each Black Pear will support 50 x FCU units.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eProtocols Supported:\u003c\/b\u003e Modbus RTU,¬†Modbus\/TCP,¬†BACnet\/IP,¬†Trend via CNC\u003cbr\u003e \u003cb\u003eAir conditioner connection:\u003c\/b\u003e¬†Toshiba 2-wire communication bus\u003cbr\u003e \u003cb\u003eCommunications platforms:\u003c\/b\u003e Ethernet,¬†RS232,¬†RS485,¬†2-wire Network Bus\u003cbr\u003e \u003cb\u003eControl:\u003c\/b\u003e Set point,¬†Return Air,¬†Mode,¬†Vane position,¬†Fan speed,¬†Inhibit,¬†Error Code,¬†On\/off,¬†Air Direction\u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 211mm x 118 mm \u003cbr\u003e\u003cb\u003eBacklit graphic display:\u003c\/b\u003e¬†62mm x 62mm and navigational buttons *(Available on D models only) \u003cbr\u003e \u003cb\u003ePower requirement:\u003c\/b\u003e 24 a.c 5VA\u003c\/p\u003e\n\u003cp\u003eModels Available:¬†\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBP-STD-TM-64 - Modbus\u003c\/li\u003e\n\u003cli\u003eBP-STD-TM-64D - Modbus with display\u003c\/li\u003e\n\u003cli\u003eBP-STD-TB-64 - BACnet\u003c\/li\u003e\n\u003cli\u003eBP-STD-TB-64D - BACnet with display\u003c\/li\u003e\n\u003cli\u003eBP-STD-TT-64 - Trend\u003c\/li\u003e\n\u003cli\u003eBP-STD-TT-64D - Trend with display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"https:\/\/support.innon.com\/BlackPear\/Toshiba\/\" title=\"Documentation \u0026amp; Downloads for Toshiba AC BMS Gateway\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for Toshiba AC BMS Gateway  style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for Toshiba AC BMS Gateway\" href=\"https:\/\/support.innon.com\/BlackPear\/Toshiba\/\"\u003e \u003c\/a\u003e","brand":"Microtrol","offers":[{"title":"BP-STD-TM-64","offer_id":37322115776667,"sku":"TM-64","price":2535.0,"currency_code":"EUR","in_stock":true},{"title":"BP-STD-TB-64","offer_id":37322115842203,"sku":"TB-64","price":2898.0,"currency_code":"EUR","in_stock":true},{"title":"BP-STD-TT-64","offer_id":37322115940507,"sku":"TT-64","price":2535.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ToshibaACBMSGateway1.png?v=1737466976"},{"product_id":"panasonic-ac-bms-gateway","title":"Panasonic AC BMS Gateway","description":"\u003ch5\u003eAbout the Product\u003c\/h5\u003e\n\u003cp\u003e\u003cb\u003ePanasonic¬†Air Conditioning Interface Gateway\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eOur¬† range of Black Pear Panasonic HVAC interfaces is the most versatile on the market, connecting directly to the 2-wire HVAC bus. The integrated LCD display provides an engineer‚Äôs interface for local control, removing the need for a central controller and separate interface. The result saves time, space and most of all money! Commissioning is made simple with free USB based configuration software. The units will operate on systems with or without a central controller and supports Modbus, BACnet or Trend protocols. Each Black Pear will support 64 x FCU units.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eProtocols Supported:\u003c\/b\u003e Modbus RTU,¬†Modbus\/TCP,¬†BACnet\/IP,¬†Trend via CNC\u003cbr\u003e \u003cb\u003eAir conditioner connection:\u003c\/b\u003e¬†Panasonic 2-wire communication bus \u003cbr\u003e\u003cb\u003eCommunications platforms:\u003c\/b\u003e Ethernet,¬†RS232,¬†RS485,¬†2-wire Network Bus\u003cbr\u003e \u003cb\u003eControl:\u003c\/b\u003e Set point,¬†Return Air,¬†Mode,¬†Vane position,¬†Fan speed,¬†Inhibit,¬†Error Code,¬†On\/off,¬†Air Direction \u003cbr\u003e \u003cb\u003eDimensions:\u003c\/b\u003e 211mm x 118 mm \u003cbr\u003e\u003cb\u003eBacklit graphic display:\u003c\/b\u003e¬†62mm x 62mm and navigational buttons* (Available on D models only) \u003cbr\u003e \u003cb\u003ePower requirement:\u003c\/b\u003e 24 a.c 5VA \u003cbr\u003e \u003cb\u003eModels Available:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePBP-STD-PM-64 - Modbus\u003c\/li\u003e\n\u003cli\u003eBP-STD-PM-64D - Modbus with display ¬†¬†\u003c\/li\u003e\n\u003cli\u003eBP-STD-PB-64 - BACnet\u003c\/li\u003e\n\u003cli\u003eBP-STD-PB-64D - BACnet with display\u003c\/li\u003e\n\u003cli\u003eBP-STD-PT-64 - Trend\u003c\/li\u003e\n\u003cli\u003eBP-STD-PT-64D - Trend with display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"https:\/\/support.innon.com\/BlackPear\/\" title=\"Documentation \u0026amp; Downloads for Panasonic AC BMS Gateway\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for Panasonic AC BMS Gateway  style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for Panasonic AC BMS Gateway\" href=\"https:\/\/support.innon.com\/BlackPear\/\"\u003e \u003c\/a\u003e","brand":"Microtrol","offers":[{"title":"BP-STD-PM-64","offer_id":37322118496411,"sku":"PM-64","price":2535.0,"currency_code":"EUR","in_stock":true},{"title":"BP-STD-PB-64","offer_id":37322118561947,"sku":"PB-64","price":2898.0,"currency_code":"EUR","in_stock":true},{"title":"BP-STD-PT-64","offer_id":37322118627483,"sku":"PT-64","price":2535.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ToshibaACBMSGateway1_84373e54-d0fd-4f26-ba11-c4e2f70269f5.png?v=1737466975"},{"product_id":"daikin-ac-bms-gateway","title":"Daikin AC BMS Gateway","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003e\u003cb\u003eDaikin Air Conditioning Interface Gateway \u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThese Daikin HVAC interfaces are the most versatile on the market, connecting directly to the 2-wire HVAC bus. The integrated LCD display provides an engineer‚Äôs interface for local control, removing the need for a central controller and separate interface. The result saves time, space and most of all money! Commissioning is made simple with free USB based configuration software. The units will operate on systems with or without a central controller and supports Modbus, BACnet or Trend protocols. Each Black Pear will support 64 x FCU units.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProtocols Supported:\u003c\/strong\u003e Modbus RTU,¬†Modbus\/TCP,¬†BACnet\/IP,¬†Trend via CNC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAir conditioner connection:\u003c\/strong\u003e Daikin 2-wire communication bus\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommunications platforms:\u003c\/strong\u003e Ethernet,¬†RS232,¬†RS485,¬†2-wire Network Bus\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eControl:\u003c\/strong\u003e Set point,¬†Return Air,¬†Mode,¬†Vane position,¬†Fan speed,¬†Inhibit,¬†Error Code,¬†On\/off,¬†Air Direction\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 211mm x 118 mm Backlit graphic display:62mm x 62mm and navigational buttons (Available on D models only)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower requirement:\u003c\/strong\u003e 24 a.c 5VA\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModels Available:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBP-STD-DM-64 - Modbus ¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†\u003c\/p\u003e\n\u003cp\u003eBP-STD-DM-64D - Modbus with display ¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†\u003c\/p\u003e\n\u003cp\u003eBP-STD-DB-64 - BACnet ¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†\u003c\/p\u003e\n\u003cp\u003eBP-STD-DB-64D - BACnet with display ¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†\u003c\/p\u003e\n\u003cp\u003eBP-STD-DT-64 - Trend ¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†¬†\u003c\/p\u003e\n\u003cp\u003eBP-STD-DT-64D - Trend with display\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"https:\/\/support.innon.com\/BlackPear\/\" title=\"Documentation \u0026amp; Downloads for Daikin AC BMS Gateway\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for Daikin AC BMS Gateway  style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for Daikin AC BMS Gateway\" href=\"https:\/\/support.innon.com\/BlackPear\/\"\u003e \u003c\/a\u003e\n\u003c\/div\u003e","brand":"Microtrol","offers":[{"title":"BP-STD-DM-64","offer_id":37322120921243,"sku":"DM-64","price":2535.0,"currency_code":"EUR","in_stock":true},{"title":"BP-STD-DB-64","offer_id":37322120986779,"sku":"DB-64","price":2898.0,"currency_code":"EUR","in_stock":true},{"title":"BP-STD-DT-64","offer_id":37322121052315,"sku":"DT-64","price":2535.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ToshibaACBMSGateway1_53b2e085-f3f2-454e-9d54-caddfd8d8e0c.png?v=1737466973"},{"product_id":"isma-b-w0202","title":"iSMA-B-W0202","description":"\u003ch5\u003eAbout The Product\u003c\/h5\u003e\n\u003cp\u003eThis wireless modbus IO Module is ideal for gas, electricity and¬†water¬†metering applications. Suitable for lighting control with built-in logic achieving very short response times. Helps distribute IO modules around the building and integrate remote Modbus RS485 devices.\u003c\/p\u003e\n\u003cp\u003eKey facts:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe module does not require battery making it very low maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNo programming¬†of registers¬†or Master and Slave.¬†\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSolve the most complex projects with one part number,¬†easy to budget for.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIt achieves the¬†best possible wireless range of¬†300m in buildings by using the 868MHz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWe made it¬†flexible¬†so the¬†wireless¬†range can be extended by separating the network into different channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEach¬†ISMA-B-W0202 allows connection to other RS485 devices using the¬†onboard RS485 port¬†such as¬†\u003ca href=\"http:\/\/ib3.bislr.net\/m?s=innon\u0026amp;m=s_4ba24b84-a293-414b-bfad-6ec48406b846\u0026amp;u=e1jq4wvfdtfkag9p68v48gj65n142cj45mu32chk5mwm8hj15mwm4h1r8d148c1h6crmc\u0026amp;r2=d1u78w1u5wqq8bkkd5j6auv9cdnpyw35druk8bk3dxpjyt9hegqp6btn5xk32e34a5m64c2k6xp46e348h6n0rjq69q30y1pdgt44ebe9n55edvm6nc5mwtqch5n6y3pawv36jjre193et2kdru3cnjh89h34p9n6tj52mkhcrupevjp8hkk0chzegypgx3me1tjacu14mt4c99j8tvqexted5q6wvve5thpybkndcjk4hkge9qp8xb3ehtjacj6d5tpur9dc8pkgu96edmkud9k60v32d9r6guk6e1r68w3gc16e1mkuc1rcrt3gc1kccpkee3468pk8chg6rpkjt9k6wppat1j60r30eb16hj6ae8\u0026amp;n=3\" target=\"_blank\"\u003eISMA-B-8I\u003c\/a\u003e¬†\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMostly used in metering projects where cabling is expensive or not possible. This module helps integrate remote modbus meters and pick up pulse meters.\u003c\/p\u003e\n\u003cp\u003eW0202 has been built to allow extension of RS485 bus using wireless technology wherever use of network cable is impossible or no cost effective. Use of two W0202 allows to build the wireless ‚Äòbridge‚Äô for the RS485 by building wireless remote island (one or more) for devices communicate via Modbus RTU \/ ASCII\u003c\/p\u003e\n\u003ch3\u003e2xUniversal Inputs (2UI)\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan\u003eAll universal inputs have 16-bit resolution which support the following types of inputs:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature input support the following types of sensors: 10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1: accuracy ¬± 0,1¬∞C at 25¬∞C\u003c\/li\u003e\n\u003cli\u003eVoltage input 0-10VDC: input resistance 100kŒ© accuracy ¬±0,1% measurement resolution 3mV@12bit and 1mV@16bit\u003c\/li\u003e\n\u003cli\u003eCurrent input 0-20mA\u003c\/li\u003e\n\u003cli\u003eResistive input 0-1000kŒ©: measurement resolution for 20kŒ© load 20Œ©@12bit and 1Œ©@16bit\u003c\/li\u003e\n\u003cli\u003eDry contact input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e2xDigital Outputs (2DO)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRelay output (NO) max. 3A, 250 VAC\/30 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlatform\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCortex-M3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommunication\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInterface RS485 half duplex\u003c\/li\u003e\n\u003cli\u003eUp to 99 devices on the bus\u003c\/li\u003e\n\u003cli\u003eProtocols: MODBUS\u003c\/li\u003e\n\u003cli\u003eBaud rate: 2400 to 115200 bps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePower supply\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e24V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHousing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDimension: 17,5x110x62 mm.\u003c\/li\u003e\n\u003cli\u003eConstruction: plastic, self-extinguishing (PC\/ABS)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting (DIN EN 50022 norm)\u003c\/li\u003e\n\u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eEnvironments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature: -10¬∞C to 50¬∞C\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40¬∞C to 85¬∞C\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 5 to 95%, no condensation\u003c\/li\u003e\n\u003cli\u003eIngress Protection Rating: IP40 ‚Äì for indoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-W0202\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-W0202\/\" target=\"_blank\"\u003e\u003cimg style=\"float: none;\" alt=\"Documentation \u0026amp; Downloads for iSMA-B-W0202\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\"\u003e\u003c\/a\u003e \u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-W0202\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-W0202\/\" target=\"_blank\"\u003e \u003c\/a\u003e In the \u003ca href=\"http:\/\/support.innon.com\/\"\u003eDOWNLOAD\u003c\/a\u003e session you can find:\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe ISMA driver for Niagara, which contains the ISMA device Palette\u003c\/li\u003e\n\u003cli\u003eIsma configurator which is needed for updating firmware and configure modulesFor more information visit the manufacturer‚Äôs site:\u003cstrong\u003e\u003cspan class=\"Apple-converted-space\"\u003e¬†\u003c\/span\u003e\u003ca href=\"http:\/\/support.gc5.pl\/\" title=\"http:\/\/support.gc5.pl\/\" target=\"_blank\"\u003ehttp:\/\/support.gc5.pl\/\u003c\/a\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIn the \u003ca href=\"https:\/\/www.innon.co.uk\/pages\/isma-download\" target=\"_blank\"\u003eDOWNLOAD\u003c\/a\u003e session you can find: \u003cbr\u003eThe ISMA driver for Niagara, which contains the ISMA device Palette \u003cbr\u003eISMA configurator which is needed for updating firmware and configure modules\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eFor any help please contact our support \u003ca title=\"Contact Innon Support\" href=\"https:\/\/innon.myshopify.com\/pages\/contact-support\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37322122133659,"sku":"ISMA-B-W0202","price":330.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-B-W0202-600x600.png?v=1737466972"},{"product_id":"isma-b-wext5","title":"iSMA-B-WEXT5","description":"\u003ch5\u003e\u003cstrong\u003eAbout the product\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003eAn extension cable 5 meter length for wireless modules\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-W0202\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-W0202\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" alt=\"Documentation \u0026amp; Downloads for iSMA-B-W0202\" style=\"float: none;\"\u003e\u003c\/a\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-W0202\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-W0202\" target=\"_blank\"\u003e \u003c\/a\u003e\u003c\/p\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37322140942491,"sku":"iSMA-B-WEXT5","price":55.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/iSMA-B-WEXT2_23074242-60ea-445a-999c-5e27c04cc05e.png?v=1737466965"},{"product_id":"isma-b-wext2","title":"iSMA-B-WEXT2","description":"\u003ch5\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #666666; font-family: 'Open Sans', sans-serif; font-style: normal; font-variant: normal; letter-spacing: normal; line-height: 20px; text-align: start; text-indent: 0px; text-transform: none; white-space: normal; widows: 1; word-spacing: 0px; -webkit-text-stroke-width: 0px; float: none; background-color: #ffffff; display: inline !important;\"\u003eAbout the product\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #666666; font-family: 'Open Sans', sans-serif; font-size: 14px; font-style: normal; font-variant: normal; font-weight: normal; letter-spacing: normal; line-height: 20px; orphans: auto; text-align: start; text-indent: 0px; text-transform: none; white-space: normal; widows: 1; word-spacing: 0px; -webkit-text-stroke-width: 0px; display: inline !important; float: none; background-color: #ffffff;\"\u003eAn extension cable 2 meter length for wireless iSMA-B-W0202 modules\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-W0202\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-W0202\/\" target=\"_blank\"\u003e\u003cimg style=\"float: none;\" alt=\"Documentation \u0026amp; Downloads for iSMA-B-W0202\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\"\u003e\u003c\/a\u003e \u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-W0202\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-W0202\/\" target=\"_blank\"\u003e \u003c\/a\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37322141368475,"sku":"iSMA-B-WEXT2","price":42.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/iSMA-B-WEXT2.png?v=1737466965"},{"product_id":"isma-b-aac20-lcd-d","title":"iSMA-B-AAC20-LCD-D","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eAAC20 controller (iSMA-B-AAC20)¬†with \u003cstrong\u003einbuilt display and DALI\u003c\/strong\u003e is an advanced device to control building automation and HVAC systems. Use of SVM (Sedona Virtual Machine) allows you to finish the setup quickly and easily. It is ideal for smaller projects where you want to stay open protocol while keeping the development simple and the cost under budget.\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003eBig, fully programmable LCD can be used as simple user interface to allows local operation of system. The DALI Interface with¬†built-in power supply.\u003c\/p\u003e\n\u003cp\u003eWith the large number of inputs and outputs allows to integrate with other devices and sensors (AAC20 provides 8xUI, 4xDI, 4\/6xAO and 4xDO). Its fast processor allows to control of even very large objects. Built-in RS485 can be used to expand number of I\/O by connecting MINI or MIX series I\/O modules using Modbus ASCII\/RTU. In addition, to increase the versatility of the controller, it supports many open communications protocols like: BACnet, Modbus, SOX, DALI, M-Bus, 1-wire or oBIX (optional). AAC20 is mounted in a housing adapted for DIN rail mounting or directly on a panel. Separate, easy to remove connectors allow quick wiring without removing the entire module.\u003c\/p\u003e\n\u003cstrong\u003eInputs \u0026amp; Outputs\u003c\/strong\u003e\u003cbr\u003e8xUniversal Inputs (8UI)\u003cbr\u003eAll universal inputs have 16-bit resolution which support the following types of inputs:\n\u003cul\u003eTemperature input support the following types of sensors: 10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1, Pt1000, Ni1000\u003c\/ul\u003e\n\u003cb\u003eFor sensor Pt1000 and Ni1000 use only 16bit resolution\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage input 0-10VDC: input resistance 100kŒ© accuracy ¬±0,1% measurement resolution 3mV@12bit and 1mV@16bit\u003c\/li\u003e\n\u003cli\u003eCurrent input 0-20mA (external resistor 499Œ© required)\u003c\/li\u003e\n\u003cli\u003eResistive input 0-1000kŒ©: measurement resolution for 20kŒ© load 20Œ©@12bit and 1Œ©@16bit\u003c\/li\u003e\n\u003cli\u003eDry contact input\u003c\/li\u003e\n\u003c\/ul\u003e\n4 x Digital Inputs (4DI)\n\u003cul\u003e\n\u003cli\u003eDry contact inputs\u003c\/li\u003e\n\u003cli\u003eFast pulse counter up to 100Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n4\/6 x Analog Outputs (4\/6AO)\u003cbr\u003eAll analog outputs are equipped with 12-bit ADC provides10 mV resolution and accuracy less than ¬±0,5%. They support the following output types:\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eOutput 0-10V DC maximum load up to 20mA(5mA- AO6)\u003c\/li\u003e\n\u003cli\u003ePWM: 0,01Hz, 0,1Hz, 1Hz, 10Hz, 100Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\nAO5 and AO6 can only be used if 1-wire port is not in use, please notice for AO6 maximum current load is up to 5mA \u003cbr\u003e4 x Digital Outputs (4DO)\n\u003cul\u003e\n\u003cli\u003eRelay output (NO) max. 3A, 250 VAC\/30 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003ePlatform\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eARM Cortex-M4 204MHz\u003c\/li\u003e\n\u003cli\u003eARM Cortex-M0 204MHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eCommunication\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eInterface RS485 half duplex\u003c\/li\u003e\n\u003cli\u003eBaud rate: 2400 to 115200 bps\u003c\/li\u003e\n\u003cli\u003e2xEthernet with built in switch\u003c\/li\u003e\n\u003cli\u003e1-Wire Interface\u003c\/li\u003e\n\u003cli\u003eMicro SD card slot\u003c\/li\u003e\n\u003cli\u003eUSB Host Interface\u003c\/li\u003e\n\u003cli\u003eProtocols: Modbus, BACnet, 1-wire, oBIX\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003ePower supply\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e24V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eHousing\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eDimension: 106x110x62 mm.\u003c\/li\u003e\n\u003cli\u003eConstruction: plastic, self-extinguishing (PC\/ABS)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting (DIN EN 50022 norm)\u003c\/li\u003e\n\u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eEnvironments\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature: -10¬∞C to 50¬∞C\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40¬∞C to 85¬∞C\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 5 to 95%, no condensation\u003c\/li\u003e\n\u003cli\u003eIngress Protection Rating: IP40 ‚Äì for indoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-AAC20\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-AAC20-LCD-D\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-AAC20-LCD-D style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-AAC20-LCD-D\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-AAC20\/\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37322142220443,"sku":"iSMA-B-AAC20-LCD-D","price":1010.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/isma-aac20-lcd_699a4b5a-214c-4ea0-912d-3ed5a357633a.png?v=1737466964"},{"product_id":"isma-b-aac20-lcd","title":"iSMA-B-AAC20-LCD","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eAAC20 controller (iSMA-B-AAC20)¬†with inbuilt display is an advanced device to control building automation and HVAC systems. Use of SVM (Sedona Virtual Machine) allows you to finish the setup quickly and easily. It is ideal for smaller projects where you want to stay open protocol while keeping the development simple and the cost under budget.\u003c\/p\u003e\n\u003cp\u003eWith the large number of inputs and outputs allows to integrate with other devices and sensors (AAC20 provides 8xUI, 4xDI, 4\/6xAO and 4xDO). Its fast processor allows to control of even very large objects. Built-in RS485 can be used to expand number of I\/O by connecting MINI or MIX series I\/O modules using Modbus ASCII\/RTU. In addition, to increase the versatility of the controller, it supports many open communications protocols like: BACnet, Modbus, SOX, DALI, M-Bus, 1-wire or oBIX (optional). AAC20 is mounted in a housing adapted for DIN rail mounting or directly on a panel. Separate, easy to remove connectors allow quick wiring without removing the entire module.\u003c\/p\u003e\n\u003cstrong\u003eInputs \u0026amp; Outputs\u003c\/strong\u003e\u003cbr\u003e8xUniversal Inputs (8UI)\u003cbr\u003eAll universal inputs have 16-bit resolution which support the following types of inputs:\n\u003cul\u003e\n\u003cli\u003eTemperature input support the following types of sensors: 10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1, Pt1000, Ni1000\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cb\u003eFor sensor Pt1000 and Ni1000 use only 16bit resolution\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage input 0-10VDC: input resistance 100kŒ© accuracy ¬±0,1% measurement resolution 3mV@12bit and 1mV@16bit\u003c\/li\u003e\n\u003cli\u003eCurrent input 0-20mA (external resistor 499Œ© required)\u003c\/li\u003e\n\u003cli\u003eResistive input 0-1000kŒ©: measurement resolution for 20kŒ© load 20Œ©@12bit and 1Œ©@16bit\u003c\/li\u003e\n\u003cli\u003eDry contact input\u003c\/li\u003e\n\u003c\/ul\u003e\n4 x Digital Inputs (4DI)\n\u003cul\u003e\n\u003cli\u003eDry contact inputs\u003c\/li\u003e\n\u003cli\u003eFast pulse counter up to 100Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n4\/6 x Analog Outputs (4\/6AO)\u003cbr\u003eAll analog outputs are equipped with 12-bit ADC provides10 mV resolution and accuracy less than ¬±0,5%. They support the following output types:\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eOutput 0-10V DC maximum load up to 20mA(5mA- AO6)\u003c\/li\u003e\n\u003cli\u003ePWM: 0,01Hz, 0,1Hz, 1Hz, 10Hz, 100Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\nAO5 and AO6 can only be used if 1-wire port is not in use, please notice for AO6 maximum current load is up to 5mA \u003cbr\u003e4 x Digital Outputs (4DO)\n\u003cul\u003e\n\u003cli\u003eRelay output (NO) max. 3A, 250 VAC\/30 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003ePlatform\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eARM Cortex-M4 204MHz\u003c\/li\u003e\n\u003cli\u003eARM Cortex-M0 204MHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eCommunication\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eInterface RS485 half duplex\u003c\/li\u003e\n\u003cli\u003eBaud rate: 2400 to 115200 bps\u003c\/li\u003e\n\u003cli\u003e2xEthernet with built in switch\u003c\/li\u003e\n\u003cli\u003e1-Wire Interface\u003c\/li\u003e\n\u003cli\u003eMicro SD card slot\u003c\/li\u003e\n\u003cli\u003eUSB Host Interface\u003c\/li\u003e\n\u003cli\u003eProtocols: Modbus, BACnet, 1-wire, oBIX\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003ePower supply\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e24V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eHousing\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eDimension: 106x110x62 mm.\u003c\/li\u003e\n\u003cli\u003eConstruction: plastic, self-extinguishing (PC\/ABS)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting (DIN EN 50022 norm)\u003c\/li\u003e\n\u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eEnvironments\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature: -10¬∞C to 50¬∞C\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40¬∞C to 85¬∞C\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 5 to 95%, no condensation\u003c\/li\u003e\n\u003cli\u003eIngress Protection Rating: IP40 ‚Äì for indoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-AAC20\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-AAC20-LCD\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-AAC20-LCD style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-AAC20-LCD\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-AAC20\/\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37322142384283,"sku":"iSMA-B-AAC20-LCD","price":872.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/isma-b-aac20-lcd-600x600.png?v=1737466963"},{"product_id":"isma-b-aac20-d","title":"iSMA-B-AAC20-D","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eiSMA-B-AAC20-D controller is an advanced device to control building automation and HVAC systems with Dali Control. Use of SVM (Sedona Virtual Machine) allows you to finish the setup quickly and easily. It is ideal for smaller projects where you want to stay open protocol while keeping the development simple and the cost under budget. The controller has a DALI interface with built in power supply.\u003c\/p\u003e\n\u003cp\u003eWith the large number of inputs and outputs allows to integrate with other devices and sensors (AAC20 provides 8xUI, 4xDI, 4\/6xAO and 4xDO). Its fast processor allows to control of even very large objects. Built-in RS485 can be used to expand number of I\/O by connecting MINI or MIX series I\/O modules using Modbus ASCII\/RTU. In addition, to increase the versatility of the controller, it supports many open communications protocols like: BACnet, Modbus, SOX, DALI, M-Bus, 1-wire or oBIX (optional). AAC20 is mounted in a housing adapted for DIN rail mounting or directly on a panel. Separate, easy to remove connectors allow quick wiring without removing the entire module.\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eInputs \u0026amp; Outputs\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e8xUniversal Inputs (8UI)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eAll universal inputs have 16-bit resolution which support the following types of inputs:\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature input support the following types of sensors: 10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1, Pt1000, Ni1000\u003c\/li\u003e\n\u003c\/ul\u003e\nFor sensor Pt1000 and Ni1000 use only 16bit resolution\n\u003cul\u003e\n\u003cli\u003eVoltage input 0-10VDC: input resistance 100kŒ© accuracy ¬±0,1% measurement resolution 3mV@12bit and 1mV@16bit\u003c\/li\u003e\n\u003cli\u003eCurrent input 0-20mA (external resistor 499Œ© required)\u003c\/li\u003e\n\u003cli\u003eResistive input 0-1000kŒ©: measurement resolution for 20kŒ© load 20Œ©@12bit and 1Œ©@16bit\u003c\/li\u003e\n\u003cli\u003eDry contact input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan\u003e4 x Digital Inputs (4DI)\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eDry contact inputs\u003c\/li\u003e\n\u003cli\u003eFast pulse counter up to 100Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan\u003e4\/6 x Analog Outputs (4\/6AO)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eAll analog outputs are equipped with 12-bit ADC provides10 mV resolution and accuracy less than ¬±0,5%. They support the following output types:\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eOutput 0-10V DC maximum load up to 20mA(5mA- AO6)\u003c\/li\u003e\n\u003cli\u003ePWM: 0,01Hz, 0,1Hz, 1Hz, 10Hz, 100Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan\u003eAO5 and AO6 can only be used if 1-wire port is not in use, please notice for AO6 maximum current load is up to 5mA \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e4 x Digital Outputs (4DO)\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eRelay output (NO) max. 3A, 250 VAC\/30 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003ePlatform\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eARM Cortex-M4 204MHz\u003c\/li\u003e\n\u003cli\u003eARM Cortex-M0 204MHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eCommunication\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eInterface RS485 half duplex\u003c\/li\u003e\n\u003cli\u003eBaud rate: 2400 to 115200 bps\u003c\/li\u003e\n\u003cli\u003e2xEthernet with built in switch\u003c\/li\u003e\n\u003cli\u003e1-Wire Interface\u003c\/li\u003e\n\u003cli\u003eMicro SD card slot\u003c\/li\u003e\n\u003cli\u003eUSB Host Interface\u003c\/li\u003e\n\u003cli\u003eProtocols: Modbus, BACnet, 1-wire, oBIX\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003e24V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eHousing\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eDimension: 106x110x62 mm.\u003c\/li\u003e\n\u003cli\u003eConstruction: plastic, self-extinguishing (PC\/ABS)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting (DIN EN 50022 norm)\u003c\/li\u003e\n\u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eEnvironments\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature: -10¬∞C to 50¬∞C\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40¬∞C to 85¬∞C\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 5 to 95%, no condensation\u003c\/li\u003e\n\u003cli\u003eIngress Protection Rating: IP40 ‚Äì for indoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-AAC20\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-AAC20-D\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-AAC20-D style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-AAC20-D\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-AAC20\/\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37322142843035,"sku":"iSMA-B-AAC20-D","price":888.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/isma-b-aac20-d-600x600.png?v=1737466962"},{"product_id":"isma-b-aac20","title":"iSMA-B-AAC20","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eAAC20 controller (iSMA-B-AAC20) is an advanced device to control building automation and HVAC systems. Use of SVM (Sedona Virtual Machine) allows you to finish the setup quickly and easily. It is ideal for smaller projects where you want to stay open protocol while keeping the development simple and the cost under budget.\u003c\/p\u003e\n\u003cp\u003eWith a large number of inputs and outputs allows integrating with other devices and sensors (AAC20 provides 8xUI, 4xDI, 4\/6xAO and 4xDO). Its fast processor allows controlling of even very large objects. Built-in RS485 can be used to expand the number of I\/O by connecting MINI or MIX series I\/O modules using Modbus ASCII\/RTU. In addition, to increase the versatility of the controller, it supports many open communications protocols like: BACnet, Modbus, SOX, DALI, M-Bus, 1-wire or oBIX (optional). AAC20 is mounted in a housing adapted for DIN rail mounting or directly on a panel. Separate, easy to remove connectors allow quick wiring without removing the entire module.\u003c\/p\u003e\n\u003cstrong\u003eInputs \u0026amp; Outputs\u003c\/strong\u003e\u003cbr\u003e8xUniversal Inputs (8UI)\u003cbr\u003eAll universal inputs have 16-bit resolution which support the following types of inputs:\n\u003cul\u003e\n\u003cli\u003eTemperature input support the following types of sensors: 10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1, Pt1000, Ni1000\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cb\u003eFor sensor Pt1000 and Ni1000 use only 16bit resolution\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage input 0-10VDC: input resistance 100kŒ© accuracy ¬±0,1% measurement resolution 3mV@12bit and 1mV@16bit\u003c\/li\u003e\n\u003cli\u003eCurrent input 0-20mA (external resistor 499Œ© required)\u003c\/li\u003e\n\u003cli\u003eResistive input 0-1000kŒ©: measurement resolution for 20kŒ© load 20Œ©@12bit and 1Œ©@16bit\u003c\/li\u003e\n\u003cli\u003eDry contact input\u003c\/li\u003e\n\u003c\/ul\u003e\n4 x Digital Inputs (4DI)\n\u003cul\u003e\n\u003cli\u003eDry contact inputs\u003c\/li\u003e\n\u003cli\u003eFast pulse counter up to 100Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n4\/6 x Analog Outputs (4\/6AO)\u003cbr\u003eAll analog outputs are equipped with 12-bit ADC provides10 mV resolution and accuracy less than ¬±0,5%. They support the following output types:\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eOutput 0-10V DC maximum load up to 20mA(5mA- AO6)\u003c\/li\u003e\n\u003cli\u003ePWM: 0,01Hz, 0,1Hz, 1Hz, 10Hz, 100Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\nAO5 and AO6 can only be used if 1-wire port is not in use, please notice for AO6 maximum current load is up to 5mA \u003cbr\u003e4 x Digital Outputs (4DO)\n\u003cul\u003e\n\u003cli\u003eRelay output (NO) max. 3A, 250 VAC\/30 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003ePlatform\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eARM Cortex-M4 204MHz\u003c\/li\u003e\n\u003cli\u003eARM Cortex-M0 204MHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eCommunication\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eInterface RS485 half duplex\u003c\/li\u003e\n\u003cli\u003eBaud rate: 2400 to 115200 bps\u003c\/li\u003e\n\u003cli\u003e2xEthernet with built in switch\u003c\/li\u003e\n\u003cli\u003e1-Wire Interface\u003c\/li\u003e\n\u003cli\u003eMicro SD card slot\u003c\/li\u003e\n\u003cli\u003eUSB Host Interface\u003c\/li\u003e\n\u003cli\u003eProtocols: Modbus, BACnet, 1-wire, oBIX\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003ePower supply\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e24V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eHousing\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eDimension: 106x110x62 mm.\u003c\/li\u003e\n\u003cli\u003eConstruction: plastic, self-extinguishing (PC\/ABS)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting (DIN EN 50022 norm)\u003c\/li\u003e\n\u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eEnvironments\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature: -10¬∞C to 50¬∞C\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40¬∞C to 85¬∞C\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 5 to 95%, no condensation\u003c\/li\u003e\n\u003cli\u003eIngress Protection Rating: IP40 ‚Äì for indoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-AAC20\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-AAC20\" target=\"_blank\"\u003e\u003cimg alt=\"Documentation \u0026amp; Downloads for iSMA-B-AAC20 style=\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" none=\"\" float:=\"\"\u003e\u003c\/a\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-AAC20\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-AAC20\/\"\u003e \u003c\/a\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37322143039643,"sku":"iSMA-B-AAC20","price":750.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/isma-b-aac20-600x600.png?v=1737466962"},{"product_id":"isma-b-mix18-ip","title":"iSMA-B-MIX18-IP","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003eOne of the most easy to setup and most flexible IP IO Modules on the market.¬†This module provides the best value per point with the lowest footprint and will make you deliver any BMS project on time and budget.\u003c\/p\u003e\n\u003cp\u003eThe iSMA-B-MIX18 of the MIX series has been designed for building distributed control systems using JACE or AAC20 devices. All the MIX Series modules have been equipped with the most commonly used types of I\/O in building automation (MIX of all types of I\/O in one unit). This module is¬†factory-equipped with the two most popular open communication protocols: Modbus (TCP\/IP) and BACnet (IP), which are selected using DIP switches.¬†\u003cspan\u003eRotary switches are used to set the module address, which facilitates and accelerates the process of commissioning the system. Built-in mini USB allows for the initial configuration of the unit without external power supply.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eBuilt-in Modbus Gateway TCP\/IP to Modbus ASCII\/RTU, enabling you to connect additional modules\/devices that communicate via Modbus RS485.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis module is fully compatible with any Modbus or Bacnet system including the following:¬†\u003c\/span\u003e\u003ca href=\"https:\/\/www.innon.co.uk\/collections\/tridium-io-modules\" title=\"TRIDIUM IO MODULES\" target=\"_blank\"\u003eTridium Jace3, Jace6, Jace8000¬†Compatible\u003c\/a\u003e\u003cspan\u003e,¬†\u003c\/span\u003e\u003ca href=\"https:\/\/www.innon.co.uk\/collections\/trend-io-modules\" title=\"Trend BEMS Compatible IO Modules\" target=\"_blank\"\u003eTrend IQ3, IQ4 Bacnet IP¬†Compatible\u003c\/a\u003e\u003cspan\u003e,¬†\u003c\/span\u003e\u003ca href=\"https:\/\/www.innon.co.uk\/collections\/siemens-io-modules\" title=\"Siemens Bacnet IO Modules\" target=\"_blank\"\u003eSiemens PX range\u003c\/a\u003e\u003cspan\u003e,¬†\u003c\/span\u003e\u003ca href=\"https:\/\/www.innon.co.uk\/collections\/cylon-bacnet-io-modules\" title=\"Cylon Bacnet IO Modules\"\u003eCylon Bacnet controllers\u003c\/a\u003e\u003cspan\u003e,¬†\u003c\/span\u003e\u003ca href=\"https:\/\/www.innon.co.uk\/collections\/schneider-bacnet-io-modules\" title=\"SCHNEIDER BACNET IO MODULES\" target=\"_blank\"\u003eSchneider Electric StruxureWare Bacnet controllers\u003c\/a\u003e\u003cspan\u003e,¬†\u003c\/span\u003e\u003ca href=\"https:\/\/www.innon.co.uk\/collections\/oss-bacnet-ip-io-modules\" title=\"OSS BACNET IP IO MODULES\" target=\"_blank\"\u003eOSS NeOSS building management controller\u003c\/a\u003e\u003cspan\u003e,¬†\u003c\/span\u003e\u003ca href=\"https:\/\/www.innon.co.uk\/collections\/priva-blue-id-bacnet-ip-io-modules\" title=\"PRIVA BLUE ID BACNET IP IO MODULES\" target=\"_blank\"\u003ePriva Blue ID\u003c\/a\u003e\u003cspan\u003e,¬†\u003c\/span\u003e\u003cspan data-sheets-userformat='{\"2\":17153,\"3\":{\"1\":0},\"11\":4,\"12\":0,\"17\":1}' data-sheets-value='{\"1\":2,\"2\":\"Distech\"}'\u003e\u003ca href=\"https:\/\/www.innon.co.uk\/collections\/distech-io-modules\" title=\"DISTECH IO MODULES\"\u003eDistech EC Bos\u003c\/a\u003e,¬†\u003ca href=\"https:\/\/www.innon.co.uk\/collections\/dell-edge-gateway-5000-io-modules\" title=\"DELL EDGE GATEWAY 5000 IO MODULES\" target=\"_blank\"\u003eDELL EDGE GATEWAY 5000\u003c\/a\u003e,¬†\u003ca href=\"https:\/\/www.innon.co.uk\/collections\/honeywell-centraline-io-modules\" title=\"HONEYWELL CENTRALINE IO MODULES\"\u003eCompatible with any Honeywell Centraline Hawk\u003c\/a\u003e,¬†\u003ca href=\"https:\/\/www.innon.co.uk\/collections\/delta-controls-bacnet-ip-io-modules\" title=\"DELTA CONTROLS BACNET IP IO MODULES\"\u003eDelta Controls Compatible IO Modules\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eInputs \u0026amp; Outputs\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e5xUniversal Inputs (5UI)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eAll universal inputs have 16-bit resolution which support the following types of inputs:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature input support the following types of sensors: 10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1, Pt1000, Ni1000\u003c\/li\u003e\n\u003cli\u003eFor sensor Pt1000 and Ni1000 use only 16bit resolution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage input 0-10VDC: input resistance 100kŒ© accuracy ¬±0,1% measurement resolution 3mV@12bit and 1mV@16bit\u003c\/li\u003e\n\u003cli\u003eCurrent input 0-20mA - Required external resistor: 200 Ω, sold separately\u003c\/li\u003e\n\u003cli\u003eResistive input 0-1000kŒ©: measurement resolution for 20kŒ© load 20Œ©@12bit and 1Œ©@16bit\u003c\/li\u003e\n\u003cli\u003eDry contact input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e5xDigital Inputs (5DI)\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDry contact inputs\u003c\/li\u003e\n\u003cli\u003eFast pulse counter up to 100Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e4xAnalog Outputs (4AO)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eAll analog outputs are equipped with 12-bit ADC provides10 mV resolution and accuracy less than ¬±0,5%. They support the following output types:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput 0-10V DC maximum load up to 20mA\u003c\/li\u003e\n\u003cli\u003ePWM: 0,01Hz, 0,1Hz, 1Hz, 10Hz, 100Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e4xDigital Outputs (4DO)\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRelay output (NO) max. 3A, 250 VAC\/30 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlatform\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCortex-M3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInterface RS485 half duplex\u003c\/li\u003e\n\u003cli\u003e2xEthernet with built in switch\u003c\/li\u003e\n\u003cli\u003eUp to 99 devices on the bus\u003c\/li\u003e\n\u003cli\u003eProtocols: MODBUS or BACnet\u003c\/li\u003e\n\u003cli\u003eBaud rate: 2400 to 115200 bps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e24V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDimension: 88x110x62 mm.\u003c\/li\u003e\n\u003cli\u003eConstruction: plastic, self-extinguishing (PC\/ABS)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting (DIN EN 50022 norm)\u003c\/li\u003e\n\u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironments\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature: -10¬∞C to 50¬∞C\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40¬∞C to 85¬∞C\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 5 to 95%, no condensation\u003c\/li\u003e\n\u003cli\u003eIngress Protection Rating: IP40 ‚Äì for indoor installation\u003cstrong\u003e¬†\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-MIX18-IP\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MIX\/\" target=\"_blank\"\u003e\u003cimg style=\"float: none;\" alt=\"Documentation \u0026amp; Downloads for iSMA-B-MIX38\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\"\u003e\u003c\/a\u003e \u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-MIX18-IP\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MIX\/\" target=\"_blank\"\u003e \u003c\/a\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003eIn the \u003ca href=\"http:\/\/support.innon.com\/\" target=\"_blank\"\u003eDOWNLOAD\u003c\/a\u003e session you can find: \u003cbr\u003eThe ISMA driver for Niagara, which contains the ISMA device Palette \u003cbr\u003eISMA configurator which is needed for updating firmware and configure modules\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eFor any help please contact our support \u003ca title=\"Contact Innon Support\" href=\"https:\/\/innon.myshopify.com\/pages\/contact-support\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003cdiv class=\"faq-section\"\u003e\n\u003cdiv class=\"question-v1\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003cdiv class=\"qs-content\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37322143334555,"sku":"iSMA-B-MIX18-IP","price":506.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/isma-b-mix18-ip.png?v=1737466961"},{"product_id":"isma-b-4o-h-ip","title":"iSMA-B-4O-H-IP","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003eMINI modules have been designed to complement the MIX series. Depending on the project needs, one of 7 different MINI can be chosen, all inputs and outputs are unified among our products. One feature that makes these two product groups different is hand operating switches, in some applications, it is required. Moreover, all I\/O modules have \u003c\/span\u003e\u003cstrong\u003eBTL, CE \u003c\/strong\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cstrong\u003eUL \u003c\/strong\u003e\u003cspan\u003ecertificates.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eLike in the case of the MIX modules IP (1x Ethernet), MINI are factory-equipped with the most popular open communication protocols Modbus (TCP\/IP) and BACnet (IP), which are selected using DIP switches. Rotary switches are used to set the module address, which facilitates and accelerates the process of commissioning the system. Built-in mini USB allows for the initial configuration of the unit without external power supply.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eMINI I\/O Modules with Ethernet have built-in Modbus Gateway TCP\/IP to Modbus ASCII\/RTU, enabling you to connect additional modules\/devices that communicate via Modbus RS485.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eiSMA-B-4O-H-IP is one of the most easy to setup and versatile IO modules. Compatible with almost any BMS works on either Bacnet or Modbus. It has 4 Digital Outputs, can be hand operated and works on IP connection.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis module is fully compatible with any Modbus or Bacnet system including the following: Tridium Jace3, Jace6, Jace8000 Compatible, Trend IQ3, IQ4 Bacnet IP Compatible, Siemens PX range, Cylon Bacnet controllers, Schneider Electric StruxureWare Bacnet controllers, OSS NeOSS building management controller, Priva Blue ID, Distech EC Bos, DELL EDGE GATEWAY 5000, Compatible with any Honeywell Centraline Hawk, Delta Controls Compatible IO Modules\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cbr\u003e\u003cstrong\u003eInputs \u0026amp; Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003cbr\u003e\u003cstrong\u003e4x Digital Outputs (4DO)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRelay output (NC\/NO) max. 8A, 250V AC\/30 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlatform\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCortex-M3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInterface RS485 half duplex\u003c\/li\u003e\n\u003cli\u003e1 x Fast Ethernet\u003c\/li\u003e\n\u003cli\u003eUp to 99 devices on the bus\u003c\/li\u003e\n\u003cli\u003eProtocols: MODBUS or BACnet\u003c\/li\u003e\n\u003cli\u003eBaud rate: 2400 to 115200 bps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e24V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDimension: 35x110x62 mm.\u003c\/li\u003e\n\u003cli\u003eConstruction: plastic, self-extinguishing (PC\/ABS)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting (DIN EN 50022 norm)\u003c\/li\u003e\n\u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironments\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature: -10 C to 50 C\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40 C to 85 C\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 5 to 95%, no condensation\u003c\/li\u003e\n\u003cli\u003eIngress Protection Rating: IP40 ‚   for indoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MINI\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-4O-H-IP\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" alt=\"Documentation \u0026amp; Downloads for iSMA-B-4O-H-IP\" style=\"float: none;\"\u003e\u003c\/a\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MINI\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-4O-H-IP\" target=\"_blank\"\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eIn the \u003ca href=\"http:\/\/support.innon.com\/\" target=\"_blank\"\u003eDOWNLOAD\u003c\/a\u003e session you can find: \u003cbr\u003eThe ISMA driver for Niagara, which contains the ISMA device Palette \u003cbr\u003eISMA configurator which is needed for updating firmware and configure modules\u003c\/p\u003e\n\u003cp\u003eFor any help please contact our support \u003ca href=\"https:\/\/innon.myshopify.com\/pages\/contact-support\" title=\"Contact Innon Support\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cbr\u003e\u003c\/h5\u003e\n\u003cdiv class=\"faq-section\"\u003e\n\u003cdiv class=\"question-v1\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003cdiv class=\"qs-content\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37322143432859,"sku":"iSMA-B-4O-H-IP","price":351.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-B-Mini-4O-H-IP-600x600.png?v=1737466960"},{"product_id":"isma-b-4u4a-h-ip","title":"iSMA-B-4U4A-H-IP","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003eMINI modules have been designed to complement the MIX series. Depending on the project needs, one of 7 different MINI can be chosen, all inputs and outputs are unified among our products. One feature that makes these two product groups different is hand operating switches, in some applications, it is required. Moreover, all I\/O modules have \u003c\/span\u003e\u003cstrong\u003eBTL, CE \u003c\/strong\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cstrong\u003eUL\u003c\/strong\u003e\u003cspan\u003e¬†certificates.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eLike in the case of the MIX modules IP (1x Ethernet), MINI are factory-equipped with the most popular open communication protocols Modbus (TCP\/IP) and BACnet (IP), which are selected using DIP switches. Rotary switches are used to set the module address, which facilitates and accelerates the process of commissioning the system. Built-in mini USB allows for the initial configuration of the unit without external power supply.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eMINI I\/O Modules with Ethernet have built-in Modbus Gateway TCP\/IP to Modbus ASCII\/RTU, enabling you to connect additional modules\/devices that communicate via Modbus RS485.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eiSMA-B-4U4A-H-IP is one of the most innovative and easy to setup IO modules on the market. It works on either Bacnet or Modbus and can be hand operated. It has 4 Universal Inputs and 4 Analog Outputs.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis module is fully compatible with any Modbus or Bacnet system including the following: Tridium Jace3, Jace6, Jace8000 Compatible, Trend IQ3, IQ4 Bacnet IP Compatible, Siemens PX range, Cylon Bacnet controllers, Schneider Electric StruxureWare Bacnet controllers, OSS NeOSS building management controller, Priva Blue ID, Distech EC Bos, DELL EDGE GATEWAY 5000, Compatible with any Honeywell Centraline Hawk, Delta Controls Compatible IO Modules\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e Inputs \u0026amp; Outputs:\u003c\/strong\u003e \u003cbr\u003e\u003cstrong\u003e4x Universal Inputs (4UI)\u003c\/strong\u003e All universal inputs have 16-bit resolution which support the following types of inputs:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature input support the following types of sensors: 10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1, Pt1000, Ni1000 \u003cb\u003eFor sensor Pt1000 and Ni1000 use only 16bit resolution\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003eVoltage input 0-10VDC: input resistance 100kŒ© accuracy 0,1% measurement resolution 3mV@12bit and 1mV@16bit\u003c\/li\u003e\n\u003cli\u003eCurrent input 0-20mA - Required external resistor: 200 Ω, sold separately\u003c\/li\u003e\n\u003cli\u003eResistive input 0-1000kŒ©: measurement resolution for 20kŒ© load 20Œ©@12bit and 1Œ©@16bit\u003c\/li\u003e\n\u003cli\u003eDry contact input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e4x Analog Outputs (4AO)\u003c\/strong\u003e All analog outputs are equipped with 12-bit ADC provides10 mV resolution and accuracy less than 0,5%. They support the following output types:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput 0-10V DC maximum load up to 20mA\u003c\/li\u003e\n\u003cli\u003ePWM: 0,01Hz, 0,1Hz, 1Hz, 10Hz, 100Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlatform\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCortex-M3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInterface RS485 half duplex\u003c\/li\u003e\n\u003cli\u003e1 x Fast Ethernet\u003c\/li\u003e\n\u003cli\u003eUp to 99 devices on the bus\u003c\/li\u003e\n\u003cli\u003eProtocols: MODBUS or BACnet\u003c\/li\u003e\n\u003cli\u003eBaud rate: 2400 to 115200 bps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e24V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDimension: 35x110x62 mm.\u003c\/li\u003e\n\u003cli\u003eConstruction: plastic, self-extinguishing (PC\/ABS)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting (DIN EN 50022 norm)\u003c\/li\u003e\n\u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironments\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature: -10C to 50C\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40C to 85C\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 5 to 95%, no condensation\u003c\/li\u003e\n\u003cli\u003eIngress Protection Rating: IP40 ‚for indoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MINI\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-4U4A-H-IP\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" alt=\"Documentation \u0026amp; Downloads for iSMA-B-4U4A-H-IP\" style=\"float: none;\"\u003e\u003c\/a\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MINI\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-4U4A-H-IP\" target=\"_blank\"\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cspan\u003eIn the \u003c\/span\u003e\u003ca href=\"http:\/\/support.innon.com\/\" target=\"_blank\"\u003eDOWNLOAD\u003c\/a\u003e\u003cspan\u003e session you can find:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe ISMA driver for Niagara, which contains the ISMA device Palette\u003c\/li\u003e\n\u003cli\u003eISMA configurator which is needed for updating firmware and configure modules\u003c\/li\u003e\n\u003cli\u003eTemplates for Siemens sensors for Niagara (Generic Tabular) - Ni1000 Ohm at 0¬∞C - PTC T1 (Resistance\/Voltage) - Pt100 Ohm at 0¬∞C - Pt1000 Ohm at 0¬∞C - Pt1000 Ohm at 0¬∞C - Pt1000 Ohm at 0¬∞C - Pt1000 Ohm at 0¬∞C - Pt1000 Ohm at 0¬∞C¬† -¬†¬†¬† Ni100 Ohm at 0¬∞C - Ni100 Ohm at 20¬∞C - NTC 107 Ohm at 20¬∞C - NTC 150 Ohm at 31¬∞C - NTC 1 kOhm at 20¬∞C - NTC 1 kOhm at 20¬∞C - NTC 2 kOhm at 20¬∞C - NTC 3850 Ohm at 0¬∞C - NTC 500 Ohm at 20¬∞C - NTC 575 Ohm at 20¬∞C - NTC 8250 Ohm at 19¬∞C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003eFor any help please contact our support \u003ca href=\"\/pages\/contact-support\" title=\"Contact Innon Support\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ch5\u003e\u003cbr\u003e\u003c\/h5\u003e\n\u003cdiv class=\"faq-section\"\u003e\n\u003cdiv class=\"question-v1\"\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003cdiv class=\"qs-content\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37322143596699,"sku":"iSMA-B-4U4A-H-IP","price":399.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-B-Mini-4U4A-H-IP-600x600.png?v=1737466960"},{"product_id":"isma-b-4u4o-h-ip","title":"iSMA-B-4U4O-H-IP","description":"\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003eMINI modules have been designed to complement the MIX series. Depending on the project needs, one of 7 different MINI can be chosen, all inputs and outputs are unified among our products. One feature that makes these two product groups different is hand operating switches, in some applications, it is required. Moreover, all I\/O modules have \u003c\/span\u003e\u003cstrong\u003eBTL, CE \u003c\/strong\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cstrong\u003eUL \u003c\/strong\u003e\u003cspan\u003ecertificates.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eLike in the case of the MIX modules IP (1x Ethernet), MINI are factory-equipped with the most popular open communication protocols Modbus (TCP\/IP) and BACnet (IP), which are selected using DIP switches. Rotary switches are used to set the module address, which facilitates and accelerates the process of commissioning the system. Built-in mini USB allows for the initial configuration of the unit without external power supply.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eMINI I\/O Modules with Ethernet have built-in Modbus Gateway TCP\/IP to Modbus ASCII\/RTU, enabling you to connect additional modules\/devices that communicate via Modbus RS485.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eiSMA-B-4U4O-H-IP is one of the most innovative and easy to setup IO module on the market. Works on either Bacnet or Modbus. It has 4 Universal Inputs and 4 Digital Outputs and can be hand operated.\u003c\/p\u003e\n\u003cp\u003eThis module is fully compatible with any Modbus or Bacnet system including the following: Tridium Jace3, Jace6, Jace8000 Compatible, Trend IQ3, IQ4 Bacnet IP Compatible, Siemens PX range, Cylon Bacnet controllers, Schneider Electric StruxureWare Bacnet controllers, OSS NeOSS building management controller, Priva Blue ID, Distech EC Bos, DELL EDGE GATEWAY 5000, Compatible with any Honeywell Centraline Hawk, Delta Controls Compatible IO Modules\u003c\/p\u003e\n\u003ch3\u003e4x Universal inputs (4UI)\u003c\/h3\u003e\n\u003cp\u003eAll universal inputs have 16-bit resolution which support the following types of inputs:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature input support the following types of sensors: 10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1, Pt1000, Ni1000 \u003cb\u003eFor sensor Pt1000 and Ni1000 use only 16bit resolution\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003eVoltage input 0-10VDC: input resistance 100kŒ© accuracy 0,1% measurement resolution 3mV@12bit and 1mV@16bit\u003c\/li\u003e\n\u003cli\u003eCurrent input 0-20mA - Required external resistor: 200 Ω, sold separately\u003c\/li\u003e\n\u003cli\u003eResistive input 0-1000kŒ©: measurement resolution for 20kŒ© load 20Œ©@12bit and 1Œ©@16bit\u003c\/li\u003e\n\u003cli\u003eDry contact input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e4x Digital Outputs (4DO)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRelay output (NO) max. 3A, 250V AC\/30 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlatform\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCortex-M3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommunication\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInterface RS485 half duplex\u003c\/li\u003e\n\u003cli\u003e1 x Fast Ethernet\u003c\/li\u003e\n\u003cli\u003eUp to 99 devices on the bus\u003c\/li\u003e\n\u003cli\u003eProtocols: MODBUS or BACnet\u003c\/li\u003e\n\u003cli\u003eBaud rate: 2400 to 115200 bps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePower supply\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e24V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHousing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDimension: 35x110x62 mm.\u003c\/li\u003e\n\u003cli\u003eConstruction: plastic, self-extinguishing (PC\/ABS)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting (DIN EN 50022 norm)\u003c\/li\u003e\n\u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature: -10C to 50C\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40C to 85C\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 5 to 95%, no condensation\u003c\/li\u003e\n\u003cli\u003eIngress Protection Rating: IP40 ‚ for indoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e \u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MINI\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-4U4O-H-IP\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" alt=\"Documentation \u0026amp; Downloads for iSMA-B-4U4O-H-IP\" style=\"float: none;\"\u003e\u003c\/a\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MINI\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-4U4O-H-IP\" target=\"_blank\"\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eIn the \u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"http:\/\/support.innon.com\/\" style=\"color: #0000ff;\"\u003eDOWNLOAD\u003c\/a\u003e\u003c\/span\u003e session you can find:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe ISMA driver for Niagara, which contains the ISMA device Palette\u003c\/li\u003e\n\u003cli\u003eIsma configurator which is needed for updating firmware and configure modules\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"http:\/\/support.innon.com\/Tridium_Niagara\/Sensor_Templates_for_Niagara-Generic_Tabular\/\" style=\"color: #0000ff;\"\u003eTemplates\u003c\/a\u003e\u003c\/span\u003e for Siemens sensors for Niagara (Generic Tabular) - Ni1000 Ohm at 0C - PTC T1 (Resistance\/Voltage) - Pt100 Ohm at 0¬∞C - Pt1000 Ohm at 0C - Pt1000 Ohm at 0¬∞C - Pt1000 Ohm at 0¬∞C - Pt1000 Ohm at 0¬∞C - Pt1000 Ohm at 0¬∞C¬† -¬†¬†¬† Ni100 Ohm at 0¬∞C - Ni100 Ohm at 20¬∞C - NTC 107 Ohm at 20¬∞C - NTC 150 Ohm at 31¬∞C - NTC 1 kOhm at 20¬∞C - NTC 1 kOhm at 20¬∞C - NTC 2 kOhm at 20¬∞C - NTC 3850 Ohm at 0¬∞C - NTC 500 Ohm at 20¬∞C - NTC 575 Ohm at 20¬∞C - NTC 8250 Ohm at 19¬∞C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"faq-section\"\u003e\n\u003cdiv class=\"question-v1\"\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003cdiv class=\"qs-content\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37322143793307,"sku":"iSMA-B-4U4O-H-IP","price":384.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-B-Mini-4U4O-H-IP-600x600.png?v=1737466959"},{"product_id":"isma-b-4i4o-h-ip","title":"iSMA-B-4I4O-H-IP","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003eMINI modules have been designed to complement the MIX series. Depending on the project needs, one of 7 different MINI can be chosen, all inputs and outputs are unified among our products. One feature that makes these two product groups different is hand operating switches, in some applications, it is required. Moreover, all I\/O modules have \u003c\/span\u003e\u003cstrong\u003eBTL, CE \u003c\/strong\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cstrong\u003eUL \u003c\/strong\u003e\u003cspan\u003ecertificates.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eLike in the case of the MIX modules IP (1x Ethernet), MINI are factory-equipped with the most popular open communication protocols Modbus (TCP\/IP) and BACnet (IP), which are selected using DIP switches. Rotary switches are used to set the module address, which facilitates and accelerates the process of commissioning the system. Built-in mini USB allows for the initial configuration of the unit without external power supply.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eMINI I\/O Modules with Ethernet have built-in Modbus Gateway TCP\/IP to Modbus ASCII\/RTU, enabling you to connect additional modules\/devices that communicate via Modbus RS485.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eISMA-B-4I4O-H-IP is one of the most easy to setup and versatile IO modules. Compatible with almost any BMS works on either Bacnet or Modbus. It has 4 Digital Inputs and 4 Digital Outputs and can be hand operated.\u003c\/p\u003e\n\u003cp\u003eThis module is fully compatible with any Modbus or Bacnet system including the following: Tridium Jace3, Jace6, Jace8000 Compatible, Trend IQ3, IQ4 Bacnet IP Compatible, Siemens PX range, Cylon Bacnet controllers, Schneider Electric StruxureWare Bacnet controllers, OSS NeOSS building management controller, Priva Blue ID, Distech EC Bos, DELL EDGE GATEWAY 5000, Compatible with any Honeywell Centraline Hawk, Delta Controls Compatible IO Modules\u003c\/p\u003e\n\u003cp\u003eIn addition this module has inbuilt On\/Off Logic for lighting application with Dali Systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInputs \u0026amp; Outputs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e4 x Digital Inputs (4DI)\u003c\/li\u003e\n\u003cli\u003eDry contact inputs\u003c\/li\u003e\n\u003cli\u003eFast pulse counter up to 100Hz\u003c\/li\u003e\n\u003cli\u003e4 x Digital Outputs (4DO)\u003c\/li\u003e\n\u003cli\u003eRelay output (NO) max. 3A, 250V AC\/30 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlatform:\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCortex-M3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication:\u003cbr\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003eInterface RS485 half duplex \u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Fast Ethernet\u003c\/li\u003e\n\u003cli\u003eUp to 99 devices on the bus\u003c\/li\u003e\n\u003cli\u003eProtocols: MODBUS or BACnet\u003c\/li\u003e\n\u003cli\u003eBaud rate: 2400 to 115200 bps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePower supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e24V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHousing:\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDimension: 35x110x62 mm.\u003c\/li\u003e\n\u003cli\u003eConstruction: plastic, self-extinguishing (PC\/ABS)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting (DIN EN 50022 norm)\u003c\/li\u003e\n\u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironments:\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature: -10C to 50C\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40C to 85C\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 5 to 95%, no condensation\u003c\/li\u003e\n\u003cli\u003eIngress Protection Rating: IP40‚ for indoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eDo you have a question about this product?\u003c\/h5\u003e\n\u003cp\u003e\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MINI\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-4I4O-H-IP\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" alt=\"Documentation \u0026amp; Downloads for iSMA-B-4I4O-H-IP\" style=\"float: none;\"\u003e\u003c\/a\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MINI\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-4I4O-H-IP\" target=\"_blank\"\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eIn the \u003ca href=\"http:\/\/support.innon.com\" target=\"_blank\"\u003eDOWNLOAD\u003c\/a\u003e session you can find: \u003cbr\u003eThe ISMA driver for Niagara, which contains the ISMA device Palette \u003cbr\u003eISMA configurator which is needed for updating firmware and configure modules\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37322143957147,"sku":"iSMA-B-4I4O-H-IP","price":351.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-B-Mini-4I4O-H-IP-600x600.png?v=1737466958"},{"product_id":"isma-b-8u-ip","title":"iSMA-B-8U-IP","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003eMINI modules have been designed to complement the MIX series. Depending on the project needs, one of 7 different MINI can be chosen, all inputs and outputs are unified among our products. One feature that makes these two product groups different is hand operating switches, in some applications, it is required. Moreover, all I\/O modules have \u003c\/span\u003e\u003cstrong\u003eBTL, CE \u003c\/strong\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cstrong\u003eUL \u003c\/strong\u003e\u003cspan\u003ecertificates.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eLike in the case of the MIX modules IP (1x Ethernet), MINI are factory-equipped with the most popular open communication protocols Modbus (TCP\/IP) and BACnet (IP), which are selected using DIP switches. Rotary switches are used to set the module address, which facilitates and accelerates the process of commissioning the system. Built-in mini USB allows for the initial configuration of the unit without external power supply.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eMINI I\/O Modules with Ethernet have built-in Modbus Gateway TCP\/IP to Modbus ASCII\/RTU, enabling you to connect additional modules\/devices that communicate via Modbus RS485.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eiSMA-B-8U-IP is one of the most innovative and easy to setup IO Modules. Works on either Bacnet or Modbus protocols. It has 8 Universal inputs giving you the best cost per point.\u003c\/p\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis module is fully compatible with any Modbus or Bacnet system including the following: Tridium Jace3, Jace6, Jace8000 Compatible, Trend IQ3, IQ4 Bacnet IP Compatible, Siemens PX range, Cylon Bacnet controllers, Schneider Electric StruxureWare Bacnet controllers, OSS NeOSS building management controller, Priva Blue ID, Distech EC Bos, DELL EDGE GATEWAY 5000, Compatible with any Honeywell Centraline Hawk, Delta Controls Compatible IO Modules\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eInputs \u0026amp; Outputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e8x Universal Inputs (8UI)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eAll universal inputs have 16-bit resolution which support the following types of inputs:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature input support the following types of sensors: 10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1, Pt1000, Ni1000 \u003cb\u003eFor sensor Pt1000 and Ni1000 use only 16bit resolution\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003eVoltage input 0-10VDC: input resistance 100kŒ© accuracy ±0,1% measurement resolution 3mV@12bit and 1mV@16bit\u003c\/li\u003e\n\u003cli\u003eCurrent input 0-20mA - Required external resistor: 200 Ω, sold separately\u003c\/li\u003e\n\u003cli\u003eResistive input 0-1000kŒ©: measurement resolution for 20kŒ© load 20Œ©@12bit and 1Œ©@16bit\u003c\/li\u003e\n\u003cli\u003eDry contact input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlatform\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCortex-M3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Fast Ethernet\u003c\/li\u003e\n\u003cli\u003eInterface RS485 half duplex\u003c\/li\u003e\n\u003cli\u003eUp to 99 devices on the bus\u003c\/li\u003e\n\u003cli\u003eProtocols: MODBUS or BACnet\u003c\/li\u003e\n\u003cli\u003eBaud rate: 2400 to 115200 bps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e24V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDimension: 35x110x62 mm.\u003c\/li\u003e\n\u003cli\u003eConstruction: plastic, self-extinguishing (PC\/ABS)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting (DIN EN 50022 norm)\u003c\/li\u003e\n\u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironments\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature: -10C to 50C\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40C to 85C\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 5 to 95%, no condensation\u003c\/li\u003e\n\u003cli\u003eIngress Protection Rating: IP40‚ for indoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cscript src=\"\/\/js.hsforms.net\/forms\/v2.js\" type=\"text\/javascript\" charset=\"utf-8\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e\u003c\/p\u003e\n\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-8U-IP\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MINI\/\" target=\"_blank\"\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg style=\"float: none;\" alt=\"Documentation \u0026amp; Downloads for iSMA-B-8U-IP\" src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\"\u003e\u003c\/div\u003e\n\u003c\/a\u003e\n\u003cp\u003e\u003ca title=\"Documentation \u0026amp; Downloads for iSMA-B-8U-IP\" href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MINI\/\" target=\"_blank\"\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eIn the \u003ca href=\"http:\/\/support.innon.com\/\" target=\"_blank\"\u003eDOWNLOAD\u003c\/a\u003e session you can find: \u003cbr\u003eThe ISMA driver for Niagara, which contains the ISMA device Palette \u003cbr\u003eISMA configurator which is needed for updating firmware and configure modules\u003c\/p\u003e\n\u003cp\u003eFor any help please contact our support \u003ca title=\"Contact Innon Support\" href=\"https:\/\/innon.myshopify.com\/pages\/contact-support\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37322144284827,"sku":"iSMA-B-8U-IP","price":384.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-B-Mini-8U-IP-600x600.png?v=1737466957"},{"product_id":"isma-b-8i-ip","title":"iSMA-B-8I-IP","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003eMINI modules have been designed to complement the MIX series. Depending on the project needs, one of 7 different MINI can be chosen, all inputs and outputs are unified among our products. One feature that makes these two product groups different is hand operating switches, in some applications, it is required. Moreover, all I\/O modules have \u003c\/span\u003e\u003cstrong\u003eBTL, CE \u003c\/strong\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cstrong\u003eUL \u003c\/strong\u003e\u003cspan\u003ecertificates.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eLike in the case of the MIX modules IP (1x Ethernet), MINI are factory-equipped with the most popular open communication protocols Modbus (TCP\/IP) and BACnet (IP), which are selected using DIP switches. Rotary switches are used to set the module address, which facilitates and accelerates the process of commissioning the system. Built-in mini USB allows for the initial configuration of the unit without external power supply.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eMINI I\/O Modules with Ethernet have built-in Modbus Gateway TCP\/IP to Modbus ASCII\/RTU, enabling you to connect additional modules\/devices that communicate via Modbus RS485.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eiSMA-B-8I-IP is one of the most easy to setup and versatile IO modules. Compatible with almost any BMS works on either Bacnet or Modbus. It has 8 Digital Inputs and works on IP connection.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis module is fully compatible with any Modbus or Bacnet system including the following: \u003c\/span\u003e\u003ca title=\"TRIDIUM IO MODULES\" href=\"https:\/\/www.innon.co.uk\/collections\/tridium-io-modules\" target=\"_blank\"\u003eTridium Jace3, Jace6, Jace8000 Compatible\u003c\/a\u003e\u003cspan\u003e, \u003c\/span\u003e\u003ca title=\"Trend BEMS Compatible IO Modules\" href=\"https:\/\/www.innon.co.uk\/collections\/trend-io-modules\" target=\"_blank\"\u003eTrend IQ3, IQ4 Bacnet IP Compatible\u003c\/a\u003e\u003cspan\u003e, \u003c\/span\u003e\u003ca title=\"Siemens Bacnet IO Modules\" href=\"https:\/\/www.innon.co.uk\/collections\/siemens-io-modules\" target=\"_blank\"\u003eSiemens PX range\u003c\/a\u003e\u003cspan\u003e, \u003c\/span\u003e\u003ca title=\"Cylon Bacnet IO Modules\" href=\"https:\/\/www.innon.co.uk\/collections\/cylon-bacnet-io-modules\"\u003eCylon Bacnet controllers\u003c\/a\u003e\u003cspan\u003e, \u003c\/span\u003e\u003ca title=\"SCHNEIDER BACNET IO MODULES\" href=\"https:\/\/www.innon.co.uk\/collections\/schneider-bacnet-io-modules\" target=\"_blank\"\u003eSchneider Electric StruxureWare Bacnet controllers\u003c\/a\u003e\u003cspan\u003e, \u003c\/span\u003e\u003ca title=\"OSS BACNET IP IO MODULES\" href=\"https:\/\/www.innon.co.uk\/collections\/oss-bacnet-ip-io-modules\" target=\"_blank\"\u003eOSS NeOSS building management controller\u003c\/a\u003e\u003cspan\u003e, \u003c\/span\u003e\u003ca title=\"PRIVA BLUE ID BACNET IP IO MODULES\" href=\"https:\/\/www.innon.co.uk\/collections\/priva-blue-id-bacnet-ip-io-modules\" target=\"_blank\"\u003ePriva Blue ID\u003c\/a\u003e\u003cspan\u003e, \u003c\/span\u003e\u003cspan data-sheets-value='{\"1\":2,\"2\":\"Distech\"}' data-sheets-userformat='{\"2\":17153,\"3\":{\"1\":0},\"11\":4,\"12\":0,\"17\":1}'\u003e\u003ca title=\"DISTECH IO MODULES\" href=\"https:\/\/www.innon.co.uk\/collections\/distech-io-modules\"\u003eDistech EC Bos\u003c\/a\u003e, \u003ca title=\"DELL EDGE GATEWAY 5000 IO MODULES\" href=\"https:\/\/www.innon.co.uk\/collections\/dell-edge-gateway-5000-io-modules\" target=\"_blank\"\u003eDELL EDGE GATEWAY 5000\u003c\/a\u003e, \u003ca title=\"HONEYWELL CENTRALINE IO MODULES\" href=\"https:\/\/www.innon.co.uk\/collections\/honeywell-centraline-io-modules\"\u003eCompatible with any Honeywell Centraline Hawk\u003c\/a\u003e, \u003ca title=\"DELTA CONTROLS BACNET IP IO MODULES\" href=\"https:\/\/www.innon.co.uk\/collections\/delta-controls-bacnet-ip-io-modules\"\u003eDelta Controls Compatible IO Modules\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInputs \u0026amp; Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003cbr\u003e\u003cstrong\u003e8x Digital Inputs (8DI)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDry contact inputs\u003c\/li\u003e\n\u003cli\u003eFast pulse counter up to 100Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlatform\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCortex-M3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Fast Ethernet\u003c\/li\u003e\n\u003cli\u003eInterface RS485 half duplex\u003c\/li\u003e\n\u003cli\u003eUp to 99 devices on the bus\u003c\/li\u003e\n\u003cli\u003eProtocols: MODBUS or BACnet\u003c\/li\u003e\n\u003cli\u003eBaud rate: 2400 to 115200 bps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e24V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDimension: 35x110x62 mm.\u003c\/li\u003e\n\u003cli\u003eConstruction: plastic, self-extinguishing (PC\/ABS)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting (DIN EN 50022 norm)\u003c\/li\u003e\n\u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironments\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature: -10C to 50C\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40C to 85C\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 5 to 95%, no condensation\u003c\/li\u003e\n\u003cli\u003eIngress Protection Rating: IP40 ‚for indoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MINI\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-8I-IP\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" alt=\"Documentation \u0026amp; Downloads for iSMA-B-MINI\" style=\"float: none;\"\u003e\u003c\/a\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MINI\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-8I-IP\" target=\"_blank\"\u003e \u003c\/a\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eIn the \u003ca href=\"http:\/\/support.innon.com\/\" target=\"_blank\"\u003eDOWNLOAD\u003c\/a\u003e session you can find: \u003cbr\u003eThe ISMA driver for Niagara, which contains the ISMA device Palette \u003cbr\u003eISMA configurator which is needed for updating firmware and configure modules\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eFor any help please contact our support \u003ca href=\"https:\/\/innon.myshopify.com\/pages\/contact-support\" title=\"Contact Innon Support\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003cdiv\u003e\n\u003ch5\u003e\u003cbr\u003e\u003c\/h5\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37322144612507,"sku":"iSMA-B-8I-IP","price":291.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-B-Mini-8I-IP-600x600.png?v=1737466957"},{"product_id":"isma-b-4o-h","title":"iSMA-B-4O-H","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003eiSMA-B-4O-H is one of the most easy to setup and versatile IO modules. Compatible with almost any BMS works on either Bacnet or Modbus. It has¬†\u003c\/span\u003e4x Digital Outputs (4DO) and\u003cspan\u003e¬†can be hand operated. Once you purchase one you will be up and running in minutes and safely use it on any project.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003c\/h2\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003eThis module is fully compatible with any Modbus or Bacnet system including the following:¬†\u003c\/span\u003e\u003ca title=\"TRIDIUM IO MODULES\" href=\"https:\/\/www.innon.co.uk\/collections\/tridium-io-modules\" target=\"_blank\"\u003eTridium Jace3, Jace6, Jace8000¬†Compatible\u003c\/a\u003e\u003cspan\u003e,¬†\u003c\/span\u003e\u003ca title=\"Trend BEMS Compatible IO Modules\" href=\"https:\/\/www.innon.co.uk\/collections\/trend-io-modules\" target=\"_blank\"\u003eTrend IQ3, IQ4 Bacnet IP¬†Compatible\u003c\/a\u003e\u003cspan\u003e,¬†\u003c\/span\u003e\u003ca title=\"Siemens Bacnet IO Modules\" href=\"https:\/\/www.innon.co.uk\/collections\/siemens-io-modules\" target=\"_blank\"\u003eSiemens PX range\u003c\/a\u003e\u003cspan\u003e,¬†\u003c\/span\u003e\u003ca title=\"Cylon Bacnet IO Modules\" href=\"https:\/\/www.innon.co.uk\/collections\/cylon-bacnet-io-modules\"\u003eCylon Bacnet controllers\u003c\/a\u003e\u003cspan\u003e,¬†\u003c\/span\u003e\u003ca title=\"SCHNEIDER BACNET IO MODULES\" href=\"https:\/\/www.innon.co.uk\/collections\/schneider-bacnet-io-modules\" target=\"_blank\"\u003eSchneider Electric StruxureWare Bacnet controllers\u003c\/a\u003e\u003cspan\u003e,¬†\u003c\/span\u003e\u003ca title=\"OSS BACNET IP IO MODULES\" href=\"https:\/\/www.innon.co.uk\/collections\/oss-bacnet-ip-io-modules\" target=\"_blank\"\u003eOSS NeOSS building management controller\u003c\/a\u003e\u003cspan\u003e,¬†\u003c\/span\u003e\u003ca title=\"PRIVA BLUE ID BACNET IP IO MODULES\" href=\"https:\/\/www.innon.co.uk\/collections\/priva-blue-id-bacnet-ip-io-modules\" target=\"_blank\"\u003ePriva Blue ID\u003c\/a\u003e\u003cspan\u003e,¬†\u003c\/span\u003e\u003cspan data-sheets-value='{\"1\":2,\"2\":\"Distech\"}' data-sheets-userformat='{\"2\":17153,\"3\":{\"1\":0},\"11\":4,\"12\":0,\"17\":1}'\u003e\u003ca title=\"DISTECH IO MODULES\" href=\"https:\/\/www.innon.co.uk\/collections\/distech-io-modules\"\u003eDistech EC Bos\u003c\/a\u003e,¬†\u003ca title=\"DELL EDGE GATEWAY 5000 IO MODULES\" href=\"https:\/\/www.innon.co.uk\/collections\/dell-edge-gateway-5000-io-modules\" target=\"_blank\"\u003eDELL EDGE GATEWAY 5000\u003c\/a\u003e,¬†\u003ca title=\"HONEYWELL CENTRALINE IO MODULES\" href=\"https:\/\/www.innon.co.uk\/collections\/honeywell-centraline-io-modules\"\u003eCompatible with any Honeywell Centraline Hawk\u003c\/a\u003e,¬†\u003ca title=\"DELTA CONTROLS BACNET IP IO MODULES\" href=\"https:\/\/www.innon.co.uk\/collections\/delta-controls-bacnet-ip-io-modules\"\u003eDelta Controls Compatible IO Modules\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cstrong\u003eInputs \u0026amp; Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eÔªø4x Digital Outputs (4DO)\u003c\/li\u003e\n\u003cli\u003eRelay output (NC\/NO) max. 8A, 250V AC\/30 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003ePlatform\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eCortex-M3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInterface RS485 half duplex\u003c\/li\u003e\n\u003cli\u003eUp to 99 devices on the bus\u003c\/li\u003e\n\u003cli\u003eProtocols: MODBUS or BACnet\u003c\/li\u003e\n\u003cli\u003eBaud rate: 2400 to 115200 bps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e24V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDimension: 35x110x62 mm.\u003c\/li\u003e\n\u003cli\u003eConstruction: plastic, self-extinguishing (PC\/ABS)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting (DIN EN 50022 norm)\u003c\/li\u003e\n\u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironments\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature: -10¬∞C to 50¬∞C\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40¬∞C to 85¬∞C\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 5 to 95%, no condensation\u003c\/li\u003e\n\u003cli\u003eIngress Protection Rating: IP40 ‚Äì for indoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MINI\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-4O-H\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" alt=\"Documentation \u0026amp; Downloads for iSMA-B-4O-H\" style=\"float: none;\"\u003e\u003c\/a\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MINI\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-4O-H\" target=\"_blank\"\u003e \u003c\/a\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch5\u003e\u003cbr\u003e\u003c\/h5\u003e\n\u003cdiv class=\"faq-section\"\u003e\n\u003cdiv class=\"question-v1\"\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003cdiv class=\"qs-content\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37322144841883,"sku":"iSMA-B-4O-H","price":276.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-B-Mini-4O-H-600x600.png?v=1737466956"},{"product_id":"isma-b-4u4a-h","title":"iSMA-B-4U4A-H","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003ch5\u003eAbout the product\u003c\/h5\u003e\niSMA-B-4U4A-H¬†has¬†\u003cstrong\u003e4xUI\u003c\/strong\u003e (Universal Inputs) and \u003cstrong\u003e4xAO\u003c\/strong\u003e (Analog Outputs). UI can work in 5 different modes: temperature, voltage, current, resistance, dry contact. AO are 0-10 V DC with max. \u003cstrong\u003e20 mA\u003c\/strong\u003e load allow direct control of relays (12 V DC) or SSR with PWM support. \u003cbr\u003eThe module is factory-equipped with the two most popular open communication protocols: \u003cstrong\u003eModbus\u003c\/strong\u003e¬†\u003cstrong\u003eASCII\/RTU\u003c\/strong\u003e and\u003cstrong\u003eBACnet\u003c\/strong\u003e¬†\u003cstrong\u003eMSTP\u003c\/strong\u003e, which are selected using DIP switches. \u003cbr\u003eAddressing the modules is via rotary switches, which facilitates and accelerates the process of commissioning the system.\u003cbr\u003e \u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e¬†\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis module is fully compatible with any Modbus or Bacnet system including the following:¬†\u003c\/span\u003e\u003ca title=\"TRIDIUM IO MODULES\" href=\"https:\/\/www.innon.co.uk\/collections\/tridium-io-modules\" target=\"_blank\"\u003eTridium Jace3, Jace6, Jace8000¬†Compatible\u003c\/a\u003e\u003cspan\u003e,¬†\u003c\/span\u003e\u003ca title=\"Trend BEMS Compatible IO Modules\" href=\"https:\/\/www.innon.co.uk\/collections\/trend-io-modules\" target=\"_blank\"\u003eTrend IQ3, IQ4 Bacnet IP¬†Compatible\u003c\/a\u003e\u003cspan\u003e,¬†\u003c\/span\u003e\u003ca title=\"Siemens Bacnet IO Modules\" href=\"https:\/\/www.innon.co.uk\/collections\/siemens-io-modules\" target=\"_blank\"\u003eSiemens PX range\u003c\/a\u003e\u003cspan\u003e,¬†\u003c\/span\u003e\u003ca title=\"Cylon Bacnet IO Modules\" href=\"https:\/\/www.innon.co.uk\/collections\/cylon-bacnet-io-modules\"\u003eCylon Bacnet controllers\u003c\/a\u003e\u003cspan\u003e,¬†\u003c\/span\u003e\u003ca title=\"SCHNEIDER BACNET IO MODULES\" href=\"https:\/\/www.innon.co.uk\/collections\/schneider-bacnet-io-modules\" target=\"_blank\"\u003eSchneider Electric StruxureWare Bacnet controllers\u003c\/a\u003e\u003cspan\u003e,¬†\u003c\/span\u003e\u003ca title=\"OSS BACNET IP IO MODULES\" href=\"https:\/\/www.innon.co.uk\/collections\/oss-bacnet-ip-io-modules\" target=\"_blank\"\u003eOSS NeOSS building management controller\u003c\/a\u003e\u003cspan\u003e,¬†\u003c\/span\u003e\u003ca title=\"PRIVA BLUE ID BACNET IP IO MODULES\" href=\"https:\/\/www.innon.co.uk\/collections\/priva-blue-id-bacnet-ip-io-modules\" target=\"_blank\"\u003ePriva Blue ID\u003c\/a\u003e\u003cspan\u003e,¬†\u003c\/span\u003e\u003cspan data-sheets-value='{\"1\":2,\"2\":\"Distech\"}' data-sheets-userformat='{\"2\":17153,\"3\":{\"1\":0},\"11\":4,\"12\":0,\"17\":1}'\u003e\u003ca title=\"DISTECH IO MODULES\" href=\"https:\/\/www.innon.co.uk\/collections\/distech-io-modules\"\u003eDistech EC Bos\u003c\/a\u003e,¬†\u003ca title=\"DELL EDGE GATEWAY 5000 IO MODULES\" href=\"https:\/\/www.innon.co.uk\/collections\/dell-edge-gateway-5000-io-modules\" target=\"_blank\"\u003eDELL EDGE GATEWAY 5000\u003c\/a\u003e,¬†\u003ca title=\"HONEYWELL CENTRALINE IO MODULES\" href=\"https:\/\/www.innon.co.uk\/collections\/honeywell-centraline-io-modules\"\u003eCompatible with any Honeywell Centraline Hawk\u003c\/a\u003e,¬†\u003ca title=\"DELTA CONTROLS BACNET IP IO MODULES\" href=\"https:\/\/www.innon.co.uk\/collections\/delta-controls-bacnet-ip-io-modules\"\u003eDelta Controls Compatible IO Modules\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cstrong\u003eInputs \u0026amp; Outputs\u003c\/strong\u003e \u003cstrong\u003e\u003cbr\u003e4x Universal Inputs (4UI)\u003c\/strong\u003e\u003cbr\u003eAll universal inputs have 16-bit resolution which support the following types of inputs:\n\u003cul\u003e\n\u003cli\u003eTemperature input support the following types of sensors: 10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1, Pt1000, Ni1000 \u003cb\u003eFor sensor Pt1000 and Ni1000 use only 16bit resolution\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003eVoltage input 0-10VDC: input resistance 100kŒ© accuracy ¬±0,1% measurement resolution 3mV@12bit and 1mV@16bit\u003c\/li\u003e\n\u003cli\u003eCurrent input 0-20mA - Required external resistor: 200 Ω, sold separately\u003c\/li\u003e\n\u003cli\u003eResistive input 0-1000kŒ©: measurement resolution for 20kŒ© load 20Œ©@12bit and 1Œ©@16bit\u003c\/li\u003e\n\u003cli\u003eDry contact input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e4x Analog Outputs (4AO)\u003c\/strong\u003e \u003cbr\u003eAll analog outputs are equipped with 12-bit ADC provides10 mV resolution and accuracy less than ¬±0,5%. They support the following output types:\n\u003cul\u003e\n\u003cli\u003eOutput 0-10V DC maximum load up to 20mA\u003c\/li\u003e\n\u003cli\u003ePWM: 0,01Hz, 0,1Hz, 1Hz, 10Hz, 100Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003ePlatform\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eCortex-M3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eCommunication\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eInterface RS485 half duplex\u003c\/li\u003e\n\u003cli\u003eUp to 99 devices on the bus\u003c\/li\u003e\n\u003cli\u003eProtocols: MODBUS or BACnet\u003c\/li\u003e\n\u003cli\u003eBaud rate: 2400 to 115200 bps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003ePower supply\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e24V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eHousing\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eDimension: 35x110x62 mm.\u003c\/li\u003e\n\u003cli\u003eConstruction: plastic, self-extinguishing (PC\/ABS)\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting (DIN EN 50022 norm)\u003c\/li\u003e\n\u003cli\u003eCooling: internal air circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eEnvironments\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature: -10¬∞C to 50¬∞C\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40¬∞C to 85¬∞C\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 5 to 95%, no condensation\u003c\/li\u003e\n\u003cli\u003eIngress Protection Rating: IP40 ‚Äì for indoor installation\u003cstrong\u003e¬†\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDo you have a question about this product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- [if lte IE 8]\u003e\n\u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"\u003e\u003c\/script\u003e\n\u003c![endif]--\u003e \u003cscript charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"\u003e\u003c\/script\u003e \u003cscript\u003e\n  hbspt.forms.create({\n\tregion: \"na1\",\n\tportalId: \"5694023\",\n\tformId: \"a0bdbc3e-58e9-404f-b0a7-6576bd78c2f6\"\n});\n\u003c\/script\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MINI\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-4U4A-H\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/f.hubspotusercontent20.net\/hubfs\/5694023\/2021%20Branding\/Downloads%20\u0026amp;%20Certification%20700x175.png\" alt=\"Documentation \u0026amp; Downloads for iSMA-B-4U4A-H\" style=\"float: none;\"\u003e\u003c\/a\u003e \u003ca href=\"http:\/\/support.innon.com\/iSMA\/iSMA-B-MINI\/\" title=\"Documentation \u0026amp; Downloads for iSMA-B-4U4A-H\" target=\"_blank\"\u003e \u003c\/a\u003e\n\u003cp\u003eIn the \u003ca href=\"http:\/\/support.innon.com\/\" target=\"_blank\"\u003eDOWNLOAD\u003c\/a\u003e session you can find: \u003cbr\u003eThe ISMA driver for Niagara, which contains the ISMA device Palette \u003cbr\u003eISMA configurator which is needed for updating firmware and configure modules\u003c\/p\u003e\n\u003cp\u003eFor any help please contact our support \u003ca href=\"https:\/\/innon.myshopify.com\/pages\/contact-support\" title=\"Contact Innon Support\" target=\"_blank\"\u003eclick here\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"row row-2\"\u003e\n\u003cdiv class=\"col-md-6 col-sm-6 col-xs-12\"\u003e\n\u003cdiv class=\"question-ship-block\"\u003e\n\u003cdiv\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"iSMA","offers":[{"title":"Default Title","offer_id":37322145071259,"sku":"iSMA-B-4U4A-H","price":322.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/4838\/5947\/products\/ISMA-B-Mini-4U4A-H-600x600.png?v=1737466955"}],"url":"https:\/\/www.innon.fr\/collections\/bacnet.oembed?page=4","provider":"Innon Europe","version":"1.0","type":"link"}